skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Search for: All records

Award ID contains: 2014506

Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher. Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?

Some links on this page may take you to non-federal websites. Their policies may differ from this site.

  1. Abstract Human biomechanical data are often accompanied with measurement noise and behavioral variability. Errors due to such noise and variability are usually exaggerated by fewer trials or shorter trial durations and could be reduced using more trials or longer trial durations. Speeding up such data collection by lowering number of trials or trial duration, while improving the accuracy of statistical estimates, would be of particular interest in wearable robotics applications and when the human population studied is vulnerable (e.g., the elderly). Here, we propose the use of the James–Stein estimator (JSE) to improve statistical estimates with a given amount of data or reduce the amount of data needed for a given accuracy. The JSE is a shrinkage estimator that produces a uniform reduction in the summed squared errors when compared with the more familiar maximum likelihood estimator (MLE), simple averages, or other least squares regressions. When data from multiple human participants are available, an individual participant’s JSE can improve upon MLE by incorporating information from all participants, improving overall estimation accuracy on average. Here, we apply the JSE to multiple time series of kinematic and metabolic data from the following parameter estimation problems: foot placement control during level walking, energy expenditure during circle walking, and energy expenditure during resting. We show that the resulting estimates improve accuracy—that is, the James–Stein estimates have lower summed squared error from the ‘true’ value compared with more conventional estimates. 
    more » « less
  2. Human walking contains variability due to small intrinsic perturbations arising from sensory or motor noise, or to promote motor learning. We hypothesize that such stride-to-stride variability may increase the metabolic cost of walking over and above a perfectly periodic motion, and that neglecting such variability in simulations may mis-estimate the metabolic cost. Here, we quantify the metabolic estimation errors accrued by neglecting the stride-to-stride variability using human data and a musculoskeletal model by comparing the cost of multiple strides of walking and the cost of a perfectly periodic stride with averaged kinematics and kinetics. We find that using an averaged stride underestimates the cost by approximately 2.5%, whereas using a random stride may mis-estimate the cost positively or negatively by up to 15%, ignoring the contribution of measurement errors to the observed stride-to-stride variability. As a further illustration of the cost increase in a simpler dynamical context, we use a feedback-controlled inverted pendulum walking model to show that increasing the sensory or motor noise increases the overall metabolic cost, as well as the variability of stride-to-stride metabolic costs, as seen with the musculoskeletal simulations. Our work establishes the importance of accounting for stride-to-stride variability when estimating metabolic costs from motion. 
    more » « less
    Free, publicly-accessible full text available November 1, 2026
  3. Humans typically walk at low speeds and run at higher speeds. Previous studies of transitions between walking and running were mostly on treadmills, but real-world locomotion allows more flexibility. Here, we study overground locomotion over long distances (800 or 2400 m) under time constraints, simulating everyday scenarios like traveling to an appointment. Unlike on treadmills, participants can vary both speed and gait during this task. Gait transition in this overground task occurs over a broad ‘gait transition regime’ spanning average speeds from 1.9 to 3.0 m s−1. In this regime, people use mixtures of walking and running on each travel bout: mostly walking at low average speeds (around 1.9 m s−1) and mostly running at high average speeds (3.0 m s−1). The walk–run fraction changes gradually between these speed limits and is 50% at about 2.5 m s−1. Within each walk–run mixture, walking is slower than running, with an unused gap between the two gait speeds. These gait mixtures and their speed dependence are predicted by energy optimality. These findings extend earlier results for shorter distances, showing that similar energetic principles govern longer, more physically and cognitively demanding tasks. Our results highlight the role of whole-task energy minimization including transients in shaping human locomotion and gait choice. 
    more » « less
    Free, publicly-accessible full text available November 1, 2026
  4. Shahzad, Faisal (Ed.)
    Most research aimed at measuring biomarkers on the skin is only concerned with sensing chemicals in sweat using electrical signals, but these methods are not truly non-invasive nor non-intrusive because they require substantial amounts of sweat to get a reading. This project aims to create a truly non-invasive wearable sensor that continuously detects the gaseous acetone (a biomarker related to metabolic disorders) that ambiently comes out of the skin. Composite films of polyaniline and cellulose acetate, exhibiting chemo-mechanical actuation upon exposure to gaseous acetone, were tested in the headspaces above multiple solutions containing acetone, ethanol, and water to gauge response sensitivity, selectivity, and repeatability. The bending of the films in response to exposures to these environments was tracked by an automatic video processing code, which was found to out-perform an off-the-shelf deep neural network-based tracker. Using principal component analysis, we showed that the film bending is low dimensional with over 90% of the shape changes being captured with just two parameters. We constructed forward models to predict shape changes from the known exposure history and found that a linear model can explain 40% of the observed variance in film tip angle changes. We constructed inverse models, going from third order fits of shape changes to acetone concentrations where about 45% of the acetone variation and about 30% of ethanol variation are captured by linear models, and non-linear models did not perform substantially better. This suggests there is sufficient sensitivity and inherent selectivity of the films. These models, however, provide evidence for substantial hysteretic or long-time-scale responses of the PANI films, seemingly due to the presence of water. Further experiments will allow more accurate discrimination of unknown exposure environments. Nevertheless, the sensor will operate with high selectivity in low sweat body locations, like behind the ear or on the nails. 
    more » « less
  5. Polyaniline is a conducting polymer in which both redox and protonating/ deprotonating conduction mechanisms are activated in the presence of gaseous compounds, making it a gas sensor. Resistive chemosensors based on PANI, in particular, have been well studied for their gas sensing properties and are considered important sensing materials for a wide range of applications as they operate at room temperature. There is, however, a novel class of polyaniline hybrids with cellulose acetate that may be suitable for detecting biomarkers emitted from the skin and in measuring the pH of breath condensate for diseases and thus, worth studying them further. 
    more » « less
  6. This paper presents sensor nanotechnologies that can be used for the skin-based gas “smelling” of disease. Skin testing may provide rapid and reliable results, using specific “fingerprints” or unique patterns for a variety of diseases and conditions. These can include metabolic diseases, such as diabetes and cholesterol-induced heart disease; neurological diseases, such as Alzheimer’s and Parkinson’s; quality of life conditions, such as obesity and sleep apnea; pulmonary diseases, such as cystic fibrosis, asthma, and chronic obstructive pulmonary disease; gastrointestinal tract diseases, such as irritable bowel syndrome and colitis; cancers, such as breast, lung, pancreatic, and colon cancers; infectious diseases, such as the flu and COVID-19; as well as diseases commonly found in ICU patients, such as urinary tract infections, pneumonia, and infections of the blood stream. Focusing on the most common gaseous biomarkers in breath and skin, which is nitric oxide and carbon monoxide, and certain abundant volatile organic compounds (acetone, isoprene, ammonia, alcohols, sulfides), it is argued here that effective discrimination between the diseases mentioned above is possible, by capturing the relative sensor output signals from the detection of each of these biomarkers and identifying the distinct breath print for each disease. 
    more » « less