skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Title: Probing surfaces of atmospherically relevant organic particles by easy ambient sonic-spray ionization mass spectrometry (EASI-MS)
Both ambient and laboratory-generated particles can have a surface composition different from the bulk, but there are currently few analytical techniques available to probe these differences. Easy ambient sonic-spray ionization mass spectrometry (EASI-MS) was applied to solid, laboratory-generated particles with core–shell morphologies formed from a variety of dicarboxylic acids. The soft ionization facilitated parent peak detection for the two compounds, from which the depth probed could be determined from the relative signal intensities. Two different configurations of a custom-made nebulizer are reported that yield different probe depths. In the “orthogonal mode,” with the nebulizer ∼10 centimeters away from the particle stream and at a 90° angle to the MS inlet, evaporation of the nebulizer droplets forms ions before interaction with the particles. The probe depth for orthogonal mode EASI-MS is shown to be 2–4 nm in these particle systems. In the “droplet mode”, the nebulizer and particle streams are in close proximity to each other and the MS inlet so that the particles interact with charged liquid droplets. This configuration resulted in full dissolution of the particles and gives particle composition similar to that from collection on filters and extraction of the particles (bulk). These studies establish that EASI-MS is a promising technique for probing the chemical structures of inhomogeneous airborne organic particles.  more » « less
Award ID(s):
1647386
PAR ID:
10123478
Author(s) / Creator(s):
;
Date Published:
Journal Name:
Chemical Science
Volume:
10
Issue:
3
ISSN:
2041-6520
Page Range / eLocation ID:
884 to 897
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract Number: 381 Working Group: Instrumentation and Methods Abstract The phase state of atmospheric aerosol particles – solid, semi-solid, or liquid – influences their ability to take up water and participate in heterogeneous chemical reactions. Changes in phase state have been predicted by glass transition temperature (Tg) and viscosity; however, direct measurements of these properties is challenging for sub-micron particles. Historically, bulk measurements have been used, but this does not account for particle-to-particle variation or the impacts of particle size. Melting temperature (Tm) is the most significant predictor of Tg, and the two properties can be related through the Boyer-Beaman rule. Herein, we apply a recently developed method utilizing a nano-thermal analysis (nanoTA) module coupled to an atomic force microscope (AFM), to determine the Tm of individual secondary organic aerosol (SOA) particles generated from the reactive uptake of isoprene-derived epoxydiols (IEPOX) onto acidic ammonium sulfate aerosol particles. NanoTA works by using a specialized AFM probe which can be heated while in contact with a particle of interest. As the temperature increases, the probe deflection will first increase due to thermal expansion of the particle followed by a decrease at its Tm. The direct measurements are compared with model predictions based on molecular composition from hydrophilic interaction liquid chromatography coupled to electrospray ionization high-resolution quadrupole time-of-flight mass spectrometry (HILIC/ESI-HR-QTOF-MS) analysis. We compared the Tm of the SOA particles formed from IEPOX uptake onto acidic ammonium sulfate particles created at 30, 65, and 80% relative humidity (RH), and found that increasing RH from 30 to 80% led to an overall decrease in average Tm, indicating less viscous particles at higher RH conditions. Our measurements with this technique will allow for more accurate representations of the phase state of aerosols in the atmosphere. 
    more » « less
  2. The phase state of atmospheric aerosol particles – solid, semi-solid, or liquid – influences their ability to take up water and participate in heterogeneous chemical reactions. Changes in phase state have been predicted by glass transition temperature (Tg) and viscosity; however, direct measurements of these properties is challenging for sub-micron particles. Historically, bulk measurements have been used, but this does not account for particle-to-particle variation or the impacts of particle size. Melting temperature (Tm) is the most significant predictor of Tg, and the two properties can be related through the Boyer-Beaman rule. Herein, we apply a recently developed method utilizing a nano-thermal analysis (nanoTA) module coupled to an atomic force microscope (AFM), to determine the Tm of individual secondary organic aerosol (SOA) particles generated from the reactive uptake of isoprene-derived epoxydiols (IEPOX) onto acidic ammonium sulfate aerosol particles. NanoTA works by using a specialized AFM probe which can be heated while in contact with a particle of interest. As the temperature increases, the probe deflection will first increase due to thermal expansion of the particle followed by a decrease at its Tm. The direct measurements are compared with model predictions based on molecular composition from hydrophilic interaction liquid chromatography coupled to electrospray ionization high-resolution quadrupole time-of-flight mass spectrometry (HILIC/ESI-HR-QTOF-MS) analysis. We compared the Tm of the SOA particles formed from IEPOX uptake onto acidic ammonium sulfate particles created at 30, 65, and 80% relative humidity (RH), and found that increasing RH from 30 to 80% led to an overall decrease in average Tm, indicating less viscous particles at higher RH conditions. Our measurements with this technique will allow for more accurate representations of the phase state of aerosols in the atmosphere. 
    more » « less
  3. RationaleIn droplet‐assisted ionization (DAI), intact molecular ions are generated from molecules in aerosol droplets by passing the droplets through a temperature‐controlled capillary inlet. Ion formation is explored through the effects of analyte mass flow, droplet solvent composition, and capillary temperature on ion signal intensity. MethodsA Waters SYNAPT G2‐S is adapted for DAI by reconfiguring the inlet with a temperature‐controlled capillary. Droplets are generated by atomization of a solution containing analyte and then sampled through the inlet. If desired, solvent can be removed from the droplets prior to analysis by sending the aerosol through a series of diffusion dryers. Size distributions of the dried aerosols allow the mass flow of analyte into the inlet to be determined. ResultsAnalyte signal intensities are orders of magnitude higher from droplets containing a protic solvent (water) than an aprotic solvent (acetonitrile). The highest signal intensities for DAI are obtained with inlet temperatures above 500°C, though the optimum temperature is analyte dependent. At elevated temperatures, droplets are thought to undergo rapid solvent evaporation and bursting to produce ions. The lowest signal intensities are generally obtained in the 100–350°C range, where slow solvent evaporation is thought to inhibit ion formation. As the temperature decreases from 100°C down to 25°C, the signal intensity increases significantly. When 3‐nitrobenzonitrile, a common matrix for solid‐state matrix‐assisted ionization (MAI), is added to droplets consisting of 50/50 v/v water and acetonitrile, the matrix enhances ion formation to produce a signal intensity comparable to DAI in 100% water. ConclusionsThe results are consistent with other inlet ionization techniques, suggesting that similar ion formation mechanisms are operative. Optimized ion yields (the combined effects of ionization probability and ion transmission) for DAI are currently in the 10−5to 10−6range, which is sufficient for many aerosol applications. 
    more » « less
  4. Abstract. Extractive electrospray ionization (EESI) has been a well-knowntechnique for high-throughput online molecular characterization of chemicalreaction products and intermediates, detection of native biomolecules, invivo metabolomics, and environmental monitoring with negligible thermal andionization-induced fragmentation for over two decades. However, the EESIextraction mechanism remains uncertain. Prior studies disagree on whetherparticles between 20 and 400 nm diameter are fully extracted or if theextraction is limited to the surface layer. Here, we examined the analyteextraction mechanism by assessing the influence of particle size and coatingthickness on the detection of the molecules therein. We find that particlesare extracted fully: organics-coated NH4NO3 particles with afixed core volume (156 and 226 nm in diameter without coating) showedconstant EESI signals for NH4NO3 independent of the shell coatingthickness, while the signals of the secondary organic molecules comprisingthe shell varied proportionally to the shell volume. We also found that theEESI sensitivity exhibited a strong size dependence, with an increase insensitivity by 1–3 orders of magnitude as particle size decreasedfrom 300 to 30 nm. This dependence varied with the electrospray (ES)droplet size, the particle size and the residence time for coagulation in theEESI inlet, suggesting that the EESI sensitivity was influenced by thecoagulation coefficient between particles and ES droplets. Overall, ourresults indicate that, in the EESI, particles are fully extracted by the ESdroplets regardless of the chemical composition, when they are collected bythe ES droplets. However, their coalescence is not complete and dependsstrongly on their size. This size dependence is especially relevant whenEESI is used to probe size-varying particles as is the case in aerosolformation and growth studies with size ranges below 100 nm. 
    more » « less
  5. The application of direct analysis in real-time mass spectrometry (DART-MS), which is finding increasing use in atmospheric chemistry, to two different laboratory model systems for airborne particles is investigated: (1) submicron C3–C7 dicarboxylic acid (diacid) particles reacted with gas-phase trimethylamine (TMA) or butylamine (BA) and (2) secondary organic aerosol (SOA) particles from the ozonolysis of α-cedrene. The diacid particles exhibit a clear odd–even pattern in their chemical reactivity toward TMA and BA, with the odd-carbon diacid particles being substantially more reactive than even ones. The ratio of base to diacid in reacted particles, determined using known diacid–base mixtures, was compared to that measured by high-resolution time-of-flight aerosol mass spectrometry (HR-ToF-AMS), which vaporizes the whole particle. Results show that DART-MS probes  ∼  30 nm of the surface layer, consistent with other studies on different systems. For α-cedrene SOA particles, it is shown that varying the temperature of the particle stream as it enters the DART-MS ionization region can distinguish between specific components with the same molecular mass but different vapor pressures. These results demonstrate the utility of DART-MS for (1) examining reactivity of heterogeneous model systems for atmospheric particles and (2) probing components of SOA particles based on volatility. 
    more » « less