Title: Hydroxyapatite reinforced Ti6Al4V composites for load-bearing implants
Titanium has been used in various biomedical applications; however, titanium exhibits poor wear resistance, and its bioinert surface slows osseointegration in vivo. In this study, directed energy deposition (DED)-based additive manufacturing (AM) was used to process hydroxyapatite (HA) reinforced Ti6Al4V (Ti64) composites to improve biocompatibility and wear resistance simultaneously. Electron micrographs of the composites revealed dense microstructures where HA is observed at the β-phase grain boundaries. Hardness was observed to increase by 57% and 71% for 2 and 3 wt.% HA in Ti64 composites, respectively. XRD analysis revealed no change in the present phases. Tribological studies revealed an increase in contact resistance due to in situ HA-based tribofilm formation, reduction in wear rate when testing in DMEM with a ZrO2 counter wear ball, ˂1% wear ball volume loss, and suppression of cohesive failure of the Ti matrix. Histomorphometric analysis from a rat distal femur study revealed an increase in the osteoid surface over the bone surface (OS/BS) for 3 wt.% HA composite over the control Ti64 from 9 ± 1% to 14 ± 1%. Shear modulus was also observed to increase from 17 ± 3 MPa for control Ti64 to 32 ± 5 MPa for the 3 wt.% HA composite more » after 5 weeks. Our study demonstrates that the addition of HA in Ti64 can simultaneously improve bone tissue-implant response and wear resistance. « less
Authors:
; ; ;
Award ID(s):
1934230
Publication Date:
NSF-PAR ID:
10282688
Journal Name:
Acta biomaterialia
Volume:
123
Page Range or eLocation-ID:
379-392
ISSN:
1742-7061
Sponsoring Org:
National Science Foundation
More Like this
  1. INTRODUCTION: Orthopedic implants are important therapeutic devices for the management of a wide range of orthopedic conditions. However, bacterial infections of orthopedic implants remain a major problem, and not an uncommon one, leading to an increased rate of osteomyelitis, sepsis, implant failure and dysfunction, etc. Treating these infections is more challenging as the causative organism protects itself by the production of a biofilm over the implant’s surface (1). Infections start by the adhesion and colonization of pathogenic bacteria such as Staphylococcus aureus (SA), Staphylococcus epidermidis (SE), Escherichia coli (E. coli), Methicillin-Resistant Staphylococcus aureus (MRSA), and Multi-Drug Resistant Escherichia coli (MDRmore »E. coli) on the implant’s surfaces. Specifically, Staphylococcus comprises up to two-thirds of all pathogens involved in orthopedic implant infections (2). However, bacterial surface adhesion is a complex process influenced by several factors such as chemical composition, hydrophobicity, magnetization, surface charge, and surface roughness of the implant (3). Considering the intimate association between bacteria and the implant surface, we measured the effect of stainless-steel surface properties on bacterial surface attachment and subsequent formation of biofilms controlling above mentioned factors. METHODS: The prominent bacteria responsible for orthopedic implant infections (SA, SE, E. coli, MRSA, and MDR E. coli) were used in this study. We were able to control the grain size of medical grade 304 and 316L stainless steel without altering their chemical composition (grain size range= 20μm-200nm) (4). Grain size control affected the nano-topography of the material surfaces which was measured by an Atomic Force Microscope (AFM). Grain sizes, such as 0.2, 0.5, 1, 2, 3, 9, and 10 μm, were used both polished and non-polished. All the stainless-steel samples were cleaned by treating with acetone and ethanol under sonication. Triplicates of all polished and non-polished samples with different grain sizes were subjected to magnetization of DM, 0.1T, 0.5T, and 1T, before seeding them with the bacteria. Controls were used in the form of untreated samples. Bacterial were grown in Tryptic Soy Broth (TSB). An actively growing bacterial suspension was seeded onto the stainless-steel discs into 24-well micro-titer plates and kept for incubation. After 24 hours of incubation, the stainless-steel discs were washed with Phosphate Buffer Saline (PBS) to remove the plankton bacteria and allow the sessile bacteria in the biofilm to remain. The degree of development of the bacterial biofilms on the stainless-steel discs were measured using spectrophotometric analysis. For this, the bacterial biofilm was removed from the stainless steel by sonication. The formation of biofilms was also determined by performing a biofilm staining method using Safranin. RESULTS SECTION: AFM results revealed a slight decrease in roughness by decreasing the grain size of the material. Moreover, the samples were segregated into two categories of polished and non-polished samples, in which polishing decreased roughness significantly. After careful analysis we found out that polished surfaces showed a higher degree for biofilm formation in comparison to the non-polished ones. We also observed that bacteria showed a higher rate for biofilm formation for the demagnetized samples, whereas 0.5T magnetization showed the least amount of biofilm formation. After 0.5T, there was no significant change in the rate of biofilm formation on the stainless-steel samples. Altogether, stainless steel samples containing 0.5 μm and less grainsize, and magnetized with 0.5 tesla and stronger magnets demonstrated the least degree of biofilm formation. DISCUSSION: In summary, the results demonstrate that controlling the grain size of medical grade stainless steel can control and mitigate bacterial responses on, and thus possibly infections of, orthopedic implants or other implantable devices. The research was funded by Komatsuseiki Kosakusho Co., Ltd (KSJ: Japan) SIGNIFICANCE/CLINICAL RELEVANCE: Orthopedic implants that more than 70% of them are made of metals (i.e., stainless steel, titanium, and cobalt-chromium alloys) are failing through loosening and breakage due to their limited mechanical properties. On the other hand, the risk of infection for these implants and its financial burden on our society is undeniable. We have seen that our uniformly nanograined stainless steel shows improved mechanical properties (i.e., higher stiffness, hardness, fatigue) as compared to conventional stainless steel along with the reduction of biofilm formation on its surface. These promising results made us to peruse the development of nanograined titanium and cobalt-chromium alloys for resolving the complications of orthopedic implants.« less
  2. To simulate global mercury (Hg) dynamics in chemical transport models (CTMs), surface-atmosphere exchange of gaseous elemental mercury, Hg 0 , is often parameterized based on resistance-based dry deposition schemes coupled with a re-emission function, mainly from soils. Despite extensive use of this approach, direct evaluations of this implementation against field observations of net Hg 0 exchange are lacking. In this study, we evaluate an existing net exchange parameterization (referred to here as the base model) by comparing modeled fluxes of Hg 0 to fluxes measured in the field using micrometeorological techniques. Comparisons were performed in two terrestrial ecosystems: a grasslandmore »site in Switzerland and an Arctic tundra site in Alaska, U.S., each including summer and winter seasons. The base model included the dry deposition and soil re-emission parameterizations from Zhang et al. (2003) and the global CTM GEOS-Chem, respectively. Comparisons of modeled and measured Hg 0 fluxes showed large discrepancies, particularly in the summer months when the base model overestimated daytime net deposition by approximately 9 and 2 ng m −2 h −1 at the grassland and tundra sites, respectively. In addition, the base model was unable to capture a measured nighttime net Hg 0 deposition and wintertime deposition. We conducted a series of sensitivity analyses and recommend that Hg simulations using CTMs: (i) reduce stomatal uptake of Hg 0 over grassland and tundra in models by a factor 5–7; (ii) increase nighttime net Hg 0 deposition, e.g. , by increasing ground and cuticular uptake by reducing the respective resistance terms by factors of 3–4 and 2–4, respectively; and (iii) implement a new soil re-emission parameterization to produce larger daytime emissions and lower nighttime emissions. We also compared leaf Hg 0 uptake over the growing season estimated by the dry deposition model against foliar Hg measurements, which revealed good agreement with the measured leaf Hg concentrations after adjusting the base model as suggested above. We conclude that the use of resistance-based models combined with the new soil re-emission flux parameterization is able to reproduce observed diel and seasonal patterns of Hg 0 exchange in these ecosystems. This approach can be used to improve model parameterizations for other ecosystems if flux measurements become available.« less
  3. Recent advances in the processing of wear-resistant calcium-phosphate reinforced CoCrMo composites for articulating surface applications has necessitated further investigation of performance in biological conditions relevant to patient applications. To this end, CoCrMo composites containing calcium phosphate in the form of hydroxyapatite (HA) were manufactured to study the influence of the reinforcing phase on the tribofilm formation in biologically-relevant conditions. The CoCrMo-HA composites were processed using a laser engineered net shaping (LENS™) additive manufacturing (AM) system with three distinctive compositions: CoCrMo-0%HA, CoCrMo-1%HA, and CoCrMo-3%HA. Extensive wear testing of the CoCrMo-HA composites was carried out in DMEM (cell media) and DMEM +more »Hyaluronic acid (found naturally in synovial fluid). Wear tests were performed at loads ranging from 5N to 20N, and wear media was measured post-test using ICP-MS techniques for the release of Co and Cr ions. During testing, all coefficients of friction remained in the 0.15-0.25 range, which was lower than the previously reported 0.50-0.75 range in DI water, indicating that the DMEM + hyaluronic acid media plays a significant role in reducing frictional contact. At loads higher than 15N, the HA-tribofilm exhibited a breakdown resulting in higher wear rates but still lower overall ion release in comparison to the CoCrMo control composition. Our results indicate that CoCrMo alloys with HA addition can significantly reduce wear rates and ion release even in the presence of naturally-occurring synovial-fluid friction-reducing constituents.« less
  4. Abstract
    Excessive phosphorus (P) applications to croplands can contribute to eutrophication of surface waters through surface runoff and subsurface (leaching) losses. We analyzed leaching losses of total dissolved P (TDP) from no-till corn, hybrid poplar (Populus nigra X P. maximowiczii), switchgrass (Panicum virgatum), miscanthus (Miscanthus giganteus), native grasses, and restored prairie, all planted in 2008 on former cropland in Michigan, USA. All crops except corn (13 kg P ha−1 year−1) were grown without P fertilization. Biomass was harvested at the end of each growing season except for poplar. Soil water at 1.2 m depth was sampled weekly to biweekly for TDP determination during March–November 2009–2016More>>
  5. Polymer composites with small amount of CNTs (< 5 wt%) have been studied as a light-weight wear-resistant material with low friction, among other applications, but their modulus improvement often plateaus or diminishes with increasing CNT fraction due to agglomeration. Here, polymer nanocomposites were fabricated with randomly oriented or aligned CNTs across their volume (up to 5 mm length) by CNT surface diazotization and by static magnetic field application (400 G for 40 min). With the improved CNT dispersion and thus less agglomeration, the reduced moduli of PNCs stayed improved with addition of up to 1 vol% (or 1.3 wt%) ofmore »CNTs. In this work, the PNCs with randomly oriented CNTs exhibited higher stiffness than the PNCs with magnetically aligned and assembled CNTs, indicating again the negative effect of CNT agglomeration on stiffness. In future, other CNT structuring methods with controlled inter-CNT contacts will be conducted to dissociate alignment from local agglomeration of CNTs and thus to simultaneously improve hardness and modulus of PNCs with small CNT addition.« less