skip to main content


Title: Greater aridity increases the magnitude of urban nighttime vegetation-derived air cooling
Abstract

High nighttime urban air temperatures increase health risks and economic vulnerability of people globally. While recent studies have highlighted nighttime heat mitigation effects of urban vegetation, the magnitude and variability of vegetation-derived urban nighttime cooling differs greatly among cities. We hypothesize that urban vegetation-derived nighttime air cooling is driven by vegetation density whose effect is regulated by aridity through increasing transpiration. We test this hypothesis by deploying microclimate sensors across eight United States cities and investigating relationships of nighttime air temperature and urban vegetation throughout a summer season. Urban vegetation decreased nighttime air temperature in all cities. Vegetation cooling magnitudes increased as a function of aridity, resulting in the lowest cooling magnitude of 1.4 °C in the most humid city, Miami, FL, and 5.6 °C in the most arid city, Las Vegas, NV. Consistent with the differences among cities, the cooling effect increased during heat waves in all cities. For cities that experience a summer monsoon, Phoenix and Tucson, AZ, the cooling magnitude was larger during the more arid pre-monsoon season than during the more humid monsoon period. Our results place the large differences among previous measurements of vegetation nighttime urban cooling into a coherent physiological framework dependent on plant transpiration. This work informs urban heat risk planning by providing a framework for using urban vegetation as an environmental justice tool and can help identify where and when urban vegetation has the largest effect on mitigating nighttime temperatures.

 
more » « less
Award ID(s):
1924288
NSF-PAR ID:
10362108
Author(s) / Creator(s):
; ; ; ; ; ; ; ; ; ; ; ; ; ;
Publisher / Repository:
IOP Publishing
Date Published:
Journal Name:
Environmental Research Letters
Volume:
16
Issue:
3
ISSN:
1748-9326
Page Range / eLocation ID:
Article No. 034011
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract

    Urban greening is often proposed for urban heat island (UHI) mitigation because vegetation provides shade and increases evapotranspiration. However, vegetation has lower albedo and higher emissivity than the bare soil it often replaces, which increases incoming energy fluxes. Here, we use the Weather Research and Forecasting model to quantify and compare the albedo and non‐albedo effects (i.e., changes in emissivity, surface roughness, and evaporative fluxes) of urban greening in the Los Angeles Basin under policy relevant urban greening scenarios. When albedo‐induced effects were included in the model, daytime surface temperatures in urban areas warmed by 0.70 ± 0.89°C with increases in the sensible heat flux outweighing increases in the latent heat flux from increased evapotranspiration. In contrast, daytime surface temperatures cooled by 0.27 ± 0.72°C when the albedo‐induced effects were ignored. At night, including albedo‐induced effects of urban greening resulted in only half the cooling modeled in the non‐albedo simulations. Near surface air temperatures also had contrasting model results, with nighttime cooling of 0.21 ± 0.47°C outweighing slight daytime warming of 0.04 ± 0.32°C in the non‐albedo simulations and daytime warming of 0.33 ± 0.41°C outweighing slight nighttime cooling of 0.05 ± 0.46°C in the albedo simulations. Our results reveal the critical role that albedo plays in determining the net surface climate effects of urban greening. Reductions in albedo from urban greening should be carefully considered by policy makers and urban planners, especially as high albedo roofs and pavements are simultaneously being deployed for UHI mitigation in many cities.

     
    more » « less
  2. Abstract As a consequence of the warm and humid climate of tropical coastal regions, there is high energy demand year-round due to air conditioning to maintain indoor comfort levels. Past and current practices are focused on mitigating peak cooling demands by improving heat balances by using efficient building envelope technologies, passive systems, and demand side management strategies. In this study, we explore city-scale solar photovoltaic (PV) planning integrating information on climate, building parameters and energy models, and electrical system performance, with added benefits for the tropical coastal city of San Juan, Puerto Rico. Energy balance on normal roof, flush-mounted PV roof, and tilted PV roof are used to determine PV power generation, air, and roof surface temperatures. To scale up the application to the whole city, we use the urbanized version of the Weather Research and Forecast (WRF) model with the building effect parameterization (BEP) and the building energy model (BEM). The city topology is represented by the World Urban Database Access Portal Tool (WUDAPT), local climate zones (LCZs) for urban landscapes. The modeled peak roof temperature is maximum for normal roof conditions and minimum when inclined PV is installed on a roof. These trends are followed by the building air conditioning (AC) demand from urbanized WRF, maximum for normal roof and minimum for inclined roof-mounted PV. The net result is a reduced daytime Urban Heat Island (UHI) for horizontal and inclined PV roof and increased nighttime UHI for the horizontal PV roof as compared with the normal roof. The ratio between coincident AC demand and PV production for the entire metropolitan region is further analyzed reaching 20% for compact low rise and open low rise buildings due to adequate roof area but reaches almost 100% for compact high rise and compact midrise buildings class, respectively. 
    more » « less
  3. Abstract In this work, we investigate the effect of areawide building retrofitting on summertime, street-level outdoor temperatures in an urban district in Berlin, Germany. We perform two building-resolving, weeklong large-eddy simulations: one with nonretrofitted buildings and the other with retrofitted buildings in the entire domain to meet today’s energy efficiency standards. The comparison of the two simulations reveals that the mean outdoor temperatures are higher with retrofitted buildings during daytime conditions. This behavior is caused by the much smaller inertia of the outermost roof/wall layer in the retrofitting case, which is thermally decoupled from the inner roof/wall layers by an insulation layer. As a result, the outermost layer heats up more rigorously during the daytime, leading to increased sensible heat fluxes into the atmosphere. During the nighttime, the outermost layer’s temperature drops down faster, resulting in cooling of the atmosphere. However, as the simulation progresses, the cooling effect becomes smaller and the warming effect becomes larger. After 1 week, we find the mean temperatures to be 4 K higher during the daytime while the cooling effects become negligible. Significance Statement Building retrofitting is taking place in Europe and other continents as a measure to reduce energy consumption. The change in the building envelope directly influences the urban atmosphere. Our study reveals that areawide retrofitting in a German city district can have negative effects on the outdoor microclimate in summer by causing higher air temperatures. 
    more » « less
  4. Abstract

    Urban heat islands (UHIs) may increase the likelihood that frost sensitive plants will escape freezing nighttime temperatures in late spring and early fall. Using data from 151 temperature sensors in the Madison, Wisconsin, region during March 2012–October 2016, we found that during time periods when the National Weather Service (NWS) issued freeze warnings (threshold of 0.0°C) or frost advisories (threshold of 2.22°C) were valid, temperatures in Madison’s most densely populated, built-up areas often did not fall below the respective temperature thresholds. Urban locations had a mean minimum temperature of 0.72° and 1.39°C for spring and fall freeze warnings, respectively, compared to −0.52° and −0.53°C for rural locations. On average, 31% of the region’s land area experienced minimum temperatures above the respective temperature thresholds during freeze warnings and frost advisories, and the likelihood of temperatures falling below critical temperature thresholds increased as the distance away from core urban centers increased. The urban–rural temperature differences were greatest in fall compared to spring, and when sensor temperatures did drop below thresholds, the maximum time spent at or below thresholds was highest for rural locations during fall freeze warnings (6.2 h) compared to urban locations (4.8 h). These findings potentially have widely varying implications for the general public and industry. UHIs create localized, positive perturbations to nighttime temperatures that are difficult to account for in forecasts; therefore, freeze warnings and frost advisories may have varying degrees of verification in medium-sized cities like Madison, Wisconsin, that are surrounded by cropland and natural vegetation.

    Significance Statement

    The purpose of this study was to understand whether the urban heat island effect in Madison, Wisconsin, creates localized temperature patterns where county-scale frost advisories and freeze warnings may not verify. Approximately one-third of Madison’s urban core area and most densely populated region experienced temperatures that were consistently above critical low temperature thresholds. This is important because gardening and crop management decisions are responsive to the perceived risk of cold temperatures in spring and fall that can damage or kill plants. These results suggest that urban warming presents forecast challenges to the issuance of frost advisories and freeze warnings, supporting the need for improved numerical weather prediction at higher spatial resolution to account for complex urban meteorology.

     
    more » « less
  5. Abstract

    Humans’ essential ability to combat heat stress through sweat-based evaporative cooling is modulated by ambient air temperature and humidity, making humid heat a critical factor for human health. In this study, we relate the occurrence of extreme humid heat in two focus regions to two related modes of intraseasonal climate variability: the Madden–Julian oscillation (MJO) and the boreal summer intraseasonal oscillation (BSISO). In the Persian Gulf and South Asia during the May–June and July–August seasons, wet-bulb temperatures of 28°C are found to be almost twice as likely during certain oscillation phases than in others. Variations in moisture are found, to varying degrees, to be an important ingredient in anomalously high wet-bulb temperatures in all three areas studied, influenced by distinct local circulation anomalies. In the Persian Gulf, weakening of climatological winds associated with the intraseasonal oscillation’s propagating center of convection allows for anomalous onshore advection of humid air. Anomalously high wet-bulb temperatures in the northwestern region of South Asia are closely aligned with positive specific humidity anomalies associated with the convectively active phase of the oscillation. On the southeastern coast of India, high wet-bulb temperatures are associated with convectively inactive phases of the intraseasonal oscillation, suggesting that they may be driven by increased surface insolation and reduced evaporative cooling during monsoon breaks. Our results aid in building a foundation for subseasonal predictions of extreme humid heat in regions where it is highly impactful.

    Significance Statement

    Understanding when and why extreme humid heat occurs is essential for informing public health efforts protecting against heat stress. This analysis works to improve our understanding of humid heat variability in two at-risk regions, the Persian Gulf and South Asia. By exploring how subseasonal oscillations affect daily extreme events, this analysis helps bridge the prediction gap between weather and climate. We find that extreme humid heat is more than twice as likely during specific phases of these oscillations than in others. Extremes depend to different extents upon combinations of above-average temperature and humidity. This new knowledge of the regional drivers of humid heat variability is important to better prepare for the increasingly widespread health and socioeconomic impacts of heat stress.

     
    more » « less