Title: Evaluation of Wood Composite Sandwich Panels as a Promising Renewable Building Material
During this study, full-size wood composite sandwich panels, 1.2 m by 2.4 m (4 ft by 8 ft), with a biaxial corrugated core were evaluated as a building construction material. Considering the applications of this new building material, including roof, floor, and wall paneling, sandwich panels with one and two corrugated core(s) were fabricated and experimentally evaluated. Since primary loads applied on these sandwich panels during their service life are live load, snow load, wind, and gravity loads, their bending and compression behavior were investigated. To improve the thermal characteristics, the cavities within the sandwich panels created by the corrugated geometry of the core were filled with a closed-cell foam. The R-values of the sandwich panels were measured to evaluate their energy performance. Comparison of the weight indicated that fabrication of a corrugated panel needs 74% less strands and, as a result, less resin compared to a strand-based composite panel, such as oriented strand board (OSB), of the same size and same density. Bending results revealed that one-layer core sandwich panels with floor applications under a 4.79 kPa (100 psf) bending load are able to meet the smallest deflection limit of L/360 when the span length (L) is 137.16 cm (54 in) or less. The ultimate capacity of two-layered core sandwich panels as a wall member was 94% and 158% higher than the traditional walls with studs under bending and axial compressive loads, respectively. Two-layered core sandwich panels also showed a higher ultimate capacity compared to structural insulated panels (SIP), at 470% and 235% more in bending and axial compression, respectively. Furthermore, normalized R-values, the thermal resistance, of these sandwich panels, even with the presence of thermal bridging due to the core geometry, was about 114% and 109% higher than plywood and oriented strand board, respectively.  more » « less
Award ID(s):
1150316
PAR ID:
10228093
Author(s) / Creator(s):
; ;
Date Published:
Journal Name:
Materials
Volume:
14
Issue:
8
ISSN:
1996-1944
Page Range / eLocation ID:
2083
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Strands produced from small-diameter timbers of lodgepole and ponderosa pine were used to fabricate a composite sandwich structure as a replacement for traditional building envelope materials, such as roofing. It is beneficial to develop models that are verified to predict the behavior of these sandwich structures under typical service loads. When used for building envelopes, these structural panels are subjected to bending due to wind, snow, live, and dead loads during their service life. The objective of this study was to develop a theoretical and a finite element (FE) model to evaluate the elastic bending behavior of the wood-strand composite sandwich panel with a biaxial corrugated core. The effect of shear deformation was shown to be negligible by applying two theoretical models, the Euler–Bernoulli and Timoshenko beam theories. Tensile tests were conducted to obtain the material properties as inputs into the models. Predicted bending stiffness of the sandwich panels using Euler-Bernoulli, Timoshenko, and FE models differed from the experimental results by 3.6%, 5.2%, and 6.5%, respectively. Using FE and theoretical models, a sensitivity analysis was conducted to explore the effect of change in bending stiffness due to intrinsic variation in material properties of the wood composite material. 
    more » « less
  2. Abstract A preliminary experimental evaluation of duration of load and creep effects of lightweight wood-strand sandwich panels (lwW-SSP) was conducted following ASTM D6815-09 to determine the equivalence to the duration of load and creep effects of visually graded lumber as specified in Practice D245. The modulus of rupture (MOR) of lwW-SSP was obtained using four-point bending tests to evaluate their creep and load behavior at three stress levels (15, 40 and 65% of MOR). Two different widths were considered to observe the effect of this parameter. lwW-SSP preformed well under long-term loads, as tertiary creep was not observed at all stress levels and the strain rate decreased over time. The panels met the criteria specified in the standard. None of the specimens failed, the creep rate decreased and the fractional deflection was <2. Accordingly, the duration of load factors of visually graded lumber is applicable to these panels. For the theoretical evaluation of solid wood behavior, viscoelastic models can also be applied to describe the creep behavior of lwW-SSP with wood-strand corrugated cores. An exponential viscoelastic model consisting of five elements accurately approximates the experimental creep behavior of three-dimensional (3D) core sandwich panel. 
    more » « less
  3. This paper focuses on recent advances made in design, development, manufacturing, evaluation and modeling of load bearing fiber reinforced polymer (FRP) composite sandwich panel systems including tongue and groove joints. Several processes have been researched in collaboration with industry partners for production of composite panels, including: 1) pultrusion, 2) high temperature resin spread and infusion, 3) vacuum assisted resin transfer molding (VARTM), and 4) compression molding. The advantages and disadvantages of each process are discussed with emphasis on the high temperature resin infusion process. Composite laminates are characterized in terms of strength and stiffness under tension, bending, and shear in relation to longitudinal and transverse fiber orientations. Thermo-mechanical property variations of the FRP composite sandwich panels including joint responses are presented in terms of: 1) production processes, 2) carbon versus E-glass fiber, 3) vinyl ester versus epoxy, and 4) panel and joint design and efficiency including classical lamination theory. The sandwich panels are evaluated at component and full scales under static four point bending loads and further analyzed using classical finite element models for their mechanical responses. 
    more » « less
  4. null (Ed.)
    Abstract The composite sandwich structures with foam core and fiber-reinforced polymer skin are prone to damage under local impact. The mechanical behavior of sandwich panels (glass fiber-reinforced polymer [GFRP] skin reinforced with lattice webs and syntactic foams core) is studied under crushing load. The crushing behavior, failure modes, and energy absorption are correlated with the number of GFRP layers in facesheets and webs, fiber volume fractions of facesheets in both longitudinal and transverse directions, and density and thickness of syntactic foam. The test results revealed that increasing the number of FRP layers of lattice webs was an effective way to enhance the energy absorption of sandwich panels without remarkable increase in the peak load. Moreover, a three-dimensional finite-element (FE) model was developed to simulate the mechanical behavior of the syntactic foam sandwich panels, and the numerical results were compared with the experimental results. Then, the verified FE model was applied to conduct extensive parametric studies. Finally, based on experimental and numerical results, the optimal design of syntactic foam sandwich structures as energy absorption members was obtained. This study provides theoretical basis and design reference of a novel syntactic foam sandwich structure for applications in bridge decks, ship decks, carriages, airframes, wall panels, anticollision guard rails and bumpers, and railway sleepers. 
    more » « less
  5. This paper documents the testing of six 20 ft × 4 ft × 8 in. (6.1 m × 1.2 m × 203.2 mm) precast, prestressed concrete sandwich panels constructed with continuous rigid insulation and a carbon-fiber-reinforced polymer grid shear transfer mechanism. All panels were identical except for foam type and were cast together on the same prestressing bed. Three of the six panels were fabricated with expanded polystyrene (EPS) foam insulation, and the remaining three panels were fabricated using sandblasted extruded polystyrene (XPS) foam. For each group of three panels, one was tested to failure as a control and two others were cycled 2 million times to 45% of their design ultimate load before failure testing. The tested EPS panels all failed when the applied lateral load was greater than or equal to 100 lb/ft2 (4.79 kPa), which is 2.35 times their design load of 42.5 lb/ft2 (2.03 kPa). The tested XPS panels all failed at the equivalent of 175 lb/ft2 (8.38 kPa) of applied lateral pressure, which is more than 4.0 times their design load of 42.5 lb/ft2. All four panels subjected to fatigue survived 2 million reverse-cyclic lateral load cycles without any visible signs of degradation. 
    more » « less