skip to main content


Search for: All records

Creators/Authors contains: "Wang, Jian-Ping"

Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher. Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?

Some links on this page may take you to non-federal websites. Their policies may differ from this site.

  1. Abstract

    To treat diseases associated with vagal nerve control of peripheral organs, it is necessary to selectively activate efferent and afferent fibers in the vagus. As a result of the nerve’s complex anatomy, fiber-specific activation proves challenging. Spatially selective neuromodulation using micromagnetic stimulation(μMS) is showing incredible promise. This neuromodulation technique uses microcoils(μcoils) to generate magnetic fields by powering them with a time-varying current. Following the principles of Faraday’s law of induction, a highly directional electric field is induced in the nerve from the magnetic field. In this study on rodent cervical vagus, a solenoidalμcoil was oriented at an angle to left and right branches of the nerve. The aim of this study was to measure changes in the mean arterial pressure (MAP) and heart rate (HR) followingμMS of the vagus. Theμcoils were powered by a single-cycle sinusoidal current varying in pulse widths(PW = 100, 500, and 1000μsec) at a frequency of 20 Hz. Under the influence of isoflurane,μMS of the left vagus at 1000μsec PW led to an average drop in MAP of 16.75 mmHg(n = 7). In contrast,μMS of the right vagus under isoflurane resulted in an average drop of 11.93 mmHg in the MAP(n = 7). Surprisingly, there were no changes in HR to either right or left vagalμMS suggesting the drop in MAP associated with vagusμMS was the result of stimulation of afferent, but not efferent fibers. In urethane anesthetized rats, no changes in either MAP or HR were observed uponμMS of the right or left vagus(n = 3). These findings suggest the choice of anesthesia plays a key role in determining the efficacy ofμMS on the vagal nerve. Absence of HR modulation uponμMS could offer alternative treatment options using VNS with fewer heart-related side-effects.

     
    more » « less
  2. Using in situ atomic-resolution scanning transmission electron microscopy, atomic movements and rearrangements associated with diffusive solid to solid phase transformations in the Pt−Sn system are captured to reveal details of the underlying atomistic mechanisms that drive these transformations. In the PtSn4 to PtSn2 phase transformation, a periodic superlattice substructure and a unique intermediate structure precede the nucleation and growth of the PtSn2 phase. At the atomic level, all stages of the transformation are templated by the anisotropic crystal structure of the parent PtSn4 phase. In the case of the PtSn2 to Pt2Sn3 transformation, the anisotropy in the structure of product Pt2Sn3 dictates the path of transformation. Analysis of atomic configurations at the transformation front elucidates the diffusion pathways and lattice distortions required for these phase transformations. Comparison of multiple Pt−Sn phase transformations reveals the structural parameters governing solid to solid phase transformations in this technologically interesting intermetallic system. 
    more » « less
    Free, publicly-accessible full text available August 23, 2024
  3. Abstract

    Anisotropic planar polaritons - hybrid electromagnetic modes mediated by phonons, plasmons, or excitons - in biaxial two-dimensional (2D) van der Waals crystals have attracted significant attention due to their fundamental physics and potential nanophotonic applications. In this Perspective, we review the properties of planar hyperbolic polaritons and the variety of methods that can be used to experimentally tune them. We argue that such natural, planar hyperbolic media should be fairly common in biaxial and uniaxial 2D and 1D van der Waals crystals, and identify the untapped opportunities they could enable for functional (i.e. ferromagnetic, ferroelectric, and piezoelectric) polaritons. Lastly, we provide our perspectives on the technological applications of such planar hyperbolic polaritons.

     
    more » « less
  4. Understanding the mechanisms of unidirectional magnetoresistance (UMR) has become an important topic for its potential application of a two-terminal spin–orbit torque device. Field sweep DC measurements have been proposed and adopted to measure the value of UMR instead of second harmonic measurements. In this paper, potential measurement errors in conventional DC measurements are investigated. Oersted field and field-like torque usually do not influence the measurement, but a large field-like torque was found to lead to an anisotropic magnetoresistance difference when the sample is not perfectly aligned with the external field. The existence of ordinary magnetoresistance was also found to contribute to a large background. In this paper, an alternative measurement method for UMR was proposed and demonstrated to address those issues related to previous DC measurements. Our work may broaden the understanding of the error sources of UMR measurements and provide a reliable DC measurement method for the characterization of UMR. 
    more » « less
  5. Abstract

    Nb and its compounds are widely used in quantum computing due to their high superconducting transition temperatures and high critical fields. Devices that combine superconducting performance and spintronic non-volatility could deliver unique functionality. Here we report the study of magnetic tunnel junctions with Nb as the heavy metal layers. An interfacial perpendicular magnetic anisotropy energy density of 1.85 mJ/m2was obtained in Nb/CoFeB/MgO heterostructures. The tunneling magnetoresistance was evaluated in junctions with different thickness combinations and different annealing conditions. An optimized magnetoresistance of 120% was obtained at room temperature, with a damping parameter of 0.011 determined by ferromagnetic resonance. In addition, spin-transfer torque switching has also been successfully observed in these junctions with a quasistatic switching current density of 7.3$$\times \;10^{5}$$×105A/cm2.

     
    more » « less
  6. Abstract

    Objective.The objective of this study was to investigate the effects of micromagnetic stimuli strength and frequency from theMagneticPen(MagPen) on the rat right sciatic nerve. The nerve’s response was measured by recording muscle activity and movement of the right hind limb.Approach.The MagPen was custom-built to be stably held over the sciatic nerve. Rat leg muscle twitches were captured on video, and movements were extracted using image processing algorithms. EMG recordings were also used to measure muscle activity.Main results.The MagPen prototype, when driven by an alternating current, generates a time-varying magnetic field, which, according to Faraday’s law of electromagnetic induction, induces an electric field for neuromodulation. The orientation-dependent spatial contour maps of the induced electric field from the MagPen prototype have been numerically simulated. Furthermore, in thisin vivowork onµMS, a dose-response relationship has been reported by experimentally studying how varying the amplitude (Range: 25 mVp-pthrough 6Vp-p) and frequency (range: 100 Hz through 5 kHz) of the MagPen stimuli alters hind limb movement. The primary highlight of this dose-response relationship (repeated overnrats, wheren= 7) is that for aµMS stimuli of higher frequency, significantly smaller amplitudes can trigger hind limb muscle twitch. This frequency-dependent activation can be justified by Faraday’s Law, which states that the magnitude of the induced electric field is directly proportional to the frequency.Significance.This work reports thatµMS can successfully activate the sciatic nerve in a dose-dependent manner. The impact of this dose-response curve addresses the controversy in this research community about whether the stimulation from theseμcoils arise from a thermal effect or micromagnetic stimulation. MagPen probes do not have a direct electrochemical interface with tissue and therefore do not experience electrode degradation, biofouling, and irreversible redox reactions like traditional direct contact electrodes. Magnetic fields from theμcoils create more precise activation than electrodes because they apply more focused and localized stimulation. Finally, unique features ofµMS, such as the orientation dependence, directionality, and spatial specificity, have been discussed.

     
    more » « less
  7. Unidirectional spin Hall magnetoresistance (USMR) is a magnetoresistance effect with potential applications to read two-terminal spin–orbit-torque (SOT) devices directly. In this work, we observed a large USMR value (up to 0.7 × 10 −11 per A/cm 2 , 50% larger than reported values from heavy metals) in sputtered amorphous PtSn 4 /CoFeB bilayers. Ta/CoFeB bilayers with interfacial MgO insertion layers are deposited as control samples. The control experiments show that increasing the interfacial resistance can increase the USMR value, which is the case in PtSn 4 /CoFeB bilayers. The observation of a large USMR value in an amorphous spin–orbit-torque material has provided an alternative pathway for USMR application in two-terminal SOT devices. 
    more » « less