skip to main content


Title: Compliant 3D frameworks instrumented with strain sensors for characterization of millimeter-scale engineered muscle tissues

Tissue-on-chip systems represent promising platforms for monitoring and controlling tissue functions in vitro for various purposes in biomedical research. The two-dimensional (2D) layouts of these constructs constrain the types of interactions that can be studied and limit their relevance to three-dimensional (3D) tissues. The development of 3D electronic scaffolds and microphysiological devices with geometries and functions tailored to realistic 3D tissues has the potential to create important possibilities in advanced sensing and control. This study presents classes of compliant 3D frameworks that incorporate microscale strain sensors for high-sensitivity measurements of contractile forces of engineered optogenetic muscle tissue rings, supported by quantitative simulations. Compared with traditional approaches based on optical microscopy, these 3D mechanical frameworks and sensing systems can measure not only motions but also contractile forces with high accuracy and high temporal resolution. Results of active tension force measurements of engineered muscle rings under different stimulation conditions in long-term monitoring settings for over 5 wk and in response to various chemical and drug doses demonstrate the utility of such platforms in sensing and modulation of muscle and other tissues. Possibilities for applications range from drug screening and disease modeling to biohybrid robotic engineering.

 
more » « less
Award ID(s):
1635443 1830881
PAR ID:
10225692
Author(s) / Creator(s):
; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ;
Publisher / Repository:
Proceedings of the National Academy of Sciences
Date Published:
Journal Name:
Proceedings of the National Academy of Sciences
Volume:
118
Issue:
19
ISSN:
0027-8424
Page Range / eLocation ID:
Article No. e2100077118
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract

    Drug‐induced cardiotoxicity is regarded as a major hurdle in the early stages of drug development. Although there are various methods for preclinical cardiotoxicity tests, they cannot completely predict the cardiotoxic potential of a compound due to the lack of physiological relevance. Recently, 3D engineered heart tissue (EHT) has been used to investigate cardiac muscle functions as well as pharmacological effects by exhibiting physiological auxotonic contractions. However, there is still no adequate platform for continuous monitoring to test acute and chronic pharmacological effects in vitro. Here, a biohybrid 3D printing method for fabricating a tissue‐sensor platform, composed of a bipillar‐grafted strain gauge sensor and EHT, is first introduced. Two pillars are three‐dimensionally printed as grafts onto a strain gauge‐embedded substrate to promote the EHT contractility and guide the self‐assembly of the EHTs along with the strain gauge. In addition, the integration of a wireless multi‐channel electronic system allows for continuous monitoring of the EHT contractile force by the tissue‐sensor platform and, ultimately, for the observation of the acute and chronic drug effects of cardiotoxicants. In summary, biohybrid 3D printing technology is expected to be a potential fabrication method to provide a next‐generation tissue‐sensor platform for an effective drug development process.

     
    more » « less
  2. Abstract

    While the effects of microgravity on inducing skeletal muscle atrophy have been extensively studied, the impacts of microgravity on myogenesis and its mechanisms remain unclear. In this study, we developed a microphysiological system of engineered muscle tissue (EMT) fabricated using a collagen / Matrigel composite hydrogel and murine skeletal myoblasts. This 3D EMT model allows non-invasive quantitative assessment of contractile function. After applying a 7-day differentiation protocol to induce myotube formation, the EMTs clearly exhibited sarcomerogenesis, myofilament formation, and synchronous twitch and tetanic contractions with electrical stimuli. Using this 3D EMT system, we investigated the effects of simulated microgravity at 10−3 G on myogenesis and contractile function utilizing a random positioning machine. EMTs cultured for 5 days in simulated microgravity exhibited significantly reduced contractile forces, myofiber size, and differential expression of muscle contractile, myogenesis regulatory, and mitochondrial biogenesis-related proteins. These results indicate simulated microgravity attenuates myogenesis, resulting in impaired muscle function.

     
    more » « less
  3. ABSTRACT

    Conventional two‐dimensional (2D) cardiomyocyte differentiation protocols create cells with limited maturity, which impairs their predictive capacity and has driven interest in three‐dimensional (3D) engineered cardiac tissue models of varying maturity and scalability. Cardiac spheroids are attractive high‐throughput models that have demonstrated improved functional and transcriptional maturity over conventional 2D differentiations. However, these 3D models still tend to have limited contractile and electrical maturity compared to highly engineered cardiac tissues; hence, we incorporated a library of conductive polymer microfibers in cardiac spheroids to determine if fiber properties could accelerate maturation. Conductive microfibers improved contractility parameters of cardiac spheroids over time versus nonconductive fibers, specifically, when they were short, for example, 5 μm, and when there was moderate fiber mass per spheroid, for example, 20 μg. Spheroids with optimal conductive microfiber length and concentration developed a thicker ring‐like perimeter and a less compacted cavity, improving their contractile work compared to control cardiac spheroids. Functional improvements correlated with increased expression of contractility and calcium handling‐related cardiac proteins, as well as improved calcium handling abilities and drug response. Taken together, these data suggest that conductive microfibers can improve cardiac spheroid performance to improve cardiac disease modeling.

     
    more » « less
  4. Abstract

    Low-temperature biopreservation and 3D tissue engineering present two differing routes towards eventual on-demand access to transplantable biologics, but recent advances in both fields present critical new opportunities for crossover between them. In this work, we demonstrate sub-zero centigrade preservation and revival of autonomously beating three-dimensional human induced pluripotent stem cell (hiPSC)-derived cardiac microtissues via isochoric supercooling, without the use of chemical cryoprotectants. We show that these tissues can cease autonomous beating during preservation and resume it after warming, that the supercooling process does not affect sarcomere structural integrity, and that the tissues maintain responsiveness to drug exposure following revival. Our work suggests both that functional three dimensional (3D) engineered tissues may provide an excellent high-content, low-risk testbed to study complex tissue biopreservation in a genetically human context, and that isochoric supercooling may provide a robust method for preserving and reviving engineered tissues themselves.

     
    more » « less
  5. Abstract

    Three‐dimensional (3D) skeletal muscle constructs engineered from myogenic progenitors derived from human pluripotent stem cells (hPSCs) have a wide range of applications, but to date, such constructs generate lower specific tetanic force than adult human muscles. Methods enhancing functional muscle differentiation and force generation of these constructs are highly desirable. The finding of this study is that addition of the supplements in the endothelial cell growth medium‐2 (EGM‐2) to the myogenic differentiation medium can substantially enhance contractile force generation. For constructs differentiated for 4 weeks, addition of the EGM‐2 supplements in the first 2 weeks leads to tenfold and sevenfold increases in twitch and tetanic forces, respectively. The specific tetanic force generated by these constructs is 33 mN mm−2, which is significantly higher than previously reported. These constructs show wider myotubes and higher gene expression levels for all skeletal muscle‐specific myosin heavy chain isoforms, suggesting that a more mature differentiation stage of the cells underlies the greater contractile force generation. The constructs exposed to these supplements for 4 weeks do not generate as high contractile forces, suggesting that prolonged treatment is not beneficial. These results suggest that temporal conditioning with the EGM‐2 supplements assists functional development of hPSC‐derived skeletal muscle constructs.

     
    more » « less