skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

Attention:

The NSF Public Access Repository (PAR) system and access will be unavailable from 10:00 PM ET on Thursday, February 12 until 1:00 AM ET on Friday, February 13 due to maintenance. We apologize for the inconvenience.


Title: Phase- shifted 3D Imaging of Rotating Milling/Drilling tools
Drilling and milling operations are material removal processes involved in everyday conventional productions, especially in the high-speed metal cutting industry. The monitoring of tool information (wear, dynamic behavior, deformation, etc.) is essential to guarantee the success of product fabrication. Many methods have been applied to monitor the cutting tools from the information of cutting force, spindle motor current, vibration, as well as sound acoustic emission. However, those methods are indirect and sensitive to environmental noises. Here, the in-process imaging technique that can capture the cutting tool information while cutting the metal was studied. As machinists judge whether a tool is worn-out by the naked eye, utilizing the vision system can directly present the performance of the machine tools. We proposed a phase shifted strobo-stereoscopic method (Figure 1) for three-dimensional (3D) imaging. The stroboscopic instrument is usually applied for the measurement of fast-moving objects. The operation principle is as follows: when synchronizing the frequency of the light source illumination and the motion of object, the object appears to be stationary. The motion frequency of the target is transferring from the count information of the encoder signals from the working rotary spindle. If small differences are added to the frequency, the object appears to be slowly moving or rotating. This effect can be working as the source for the phase-shifting; with this phase information, the target can be whole-view 3D reconstructed by 360 degrees. The stereoscopic technique is embedded with two CCD cameras capturing images that are located bilateral symmetrically in regard to the target. The 3D scene is reconstructed by the location information of the same object points from both the left and right images. In the proposed system, an air spindle was used to secure the motion accuracy and drilling/milling speed. As shown in Figure 2, two CCDs with 10X objective lenses were installed on a linear rail with rotary stages to capture the machine tool bit raw picture for further 3D reconstruction. The overall measurement process was summarized in the flow chart (Figure 3). As the count number of encoder signals is related to the rotary speed, the input speed (unit of RPM) was set as the reference signal to control the frequency (f0) of the illumination of the LED. When the frequency was matched with the reference signal, both CCDs started to gather the pictures. With the mismatched frequency (Δf) information, a sequence of images was gathered under the phase-shifted process for a whole-view 3D reconstruction. The study in this paper was based on a 3/8’’ drilling tool performance monitoring. This paper presents the principle of the phase-shifted strobe-stereoscopic 3D imaging process. A hardware set-up is introduced, , as well as the 3D imaging algorithm. The reconstructed image analysis under different working speeds is discussed, the reconstruction resolution included. The uncertainty of the imaging process and the built-up system are also analyzed. As the input signal is the working speed, no other information from other sources is required. This proposed method can be applied as an on-machine or even in-process metrology. With the direct method of the 3D imaging machine vision system, it can directly offer the machine tool surface and fatigue information. This presented method can supplement the blank for determining the performance status of the machine tools, which further guarantees the fabrication process.  more » « less
Award ID(s):
1902697
PAR ID:
10217890
Author(s) / Creator(s):
;
Date Published:
Journal Name:
American Society for Precision Engineering
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. This paper introduces a simple three-dimensional (3D) stereoscopic method using a single unit of an imaging device consisting of a charge-coupled device (CCD) and a zoom lens. Unlike conventional stereoscopy, which requires a pair of imaging devices, 3D surface imaging is achieved by 3D image reconstruction of two images obtained from two different camera positions by scanning. The experiments were performed by obtaining two images of the measurement target in two different ways: (1) by moving the object while the imaging device is stationary, and (2) by moving the imaging device while the object is stationary. Conventional stereoscopy is limited by disparity errors in 3D image reconstruction because a pair of imaging devices is not ideally identical and alignment errors are always present in the imaging system setup. The proposed method significantly reduced the disparity error in 3D image reconstruction, and the calibration process of the imaging system became simple and convenient. The proposed imaging system showed a disparity error of 0.26 in the camera pixel. 
    more » « less
  2. Mask-based integrated fluorescence microscopy is a compact imaging technique for biomedical research. It can perform snapshot 3D imaging through a thin optical mask with a scalable field of view (FOV). Integrated microscopy uses computational algorithms for object reconstruction, but efficient reconstruction algorithms for large-scale data have been lacking. Here, we developed DeepInMiniscope, a miniaturized integrated microscope featuring a custom-designed optical mask and an efficient physics-informed deep learning model that markedly reduces computational demand. Parts of the 3D object can be individually reconstructed and combined. Our deep learning algorithm can reconstruct object volumes over 4 millimeters by 6 millimeters by 0.6 millimeters. We demonstrated substantial improvement in both reconstruction quality and speed compared to traditional methods for large-scale data. Notably, we imaged neuronal activity with near-cellular resolution in awake mouse cortex, representing a substantial leap over existing integrated microscopes. DeepInMiniscope holds great promise for scalable, large-FOV, high-speed, 3D imaging applications with compact device footprint. 
    more » « less
  3. Abstract We present a feature-selective segmentation and merging technique to achieve spatially resolved surface profiles of the parts by 3D stereoscopy and strobo-stereoscopy. A pair of vision cameras capture images of the parts at different angles, and 3D stereoscopic images can be reconstructed. Conventional filtering processes of the 3D images involve data loss and lower the spatial resolution of the image. In this study, the 3D reconstructed image was spatially resolved by automatically recognizing and segmenting the features on the raw images, locally and adaptively applying super-resolution algorithm to the segmented images based on the classified features, and then merging those filtered segments. Here, the features are transformed into masks that selectively separate the features and background images for segmentation. The experimental results were compared with those of conventional filtering methods by using Gaussian filters and bandpass filters in terms of spatial frequency and profile accuracy. As a result, the selective feature segmentation technique was capable of spatially resolved 3D stereoscopic imaging while preserving imaging features. 
    more » « less
  4. Measuring speed is a critical factor to reduce motion artifacts for dynamic scene capture. Phase-shifting methods have the advantage of providing high-accuracy and dense 3D point clouds, but the phase unwrapping process affects the measurement speed. This paper presents an absolute phase unwrapping method capable of using only three speckle-embedded phase-shifted patterns for high-speed three-dimensional (3D) shape measurement on a single-camera, single-projector structured light system. The proposed method obtains the wrapped phase of the object from the speckle-embedded three-step phase-shifted patterns. Next, it utilizes the Semi-Global Matching (SGM) algorithm to establish the coarse correspondence between the image of the object with the embedded speckle pattern and the pre-obtained image of a flat surface with the same embedded speckle pattern. Then, a computational framework uses the coarse correspondence information to determine the fringe order pixel by pixel. The experimental results demonstrated that the proposed method can achieve high-speed and high-quality 3D measurements of complex scenes. 
    more » « less
  5. Imaging 3D nano-structures at very high resolution is crucial in a variety of scientific fields. However, due to fundamental limitations of light propagation we can only measure the object indirectly via 2D intensity measurements of the 3D specimen through highly nonlinear projection mappings where a variety of information (including phase) is lost. Reconstruction therefore involves inverting highly nonlinear and seemingly non-invertible mappings. In this paper, we introduce a novel technique where the 3D object is directly reconstructed from an accurate non-linear propagation model. Furthermore, we characterize the ambiguities of this model and leverage a priori knowledge to mitigate their effect and also significantly reduce the required number of measurements and hence the acquisition time. We demonstrate the performance of our algorithm via numerical experiments aimed at nano-scale reconstruction of 3D integrated circuits. Moreover, we provide rigorous theoretical guarantees for convergence to stationarity. 
    more » « less