Title: Rapid 1024-pixel Electrochemical Imaging at 10,000 Frames per Second using Monolithic CMOS Sensor and Multifunctional Data Acquisition System
Fast electrochemical imaging enables the dynamic study of electroactive molecule diffusion in neurotransmitter release from single cells and dopamine mapping in brain slices. In this paper, we discuss the design of an electrochemical imaging sensor using a monolithic CMOS sensor array and a multifunctional data acquisition system. Using post-CMOS fabrication, the CMOS sensor integrates 1024 on-chip electrodes on the surface and contains 1024 low-noise amplifiers to simultaneous process parallel electrochemical recordings. Each electrochemical electrode and amplifier are optimized to operate at 10.38 kHz sampling rate. To support the operation of the high-throughput CMOS device, a multifunctional data acquisition device is developed to provide the required speed and accuracy. The high analog data rate of 10.63 MHz from all 1024 amplifiers is redundantly sampled by the custom-designed data acquisition system which can process up to 73.6 MHz with up to ~400 Mbytes/s data rate to a computer using USB 3.0 interface. To contain the liquid above the electrochemical sensors and prevent electronic and wire damage, we packaged the monolithic sensor using a 3D-printed well. Using the presented device, 32 pixel × 32 pixel electrochemical imaging of dopamine diffusion is successfully demonstrated at over 10,000 frames per second, the fastest reported to date.  more » « less
Award ID(s):
1745364
NSF-PAR ID:
10059823
Author(s) / Creator(s):
; ;
Date Published:
Journal Name:
IEEE Sensors Journal
ISSN:
1530-437X
Page Range / eLocation ID:
1 to 1
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Neuroblastoma cells are often used as a cell model to study Parkinson's disease, which causes reduced dopamine release in substantia nigra, the midbrain that controls movements. In this paper, we developed a 1024-ch monolithic CMOS sensor array that has the spatiotemporal resolution as well as low-noise performance to monitor single vesicle release of dopamine from neuroblastoma cells. The CMOS device integrates 1024 on-chip electrodes with an individual size of 15 μm × 15 μm and 1024 transimpedance amplifiers for each electrode, which are each capable of measuring sub-pA current. Thus, this device can be used to study the detailed molecular dynamics of dopamine secretion at single vesicle resolution. 
    more » « less
  2. Graphene nanocomposites are a promising class of advanced materials for sensing applications; yet, their commercialization is hindered due to impurity incorporation during fabrication and high costs. The aim of this work is to prepare graphene–polysulfone (G−PSU) and graphene–polyvinylidene fluoride (G−PVDF) nanocomposites that perform as multifunctional sensors and are formed using a one-step, in situ exfoliation process whereby graphite is exfoliated into graphene nanoflakes (GNFs) directly within the polymer. This low-cost method creates a nanocomposite while avoiding impurity exposure since the raw materials used in the in situ shear exfoliation process are graphite and polymers. The morphology, structure, thermal properties, and flexural properties were determined for G−PSU and G−PVDF nanocomposites, as well as the electromechanical sensor capability during cyclic flexural loading, temperature sensor testing while heating and cooling, and electrochemical sensor capability to detect dopamine while sensing data wirelessly. G−PSU and G−PVDF nanocomposites show superior mechanical characteristics (gauge factor around 27 and significantly enhanced modulus), thermal characteristics (stability up to 500 °C and 170 °C for G−PSU and G−PVDF, respectively), electrical characteristics (0.1 S/m and 1 S/m conductivity for G−PSU and G−PVDF, respectively), and distinguished resonant peaks for wireless sensing (~212 MHz and ~429 MHz). These uniquely formed G−PMC nanocomposites are promising candidates as strain sensors for structural health monitoring, as temperature sensors for use in automobiles and aerospace applications, and as electrochemical sensors for health care and disease diagnostics.

     
    more » « less
  3. A common problem in single-cell measurement is the low-throughput nature of measurements. Monolithic CMOS microsystems have enabled many parallel measurements to take place simultaneously to increase throughput due to the integration of electrodes and amplifiers into a single chip. This paper explores a CMOS chip containing an array of 1024 parallel transimpedance amplifiers that takes advantage of a “half-shared” operational amplifier architecture. This architecture splits a traditional 5-transistor operational amplifier into two, the inverting half and the non-inverting half. Splitting an amplifier into two allows for the non-inverting half to be “shared” with several inverting halves, reducing the die area required for each individual amplifier. This allows for an increased number of amplifiers to be embedded into the same chip; in this case, 32 amplifiers are able to fit in the same space as 17 traditional 5-transistor operational amplifiers. The amplifiers exhibit low mismatch of 1.65 mV across the entire 1024 amplifier array, as well as high linearity in transimpedance gain. The technique will enable larger arrays to be created in future designs to allow electrophysiologists, among others, access to even higher-throughput measurement tools. 
    more » « less
  4. An eight-element oil-filled hydrophone array is used to measure the acoustic field in littoral waters. This prototype array was deployed during an experiment between Jeffrey’s Ledge and the Stellwagen Bank region off the coast of Rockport, Massachusetts USA. During the experiment, several humpback whale vocalizations, distant ship tonals and high frequency conventional echosounder pings were recorded. Visual confirmation of humpback moving in bearing relative to the array verifies the directional sensing from array beamforming. During deployment, the array is towed at speeds varying from 4-7 kts in water depths of roughly 100 m with conditions at sea state 2 to 3. This array system consists of a portable winch with array, tow cable and 3 water-resistant boxes housing electronics. This system is deployed and operated by 2 crew members onboard a 13 m commercial fishing vessel during the experiment. Non-acoustic sensor (NAS) information is obtained to provide depth, temperature, and heading data using commercial off the shelf (COTS) components utilizing RS485/232 data communications. Acoustic data sampling was performed at 8 kHz, 30 kHz and 100 kHz with near real-time processing of data and enhanced Signal to Noise Ratio (SNR) from beamforming. The electrical system components are deployed with 3 stacked electronics boxes housing power, data acquisition and data processing components in water resistant compartments. A laptop computer with 8 TB of external storage and an independent Global Positioning System (GPS) antenna is used to run Passive Ocean Acoustic Waveguide Remote Sensing (POAWRS) software providing beamformed spectrogram data and live NAS data with capability of capturing several days of data. The acquisition system consists of Surface Mount Device (SMD) pre-amplifiers with filter to an analog differential pair shipboard COTS acquisition system. Pre-amplifiers are constructed using SMD technology where components are pressure tolerant and potting is not necessary. Potting of connectors, electronics and hydrophones via 3D printed molding techniques will be discussed. Array internal components are manufactured with Thermoplastic Polyurethane (TPU) 3D printed material to dampen array vibrations with forward and aft vibration isolation modules (VIM). Polyurethane foam (PUF) used to scatter breathing waves and dampen contact from wires inside the array without attenuating high frequencies and allowing for significant noise reduction. A single Tygon array section with a length of 7.5 m and diameter of 38 mm contains 8 transducer elements with a spacing of 75 cm (1 kHz design frequency). Pre- amplifiers and NAS modules are affixed using Vectran and steel wire rope positioned by swaged stops along the strength member. The tow cable length is 100 m with a diameter of 22 mm that is potted to a hose adapter to break out 12 braided copper wire twisted pair conductors and terminates the tow cable Vectran braid. This array in its current state of development is a low-cost alternative to obtain quality acoustic data from a towed array system. Used here for observation of whale vocalizations, this type of array also has many applications in military sonar and seismic surveying. Maintenance on the array can be performed without the use of special facilities or equipment for dehosing and conveniently uses castor oil as an environmentally safe pressure compensating and coupling fluid. Array development including selection of transducers, NAS modules, acoustic acquisition system, array materials and method of construction with results from several deployments will be discussed. We also present beamformed spectrograms containing humpback whale downsweep moans and underwater blowing (bubbles) sounds associated with feeding on sand lance (Ammodytes dubius). 
    more » « less
  5. While classical electrochemical impedance spectroscopy (EIS) focuses on measurements from a single working electrode, dense active microelectrode arrays offer opportunities for new modes of sensing. Here we present experimental results with an integrated sensor array for electrochemical imaging. The system uses a 100 x 100 custom CMOS electrode array with 10 micron pixels, which measures impedance at frequencies up to 100 MHz. The sensor chip is uniquely designed to take advantage of the electrostatic coupling between groups of nearby pixels to re-shape the local electric field. Multiple bias voltages and clock phases create new types of signal diversity that will enable enhanced sensing modes for computational imaging and impedance tomography. 
    more » « less