2D monochromatic x-ray imaging for beam monitoring of an x-ray free electron laser and a high-power femtosecond laser
- PAR ID:
- 10210844
- Publisher / Repository:
- American Institute of Physics
- Date Published:
- Journal Name:
- Review of Scientific Instruments
- Volume:
- 92
- Issue:
- 1
- ISSN:
- 0034-6748
- Page Range / eLocation ID:
- Article No. 013510
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
Bremsstrahlung x rays generated in laser-solid interactions can be used as light sources for high-energy-density science. We present electron and x-ray spectra from multidimensional kinetic simulations with varying laser pulse intensity and duration at fixed energy of 200J. A phenomenological model for the transition from superponderomotive to ponderomotive temperatures is described, yielding a temperature scaling that depends on pulse duration and density scale length. The shortest pulses create low-divergence electron beams before self-generated magnetic fields evolve, yielding 1–5−MeV forward-going x rays containing ∼0.5% of the laser energy.more » « less
-
Image formation by Fresnel diffraction utilizes both absorption and phase-contrast to measure electron density profiles. The low spatial and spectral coherence requirements allow the technique to be performed with a laser-produced x-ray source coupled with a narrow slit. This makes it an excellent candidate for probing interfaces between materials at extreme conditions, which can only be generated at large-scale laser or pulsed power facilities. Here, we present the results from a proof-of-principle experiment demonstrating an effective ∼2 μm laser-generated source at the OMEGA Laser Facility. This was achieved using slits of 1 × 30 μm2 and 2 × 40 μm2 geometry, which were milled into 30 μm thick Ta plates. Combining these slits with a vanadium He-like 5.2 keV source created a 1D imaging system capable of micrometer-scale resolution. The principal obstacles to achieving an effective 1 μm source are the slit tilt and taper—where the use of a tapered slit is necessary to increase the alignment tolerance. We demonstrate an effective source size by imaging a 2 ± 0.2 μm radius tungsten wire.more » « less
-
Single particle imaging at x-ray free electron lasers (XFELs) has the potential to determine the structure and dynamics of single biomolecules at room temperature. Two major hurdles have prevented this potential from being reached, namely, the collection of sufficient high-quality diffraction patterns and robust computational purification to overcome structural heterogeneity. We report the breaking of both of these barriers using gold nanoparticle test samples, recording around 10 million diffraction patterns at the European XFEL and structurally and orientationally sorting the patterns to obtain better than 3-nm-resolution 3D reconstructions for each of four samples. With these new developments, integrating advancements in x-ray sources, fast-framing detectors, efficient sample delivery, and data analysis algorithms, we illuminate the path towards sub-nanometer biomolecular imaging. The methods developed here can also be extended to characterize ensembles that are inherently diverse to obtain their full structural landscape.more » « less
An official website of the United States government
