A<sc>bstract</sc> Neutrino detectors are among the largest photon detection instruments, built to capture scarce photons upon energy deposition. Many discoveries in neutrino physics, including the neutrino itself, are inseparable from the advances in photon detection technology, particularly in photo-sensors and readout electronics, to yield ever higher precision and richer detection information. The measurement of the energy of neutrinos, referred to ascalorimetry, can be achieved in two distinct approaches: photon-counting, where single-photon can be counted digitally, and photon-integration, where multi-photons are aggregated and estimated via analogue signals. The energy is pursued today to reach permille level systematics control precision in ever-vast volumes, exemplified by experiments like JUNO. The unprecedented precision brings to the foreground the systematics due to calorimetric response entanglements in energy, position and time that were negligible in the past, thus driving further innovation in calorimetry. This publication describes a novel articulation that detectors can be endowed with multiple photon detection systems. Thismulti-calorimetryapproach opens the notion ofdual-calorimetrydetector, consisting of both photon-counting and photon-integration systems, as a cost-effective evolution from thesingle-calorimetrysetups used over several decades for most experiments so far. The dual-calorimetry design exploits unique response synergies between photon-counting and photon-integration systems, including correlations and cancellations in calorimetric responses, to maximise the mitigation of response entanglements, thereby yielding permille-level high-precision calorimetry.more » « lessFree, publicly-accessible full text available December 3, 2025
-
Abstract The Jiangmen Underground Neutrino Observatory (JUNO) is a large-scale neutrino experiment with multiple physics goals including determining the neutrino mass hierarchy, the accurate measurement of neutrino oscillation parameters, the neutrino detection from supernovae, the Sun, and the Earth, etc. JUNO puts forward physically and technologically stringent requirements for its central detector (CD), including a large volume and target mass (20 kt liquid scintillator, LS), a high-energy resolution (3% at 1 MeV), a high light transmittance, the largest possible photomultiplier (PMT) coverage, the lowest possible radioactive background, etc. The CD design, using a spherical acrylic vessel with a diameter of 35.4 m to contain the LS and a stainless steel structure to support the acrylic vessel and PMTs, was chosen and optimized. The acrylic vessel and the stainless steel structure will be immersed in pure water to shield the radioactive background and bear great buoyancy. The challenging requirements of the acrylic sphere have been achieved, such as a low intrinsic radioactivity and high transmittance of the manufactured acrylic panels, the tensile and compressive acrylic node design with embedded stainless steel pad, and one-time polymerization for multiple bonding lines. Moreover, several technical challenges of the stainless steel structure have been solved: the production of low radioactivity stainless steel material, the deformation and precision control during production and assembly, and the usage of high-strength stainless steel rivet bolt and of high friction efficient linkage plate. Finally, the design of the ancillary equipment such as the LS filling, overflowing, and circulating system was done.more » « lessFree, publicly-accessible full text available December 26, 2025
-
Abstract We explore the decay of bound neutrons in the JUNO liquid scintillator detector into invisible particles (e.g.,$$n\rightarrow 3 \nu $$ or$$nn \rightarrow 2 \nu $$ ), which do not produce an observable signal. The invisible decay includes two decay modes:$$ n \rightarrow { inv} $$ and$$ nn \rightarrow { inv} $$ . The invisible decays ofs-shell neutrons in$$^{12}\textrm{C}$$ will leave a highly excited residual nucleus. Subsequently, some de-excitation modes of the excited residual nuclei can produce a time- and space-correlated triple coincidence signal in the JUNO detector. Based on a full Monte Carlo simulation informed with the latest available data, we estimate all backgrounds, including inverse beta decay events of the reactor antineutrino$${\bar{\nu }}_e$$ , natural radioactivity, cosmogenic isotopes and neutral current interactions of atmospheric neutrinos. Pulse shape discrimination and multivariate analysis techniques are employed to further suppress backgrounds. With two years of exposure, JUNO is expected to give an order of magnitude improvement compared to the current best limits. After 10 years of data taking, the JUNO expected sensitivities at a 90% confidence level are$$\tau /B( n \rightarrow { inv} ) > 5.0 \times 10^{31} \, \textrm{years}$$ and$$\tau /B( nn \rightarrow { inv} ) > 1.4 \times 10^{32} \, \textrm{years}$$ .more » « lessFree, publicly-accessible full text available January 1, 2026
-
Abstract The Jiangmen Underground Neutrino Observatory (JUNO) is a multi-purpose neutrino experiment under construction in South China. This paper presents an updated estimate of JUNO’s sensitivity to neutrino mass ordering using the reactor antineutrinos emitted from eight nuclear reactor cores in the Taishan and Yangjiang nuclear power plants. This measurement is planned by studying the fine interference pattern caused by quasi-vacuum oscillations in the oscillated antineutrino spectrum at a baseline of 52.5 km and is completely independent of the CP violating phase and neutrino mixing angleθ23. The sensitivity is obtained through a joint analysis of JUNO and Taishan Antineutrino Observatory (TAO) detectors utilizing the best available knowledge to date about the location and overburden of the JUNO experimental site, local and global nuclear reactors, JUNO and TAO detector responses, expected event rates and spectra of signals and backgrounds, and systematic uncertainties of analysis inputs. We find that a 3σmedian sensitivity to reject the wrong mass ordering hypothesis can be reached with an exposure of about 6.5 years × 26.6 GW thermal power.more » « lessFree, publicly-accessible full text available March 1, 2026
-
Abstract This paper presents an energy resolution study of the JUNO experiment, incorporating the latest knowledge acquired during the detector construction phase. The determination of neutrino mass ordering in JUNO requires an exceptional energy resolution better than 3% at 1 MeV. To achieve this ambitious goal, significant efforts have been undertaken in the design and production of the key components of the JUNO detector. Various factors affecting the detection of inverse beta decay signals have an impact on the energy resolution, extending beyond the statistical fluctuations of the detected number of photons, such as the properties of the liquid scintillator, performance of photomultiplier tubes, and the energy reconstruction algorithm. To account for these effects, a full JUNO simulation and reconstruction approach is employed. This enables the modeling of all relevant effects and the evaluation of associated inputs to accurately estimate the energy resolution. The results of this study reveal an energy resolution of 2.95% at 1 MeV. Furthermore, this study assesses the contribution of major effects to the overall energy resolution budget. This analysis serves as a reference for interpreting future measurements of energy resolution during JUNO data collection. Moreover, it provides a guideline for comprehending the energy resolution characteristics of liquid scintillator-based detectors.more » « less