skip to main content


Title: Agile 3D-Navigation of a Helical Magnetic Swimmer
Rotating miniature magnetic swimmers are de-vices that could navigate within the bloodstream to access remote locations of the body and perform minimally invasive procedures. The rotational movement could be used, for example, to abrade a pulmonary embolus. Some regions, such as the heart, are challenging to navigate. Cardiac and respiratory motions of the heart combined with a fast and variable blood flow necessitate a highly agile swimmer. This swimmer should minimize contact with the walls of the blood vessels and the cardiac structures to mitigate the risk of complications. This paper presents experimental tests of a millimeter-scale magnetic helical swimmer navigating in a blood-mimicking solution and describes its turning capabilities. The step-out frequency and the position error were measured for different values of turn radius. The paper also introduces rapid movements that increase the swimmer's agility and demonstrates these experimentally on a complex 3D trajectory.  more » « less
Award ID(s):
1553063 1646566 1932572
NSF-PAR ID:
10219772
Author(s) / Creator(s):
; ; ; ; ;
Date Published:
Journal Name:
2020 IEEE International Conference on Robotics and Automation (ICRA)
Page Range / eLocation ID:
7638 to 7644
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract The disturbances caused by the blood flow and tissue surface motions are major concerns during the motion planning of an intracardiac robotic catheter. Maintaining a stable and safe contact on the desired ablation point is essential for achieving effective lesions during the ablation procedure. In this paper, a probabilistic formulation of the contact stability and the contact safety for intravascular cardiac catheters under the blood flow and surface motion disturbances is presented. Probabilistic contact stability and contact safety metrics, employing a sample-based representation of the blood flow velocity distribution and the heart motion trajectory, are introduced. Finally, the contact stability and safety for an magnetic resonance imaging-actuated robotic catheter under main pulmonary artery blood flow disturbances and left ventricle surface motion disturbances are analyzed in simulation as example scenarios. 
    more » « less
  2. The segmentation of the ventricular wall and the blood pool in cardiac magnetic resonance imaging (MRI) has been inves- tigated for decades, given its important role for delineation of cardiac functioning and diagnosis of heart diseases. One of the major challenges is that the inner epicardium boundary is not always visible in the image domain, due to the mix- ture of blood and muscle structures, especially at the end of contraction, or systole. To address it, we propose a novel ap- proach for the cardiac segmentation in the short-axis (SAX) MRI: coupled deep neural networks and deformable models. First, a 2D U-Net is adopted for each magnetic resonance (MR) slice, and a 3D U-Net refines the segmentation results along the temporal dimension. Then, we propose a multi- component deformable model to extract accurate contours for both endo- and epicardium with global and local constraints. Finally, a partial blood classification is explored to estimate the presence of boundary pixels near the trabeculae and solid wall, and to avoid moving the endocardium boundary inward. Quantitative evaluation demonstrates the high accuracy, ro- bustness, and efficiency of our approach for the slices ac- quired at different locations and different cardiac phases. 
    more » « less
  3. This study investigates the high speed 3D navigation of rotating millimeter-scale swimmers. The swimmers have a spiral-shaped surface to ensure propulsion. The rotational movement is used for propulsion and, in future work, could provide the power needed to remove blood clots. For instance, an abrasive tip could be used to progressively grind a blood clot. An algorithm to perform 3D control of rotating millimeterscale swimmers was implemented and tested experimentally. The swimmers can follow a trajectory and can navigate without touching the walls inside a tube having a diameter of 15 mm. This diameter is smaller than the average diameter of the distal descending aorta, which is the smallest section of the aorta. Several swimmers designs were built and tested. The maximum velocity recorded for our best swimmer was 103.6 mm/s with a rotational speed of 477.5 rotations per second. 
    more » « less
  4. Left ventricular assist devices (LVADs) have been used for end-stage heart failure patients as a therapeutic option. The aortic valve plays a critical role in heart failure and its treatment with a LVAD. The cardiovascular-LVAD model is often used to investigate the physiological demands required by patients and predict the hemodynamic of the native heart supported with a LVAD. As it is a “ bridge-to-recovery ” treatment, it is important to maintain appropriate and active dynamics of the aortic valve and the cardiac output of the native heart, which requires that the LVAD pump be adjusted so that a proper balance between the blood contributed through the aortic valve and the pump is maintained. In this paper, we investigate how the pump power of the LVAD pump can affect the dynamic behaviors of the aortic valve for different levels of activity and different severities of heart failure. Our objective is to identify a critical value of the pump power (i.e., breakpoint ) to ensure that the LVAD pump does not take over the pumping function in the cardiovascular-pump system and share the ejected blood with the left ventricle to help the heart to recover. In addition, the hemodynamic often involves variability due to patients’ heterogeneity and the stochastic nature of the cardiovascular system. The variability poses significant challenges to understanding dynamic behaviors of the aortic valve and cardiac output. A generalized polynomial chaos (gPC) expansion is used in this work to develop a stochastic cardiovascular-pump model for efficient uncertainty propagation, from which it is possible to rapidly calculate the variance in the aortic valve opening duration and the cardiac output in the presence of variability. The simulation results show that the gPC-based cardiovascular-pump model is a reliable platform that can provide useful information to understand the effect of the LVAD pump on the hemodynamic of the heart. 
    more » « less
  5. null (Ed.)
    Some micro-organisms and artificial micro-swimmers propel at low Reynolds numbers (Re) via the interaction of their flexible appendages with the surrounding fluid. While their locomotion has been extensively studied with a Newtonian fluid assumption, in realistic biological environments these micro-swimmers invariably encounter rheologically complex fluids. In particular, many biological fluids such as blood and different types of mucus have shear-thinning viscosities. The influence of this ubiquitous non-Newtonian rheology on the performance of flexible swimmers remains largely unknown. Here, we present a first study to examine how shear-thinning rheology alters the fluid-structure interaction and hence the propulsion performance of elastic swimmers at low Re. Via a simple elastic swimmer actuated magnetically, we demonstrate that shear-thinning rheology can either enhance or hinder elastohydrodynamic propulsion, depending on the intricate interplay between elastic and viscous forces as well as the magnetic actuation. We also use a reduced-order model to elucidate the mechanisms underlying the enhanced and hindered propulsion observed in different physical regimes. These results and improved understanding could guide the design of flexible micro-swimmers in non-Newtonian fluids. 
    more » « less