Title: Three-dimensional phase optical transfer function in axially symmetric microscopic quantitative phase imaging
Three-dimensional quantitative phase imaging (3D QPI) is widely recognized as a potentially high-impact microscopic modality. Central to determining the resolution capability of 3D QPI is the phase optical transfer function (POTF). The magnitude of the POTF over its spatial frequency coverage (SFC) specifies the intensity of the response for each allowed spatial frequency. In this paper, a detailed analysis of the POTF for an axially symmetric optical configuration is presented. First, a useful geometric interpretation of the SFC, which enables its visualization, is presented. Second, a closed-form 1D integral expression is derived for the POTF in the general nonparaxial case, which enables rapid calculation of the POTF. Third, this formulation is applied to disk, annular, multi-annuli, and Gaussian illuminations as well as to an annular objective. Taken together, these contributions enable the visualization and simplified calculation of the 3D axially symmetric POTF and provide a basis for optimizing QPI in a wide range of applications.  more » « less
Award ID(s):
1915971
PAR ID:
10200207
Author(s) / Creator(s):
; ;
Publisher / Repository:
Optical Society of America
Date Published:
Journal Name:
Journal of the Optical Society of America A
Volume:
37
Issue:
12
ISSN:
1084-7529; JOAOD6
Format(s):
Medium: X Size: Article No. 1857
Size(s):
Article No. 1857
Sponsoring Org:
National Science Foundation
More Like this
  1. Quantitative phase imaging (QPI) is an invaluable microscopic technology for definitively imaging phase objects such as biological cells and optical fibers. Traditionally, the condenser lens in QPI produces disk illumination of the object. However, it has been realized by numerous investigators that annular illumination can produce higher-resolution images. Although this performance improvement is impressive and well documented, the evidence presented has invariably been qualitative in nature. Recently, a theoretical basis for annular illumination was presented by Baoet al.[Appl. Opt.58,137(2019)APOPAI0003-693510.1364/AO.58.000137]. In our current work, systematic experimental QPI measurements are made with a reference phase mask to rigorously document the performance of annular illumination. In both theory and experiment, three spatial-frequency regions are identified: low, mid, and high. The low spatial-frequency region response is very similar for disk and annular illumination, both theoretically and experimentally. Theoretically, the high spatial-frequency region response is predicted to be much better for the annular illumination compared to the disk illumination––and is experimentally confirmed. In addition, the mid-spatial-frequency region response is theoretically predicted to be less for annular illumination than for disk illumination. This theoretical degradation of the mid-spatial-frequency region is only slightly experimentally observed. This bonus, although not well understood, further elevates the performance of annular illumination over disk illumination. 
    more » « less
  2. The imaging performance of tomographic deconvolution phase microscopy can be described in terms of the phase optical transfer function (POTF) which, in turn, depends on the illumination profile. To facilitate the optimization of the illumination profile, an analytical calculation method based on polynomial fitting is developed to describe the POTF for general nonuniform axially symmetric illumination. This is then applied to Gaussian and related profiles. Compared to numerical integration methods that integrate over a series of annuli, the present analytical method is much faster and is equally accurate. Further, a “balanced distribution” criterion for the POTF and a least-squares minimization are presented to optimize the uniformity of the POTF. An optimum general profile is found analytically by relaxed optimal search, and an optimum Gaussian profile is found through a tree search. Numerical simulations confirm the performance of these optimum profiles and support the balanced distribution criterion introduced. 
    more » « less
  3. Abstract Quantitative phase imaging (QPI) recovers the exact wavefront of light from intensity measurements. Topographical and optical density maps of translucent microscopic bodies can be extracted from these quantified phase shifts. We demonstrate quantitative phase imaging at the tip of a coherent fiber bundle using chromatic aberrations inherent in a silicon nitride hyperboloid metalens. Our method leverages spectral multiplexing to recover phase from multiple defocus planes in a single capture using a color camera. Our 0.5 mm aperture metalens shows robust quantitative phase imaging capability with a$${28}^{\circ}$$ 28 field of view and 0.$${2}{\pi}$$ 2 π phase resolution ( ~ 0.$${1}{\lambda}$$ 1 λ in air) for experiments with an endoscopic fiber bundle. Since the spectral functionality is encoded directly in the imaging lens, the metalens acts both as a focusing element and a spectral filter. The use of a simple computational backend will enable real-time operation. Key limitations in the adoption of phase imaging methods for endoscopy such as multiple acquisition, interferometric alignment or mechanical scanning are completely mitigated in the reported metalens based QPI. 
    more » « less
  4. Abstract 3D organoid models have recently seen a boom in popularity, as they can better recapitulate the complexity of multicellular organs compared to other in vitro culture systems. However, organoids are difficult to image because of the limited penetration depth of high‐resolution microscopes and depth‐dependent light attenuation, which can limit the understanding of signal transduction pathways and characterization of intimate cell‐extracellular matrix (ECM) interactions. To overcome these challenges, phototransfer by allyl sulfide exchange‐expansion microscopy (PhASE‐ExM) is developed, enabling optical clearance and super‐resolution imaging of organoids and their ECM in 3D. PhASE‐ExM uses hydrogels prepared via photoinitiated polymerization, which is advantageous as it decouples monomer diffusion into thick organoid cultures from the hydrogel fabrication. Apart from compatibility with organoids cultured in Matrigel, PhASE‐ExM enables 3.25× expansion and super‐resolution imaging of organoids cultured in synthetic poly(ethylene glycol) (PEG) hydrogels crosslinked via allyl‐sulfide groups (PEG‐AlS) through simultaneous photopolymerization and radical‐mediated chain‐transfer reactions that complete in <70 s. Further, PEG‐AlS hydrogels can be in situ softened to promote organoid crypt formation, providing a super‐resolution imaging platform both for pre‐ and post‐differentiated organoids. Overall, PhASE‐ExM is a useful tool to decipher organoid behavior by enabling sub‐micrometer scale, 3D visualization of proteins and signal transduction pathways. 
    more » « less
  5. Abstract Due to its specificity, fluorescence microscopy has become a quintessential imaging tool in cell biology. However, photobleaching, phototoxicity, and related artifacts continue to limit fluorescence microscopy’s utility. Recently, it has been shown that artificial intelligence (AI) can transform one form of contrast into another. We present phase imaging with computational specificity (PICS), a combination of quantitative phase imaging and AI, which provides information about unlabeled live cells with high specificity. Our imaging system allows for automatic training, while inference is built into the acquisition software and runs in real-time. Applying the computed fluorescence maps back to the quantitative phase imaging (QPI) data, we measured the growth of both nuclei and cytoplasm independently, over many days, without loss of viability. Using a QPI method that suppresses multiple scattering, we measured the dry mass content of individual cell nuclei within spheroids. In its current implementation, PICS offers a versatile quantitative technique for continuous simultaneous monitoring of individual cellular components in biological applications where long-term label-free imaging is desirable. 
    more » « less