skip to main content


Title: After the paint has dried: a review of testing techniques for studying the mechanical properties of artists’ paint
Abstract

While the chemistry of artists’ paints has previously been studied and reviewed, these studies only capture a portion of the properties affecting the response of paint materials. The mechanical properties of artists’ paints relate to the deformation response of these materials when a stress is applied. This response is dependent on many factors, such as paint composition, pigment to binder ratio, temperature, relative humidity, and solvent exposure. Here, thirty years of tensile testing data have been compiled into a single dataset, along with the testing conditions, to provide future researchers with easy access to these data as well some general discussion of their trends. Alongside the more commonly used techniques of tensile testing and dynamic mechanical analysis, new techniques have been developed to more fully investigate the mechanical properties, and are discussed along with salient results. The techniques have been divided into two categories: those that are restricted to use on model systems and those that are applicable to historic samples. Techniques applied to model systems (tensile testing, dynamic mechanic analysis, quartz crystal microbalance, vibration studies) require too large of a sample to be taken from art objects or focus on the mechanical properties of the liquid state (shear rheometry). Techniques applied to historic samples incorporate the use of small sample sizes (nanoindentation), optical techniques (laser shearography), computational simulations (finite element analysis), and non-invasive comparative mechanical properties (single-sided nuclear magnetic resonance) to investigate and predict the mechanical properties of paints.

 
more » « less
Award ID(s):
1743748
NSF-PAR ID:
10240277
Author(s) / Creator(s):
; ; ;
Publisher / Repository:
Springer Science + Business Media
Date Published:
Journal Name:
Heritage Science
Volume:
9
Issue:
1
ISSN:
2050-7445
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. IMECE2022-88299 Midwest Engineered Systems Inc. has created a novel laser wire metal deposition process, ADDere manufacturing. ADDere has a much higher deposition rate than powder bed fusion, making it ideal for large components. In this project, the mechanical properties of ADDere printed materials were tested and compared to typical values found in ASM publications to show the quality of materials manufactured by the ADDere printing process. A detailed material analysis was performed on samples made from Ti-6Al-4V and 17-4 PH stainless steel. This work builds upon an earlier study of samples made from 17-4 PH that were produced using a single direction pattern. In this project, the 17-4 PH samples were printed in a cross hatched pattern, and testing results were compared to existing data from single direction samples of the previous research. The Ti-6Al-4V samples were created in two builds. One using the uni-directional method and the other with the crossed pattern. Testing specimens were removed from the samples using a water jet cutter and further machined into ASTM tensile bars and metallurgic mounts to perform a thorough material evaluation. The Ti-6Al-4V sample met the expected values in the ASM literature, and the cross hatched 17-4 PH exhibited a higher hardness and better microstructure than the single direction samples from the previous work. It was also observed that when the Ti64 samples were manufactured in the cross hatched pattern, the properties indicated slight improvement and more homogeneity than those printed in single layer direction. The obtained results indicate that ADDere’s printing process can produce highly refined materials that are customizable with their expected uses. This work showcases an excellent industry collaboration of an undergraduate research experience. 
    more » « less
  2. Transparent wood composites (TWCs) are a new class of light-transmitting wood-based materials composed of a delignified wood template that is infiltrated with a refractive- index-matched polymer resin. Recent research has focused primarily on the fabrication and characterization of single-ply TWCs. However, multi-ply composite laminates are of interest due to the mechanical advantages they impart compared to the single ply. In this work, 1- and 2-ply [0°/90°] TWC laminates were fabricated using a delignified wood template (C) and an acetylated delignified wood template (AC). The optical and mechanical properties of resultant C and AC TWC laminates were determined using ultraviolet-visible spectroscopy (UV-Vis) and tensile testing (5× replicates), respectively. In addition, the ability of classical lamination plate theory and simple rule of mixtures to predict multi-ply tensile modulus and strength, respectively, from ply-level mechanical properties were investigated and are reported herein. Experimental results highlight tradeoffs that exist between the mechanical and optical responses of both unmodified and chemically modified TWCs. Template acetylation reduced the stiffness and strength in the 0° fiber direction by 2.4 GPa and 58.9 MPa, respectively, compared to the unmodified samples. At high wavelengths of light (>515 nm), AC samples exhibited higher transmittance than the C samples. Above 687 nm, the 2-ply AC sample exhibited a higher transmittance than the 1-ply C sample, indicating that thickness-dependent optical constraints can be overcome with improved interfacial interactions. Finally, both predictive models were successful in predicting the elastic modulus and tensile strength response for the 2-ply C and AC samples. 
    more » « less
  3. The formation of lead carboxylates (lead soaps) has been identified as the cause of deterioration of hundreds of oil paintings. Soaps form when heavy metal-containing pigments, for example lead white and lead-tin yellow, react with saturated fatty acids in the oil medium. Understanding the mechanism of the reactions requires chemical information, which can be obtained with solid-state 207Pb, 119Sn and 13C NMR spectroscopy. Using the chemical-shift tensors determined by solid-state NMR we can gain structural insights on the coordination environment of the lead carboxylates and identify and quantify components in a paint film mixture. We have examined the spectroscopy of lead-containing pigments, lead carboxylates, and model paint films that were subjected to accelerated aging. We have also begun to investigate the dynamics of soap formation by 13C NMR spectroscopy. The NMR methods applied to the model paint systems could also be applied to other lead-containing materials. 
    more » « less
  4. Digital image correlation (DIC) is a non-destructive and non-contact optical technique to measure deformation and strain of materials. The method is based on optically tracking the displacements of a speckle pattern created on the material surface. In the case of soft tissues such as mouse aorta, there are several advantages to using DIC since it can provide local, rather than global, deformations and it is suitable for large strain measurements, typical of soft tissues taken to failure [1] [2]. For the optimal use of DIC, several requirements should be met for speckle patterning: 1) randomness, 2) high contrast, 3) appropriate size of speckle in the field of view (3-5 pixels), and 4) firm attachment of speckle to specimen during deformation. In previous DIC studies of soft tissues, the methods employed to create a speckle pattern include the use of an airbrush to spray dye or paint on the specimen, or coating the sample with toner powder. However, biological samples must be partially dehydrated before applying paint which may affect the mechanical properties of the specimen, and toner powder is too hydrophobic to adhere well on specimens when submerged in aqueous solution during mechanical testing. In addition, it is difficult to evenly distribute paint or toner powder on the surface of a hydrated biological specimen [2]. Therefore, a novel method utilizing colloidal gold particles to create a speckle pattern on mouse aorta is proposed in this work. 
    more » « less
  5. null (Ed.)
    In this paper, we report on a novel biocompatible micromechanical bioreactor (actuator and sensor) designed for the in situ manipulation and characterization of live microtissues. The purpose of this study was to develop and validate an application-targeted sterile bioreactor that is accessible, inexpensive, adjustable, and easily fabricated. Our method relies on a simple polydimethylsiloxane (PDMS) molding technique for fabrication and is compatible with commonly-used laboratory equipment and materials. Our unique design includes a flexible thin membrane that allows for the transfer of an external actuation into the PDMS beam-based actuator and sensor placed inside a conventional 35 mm cell culture Petri dish. Through computational analysis followed by experimental testing, we demonstrated its functionality, accuracy, sensitivity, and tunable operating range. Through time-course testing, the actuator delivered strains of over 20% to biodegradable electrospun poly (D, L-lactide-co-glycolide) (PLGA) 85:15 non-aligned nanofibers (~91 µm thick). At the same time, the sensor was able to characterize time-course changes in Young’s modulus (down to 10–150 kPa), induced by an application of isopropyl alcohol (IPA). Furthermore, the actuator delivered strains of up to 4% to PDMS monolayers (~30 µm thick), simultaneously characterizing their elastic modulus up to ~2.2 MPa. The platform repeatedly applied dynamic (0.23 Hz) tensile stimuli to live Human Dermal Fibroblast (HDF) cells for 12 hours (h) and recorded the cellular reorientation towards two angle regimes, with averages of −58.85° and +56.02°. The device biocompatibility with live cells was demonstrated for one week, with no signs of cytotoxicity. We can conclude that our PDMS bioreactor is advantageous for low-cost tissue/cell culture micromanipulation studies involving mechanical actuation and characterization. Our device eliminates the need for an expensive experimental setup for cell micromanipulation, increasing the ease of live-cell manipulation studies by providing an affordable way of conducting high-throughput experiments without the need to open the Petri dish, reducing manual handling, cross-contamination, supplies, and costs. The device design, material, and methods allow the user to define the operational range based on their targeted samples/application. 
    more » « less