- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources2
- Resource Type
-
0000000002000000
- More
- Availability
-
20
- Author / Contributor
- Filter by Author / Creator
-
-
Exline MC, Stanacevic M (1)
-
Gouma, Pelagia-Irene (1)
-
O. Abe, Owen (1)
-
Qiu, Zanlin (1)
-
R. Jinschek, Joerg (1)
-
#Tyler Phillips, Kenneth E. (0)
-
#Willis, Ciara (0)
-
& Abreu-Ramos, E. D. (0)
-
& Abramson, C. I. (0)
-
& Abreu-Ramos, E. D. (0)
-
& Adams, S.G. (0)
-
& Ahmed, K. (0)
-
& Ahmed, Khadija. (0)
-
& Aina, D.K. Jr. (0)
-
& Akcil-Okan, O. (0)
-
& Akuom, D. (0)
-
& Aleven, V. (0)
-
& Andrews-Larson, C. (0)
-
& Archibald, J. (0)
-
& Arnett, N. (0)
-
- Filter by Editor
-
-
null (1)
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
COVID-19 may present with a variety of clinical syndromes, however, the upper airway and the lower respiratory tract are the principle sites of infection. Previous work on respiratory viral infections demonstrated that airway inflammation results in the release of volatile organic compounds as well as nitric oxide. The detection of these gases from patients’ exhaled breath offers a novel potential diagnostic target for COVID-19 that would offer realtime screening of patients for COVID-19 infection.youmore » « less
-
O. Abe, Owen; Qiu, Zanlin; R. Jinschek, Joerg; Gouma, Pelagia-Irene (, Sensors)null (Ed.)The hexagonal WO3 polymorph, h-WO3, has attracted attention due to its interatomic channels, allowing for a greater degree of intercalation compared to other WO3 polymorphs. Our research group has previously demonstrated h-WO3 to be a highly sensitive gas sensing material for a flu biomarker, isoprene. In this work, the gas sensing performance of this polymorph has been further investigated in two distinct configurations of the material produced by different processing routes. The first sample was synthesized using Na2WO4·2H2O and showed (100) faceting. The second sample was synthesized using WCl6 and showed (001) faceting. The gas sensing response of the nanostructured films deposited using the (100) textured h-WO3 sample 1 had a higher response to acetone at 350 °C. The (001) textured h-WO3 sample 2 favored isoprene at 350 °C. The selectivity of the latter to isoprene is explained in terms of the dangling bonds present on the (001) facets. The tungsten and oxygen dangling bonds present on the (001) plane favor the adsorption of the isoprene molecule over that of the acetone molecule due to the oxygen containing dipole present in the acetone molecule.more » « less
An official website of the United States government

Full Text Available