- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources1
- Resource Type
-
0000000001000000
- More
- Availability
-
10
- Author / Contributor
- Filter by Author / Creator
-
-
Entezari, Alireza (1)
-
Shu, Ziyu (1)
-
#Tyler Phillips, Kenneth E. (0)
-
#Willis, Ciara (0)
-
& Abreu-Ramos, E. D. (0)
-
& Abramson, C. I. (0)
-
& Abreu-Ramos, E. D. (0)
-
& Adams, S.G. (0)
-
& Ahmed, K. (0)
-
& Ahmed, Khadija. (0)
-
& Aina, D.K. Jr. (0)
-
& Akcil-Okan, O. (0)
-
& Akuom, D. (0)
-
& Aleven, V. (0)
-
& Andrews-Larson, C. (0)
-
& Archibald, J. (0)
-
& Arnett, N. (0)
-
& Arya, G. (0)
-
& Attari, S. Z. (0)
-
& Ayala, O. (0)
-
- Filter by Editor
-
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
(submitted - in Review for IEEE ICASSP-2024) (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Abstract PurposeForward and backprojections are the basis of all model‐based iterative reconstruction (MBIR) methods. However, computing these accurately is time‐consuming. In this paper, we present a method for MBIR in parallel X‐ray beam geometry that utilizes a Gram filter to efficiently implement forward and backprojection. MethodsWe propose using voxel‐basis and modeling its footprint in a box spline framework to calculate the Gram filter exactly and improve the performance of backprojection. In the special case of parallel X‐ray beam geometry, the forward and backprojection can be implemented by an estimated Gram filter efficiently if the sinogram signal is bandlimited. In this paper, a specialized sinogram interpolation method is proposed to eliminate the bandlimited prerequisite and thus improve the reconstruction accuracy. We build on this idea by utilizing the continuity of the voxel‐basis' footprint, which provides a more accurate sinogram interpolation and further improves the efficiency and quality of backprojection. In addition, the detector blur effect can be efficiently accounted for in our method to better handle realistic scenarios. ResultsThe proposed method is tested on both phantom and real computed tomography (CT) images under different resolutions, sinogram sampling steps, and noise levels. The proposed method consistently outperforms other state‐of‐the‐art projection models in terms of speed and accuracy for both backprojection and reconstruction. ConclusionsWe proposed a iterative reconstruction methodology for 3D parallel‐beam X‐ray CT reconstruction. Our experimental results demonstrate that the proposed methodology is accurate, fast, and reproducible, and outperforms alternative state‐of‐the‐art projection models on both backprojection and reconstruction results significantly.more » « less
An official website of the United States government
