skip to main content


Title: Ultrasound Sensing Can Improve Continuous Classification of Discrete Ambulation Modes Compared to Surface Electromyography
Clinical translation of “intelligent” lower-limb assistive technologies relies on robust control interfaces capable of accurately detecting user intent. To date, mechanical sensors and surface electromyography (EMG) have been the primary sensing modalities used to classify ambulation. Ultrasound (US) imaging can be used to detect user-intent by characterizing structural changes of muscle. Our study evaluates wearable US imaging as a new sensing modality for continuous classification of five discrete ambulation modes: level, incline, decline, stair ascent, and stair descent ambulation, and benchmarks performance relative to EMG sensing. Ten able-bodied subjects were equipped with a wearable US scanner and eight unilateral EMG sensors. Time-intensity features were recorded from US images of three thigh muscles. Features from sliding windows of EMG signals were analyzed in two configurations: one including 5 EMG sensors on muscles around the thigh, and another with 3 additional sensors placed on the shank. Linear discriminate analysis was implemented to continuously classify these phase-dependent features of each sensing modality as one of five ambulation modes. US-based sensing statistically improved mean classification accuracy to 99.8% (99.5-100% CI) compared to 8-EMG sensors (85.8%; 84.0-87.6% CI) and 5-EMG sensors (75.3%; 74.5-76.1% CI). Further, separability analyses show the importance of superficial and deep US information for stair classification relative to other modes. These results are the first to demonstrate the ability of US-based sensing to classify discrete ambulation modes, highlighting the potential for improved assistive device control using less widespread, less superficial and higher resolution sensing of skeletal muscle.  more » « less
Award ID(s):
2109635
NSF-PAR ID:
10298230
Author(s) / Creator(s):
Date Published:
Journal Name:
IEEE transactions on biomedical engineering
ISSN:
1558-2531
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Research on robotic lower-limb assistive devices over the past decade has generated autonomous, multiple degree-of-freedom devices to augment human performance during a variety of scenarios. However, the increase in capabilities of these devices is met with an increase in the complexity of the overall control problem and requirement for an accurate and robust sensing modality for intent recognition. Due to its ability to precede changes in motion, surface electromyography (EMG) is widely studied as a peripheral sensing modality for capturing features of muscle activity as an input for control of powered assistive devices. In order to capture features that contribute to muscle contraction and joint motion beyond muscle activity of superficial muscles, researchers have introduced sonomyography, or real-time dynamic ultrasound imaging of skeletal muscle. However, the ability of these sonomyography features to continuously predict multiple lower-limb joint kinematics during widely varying ambulation tasks, and their potential as an input for powered multiple degree-of-freedom lower-limb assistive devices is unknown. The objective of this research is to evaluate surface EMG and sonomyography, as well as the fusion of features from both sensing modalities, as inputs to Gaussian process regression models for the continuous estimation of hip, knee and ankle angle and velocity during level walking, stair ascent/descent and ramp ascent/descent ambulation. Gaussian process regression is a Bayesian nonlinear regression model that has been introduced as an alternative to musculoskeletal model-based techniques. In this study, time-intensity features of sonomyography on both the anterior and posterior thigh along with time-domain features of surface EMG from eight muscles on the lower-limb were used to train and test subject-dependent and task-invariant Gaussian process regression models for the continuous estimation of hip, knee and ankle motion. Overall, anterior sonomyography sensor fusion with surface EMG significantly improved estimation of hip, knee and ankle motion for all ambulation tasks (level ground, stair and ramp ambulation) in comparison to surface EMG alone. Additionally, anterior sonomyography alone significantly improved errors at the hip and knee for most tasks compared to surface EMG. These findings help inform the implementation and integration of volitional control strategies for robotic assistive technologies.

     
    more » « less
  2. Many people struggle with mobility impairments due to lower limb amputations. To participate in society, they need to be able to walk on a wide variety of terrains, such as stairs, ramps, and level ground. Current lower limb powered prostheses require different control strategies for varying ambulation modes, and use data from mechanical sensors within the prosthesis to determine which ambulation mode the user is in. However, it can be challenging to distinguish between ambulation modes. Efforts have been made to improve classification accuracy by adding electromyography information, but this requires a large number of sensors, has a low signal-to-noise ratio, and cannot distinguish between superficial and deep muscle activations. An alternative sensing modality, A-mode ultrasound, can detect and distinguish between changes in superficial and deep muscles. It has also shown promising results in upper limb gesture classification. Despite these advantages, A-mode ultrasound has yet to be employed for lower limb activity classification. Here we show that A- mode ultrasound can classify ambulation mode with comparable, and in some cases, superior accuracy to mechanical sensing. In this study, seven transfemoral amputee subjects walked on an ambulation circuit while wearing A-mode ultrasound transducers, IMU sensors, and their passive prosthesis. The circuit consisted of sitting, standing, level-ground walking, ramp ascent, ramp descent, stair ascent, and stair descent, and a spatial–temporal convolutional network was trained to continuously classify these seven activities. Offline continuous classification with A-mode ultrasound alone was able to achieve an accuracy of 91.8±3.4%, compared with 93.8±3.0%, when using kinematic data alone. Combined kinematic and ultrasound produced 95.8±2.3% accuracy. This suggests that A-mode ultrasound provides additional useful information about the user’s gait beyond what is provided by mechanical sensors, and that it may be able to improve ambulation mode classification. By incorporating these sensors into powered prostheses, users may enjoy higher reliability for their prostheses, and more seamless transitions between ambulation modes. 
    more » « less
  3. Robotic prostheses and powered exoskeletons are novel assistive robotic devices for modern medicine. Muscle activity sensing plays an important role in controlling assistive robotics devices. Most devices measure the surface electromyography (sEMG) signal for myoelectric control. However, sEMG is an integrated signal from muscle activities. It is difficult to sense muscle movements in specific small regions, particularly at different depths. Alternatively, traditional ultrasound imaging has recently been proposed to monitor muscle activity due to its ability to directly visualize superficial and at-depth muscles. Despite their advantages, traditional ultrasound probes lack wearability. In this paper, a wearable ultrasound (US) transducer, based on lead zirconate titanate (PZT) and a polyimide substrate, was developed for a muscle activity sensing demonstration. The fabricated PZT-5A elements were arranged into a 4 × 4 array and then packaged in polydimethylsiloxane (PDMS). In vitro porcine tissue experiments were carried out by generating the muscle activities artificially, and the muscle movements were detected by the proposed wearable US transducer via muscle movement imaging. Experimental results showed that all 16 elements had very similar acoustic behaviors: the averaged central frequency, −6 dB bandwidth, and electrical impedance in water were 10.59 MHz, 37.69%, and 78.41 Ω, respectively. The in vitro study successfully demonstrated the capability of monitoring local muscle activity using the prototyped wearable transducer. The findings indicate that ultrasonic sensing may be an alternative to standardize myoelectric control for assistive robotics applications. 
    more » « less
  4. Intent recognition in lower-limb assistive devices typically relies on neuromechanical sensing of an affected limb acquired through embedded device sensors. It remains unknown whether signals from more widespread sources such as the contralateral leg and torso positively influence intent recognition, and how specific locomotor tasks that place high demands on the neuromuscular system, such as changes of direction, contribute to intent recognition. In this study, we evaluated the performances of signals from varying mechanical modalities (accelerographic, gyroscopic, and joint angles) and locations (the trailing leg, leading leg and torso) during straight walking, changes of direction (cuts), and cuts to stair ascent with varying task anticipation. Biomechanical information from the torso demonstrated poor performance across all conditions. Unilateral (the trailing or leading leg) joint angle data provided the highest accuracy. Surprisingly, neither the fusion of unilateral and torso data nor the combination of multiple signal modalities improved recognition. For these fused modality data, similar trends but with diminished accuracy rates were reported during unanticipated conditions. Finally, for datasets that achieved a relatively accurate (≥90%) recognition of unanticipated tasks, these levels of recognition were achieved after the mid-swing of the trailing/transitioning leg, prior to a subsequent heel strike. These findings suggest that mechanical sensing of the legs and torso for the recognition of straight-line and transient locomotion can be implemented in a relatively flexible manner (i.e., signal modality, and from the leading or trailing legs) and, importantly, suggest that more widespread sensing is not always optimal. 
    more » « less
  5. Objective Intent recognition in lower-extremity assistive devices (e.g., prostheses and exoskeletons) is typically limited to either recognition of steady-state locomotion or changes of terrain (e.g., level ground to stair) occurring in a straight-line path and under anticipated condition. Stability is highly affected during non-steady changes of direction such as cuts especially when they are unanticipated, posing high risk of fall-related injuries. Here, we studied the influence of changes of direction and user anticipation on task recognition, and accordingly introduced classification schemes accommodating such effects. Methods A linear discriminant analysis (LDA) classifier continuously classified straight-line walking, sidestep/crossover cuts (single transitions), and cuts-to-stair locomotion (mixed transitions) performed under varied task anticipatory conditions. Training paradigms with varying levels of anticipated/unanticipated exposures and analysis windows of size 100–600 ms were examined. Results More accurate classification of anticipated relative to unanticipated tasks was observed. Including bouts of target task in the training data was necessary to improve generalization to unanticipated locomotion. Only up to two bouts of target task were sufficient to reduce errors to <20% in unanticipated mixed transitions, whereas, in single transitions and straight walking, substantial unanticipated information (i.e., five bouts) was necessary to achieve similar outcomes. Window size modifications did not have a significant influence on classification performance. Conclusion Adjusting the training paradigm helps to achieve classification schemes capable of adapting to changes of direction and task anticipatory state. Significance The findings could provide insight into developing classification schemes that can adapt to changes of direction and user anticipation. They could inform intent recognition strategies for controlling lower-limb assistive to robustly handle “unknown” circumstances, and thus deliver increased level of reliability and safety. 
    more » « less