Title: Detection of Low Lithium Concentrations Using Laser-Induced Breakdown Spectroscopy (LIBS) in High-Pressure and High-Flow Conditions
This paper describes the effects of laser pulse rate and solution flow rate on the determination of lithium at high pressure for water and 2.5% sodium chloride solutions using laser-induced breakdown spectroscopy (LIBS). Preliminary studies were performed with 0–40 mg L −1 Li solutions, at ambient pressure and at 210 bar, and in static and flowing (6 mL · min −1 ) regimes, for a combination of four different measurement conditions. The sensitivity of calibration curves depended on the pressure and the flow rate, as well as the laser pulse rate. The sensitivity of the calibration curve increased about 10% and 18% when the pressure was changed from 1 to 210 bar for static and flowing conditions, respectively. However, an effect of flow rate at high pressure for both 2 and 10 Hz laser pulse rates was observed. At ambient pressure, the effect of flow rate was negligible, as the sensitivity of the calibration curve decreased around 2%, while at high pressure the sensitivity increased around 4% when measurements were performed in a flow regime. Therefore, it seems there is a synergistic effect between pressure and flow rate, as the sensitivity increases significantly when both changes are considered. When the pulse rate is changed from 2 to 10 Hz, the sensitivity increases 26–31%, depending on the pressure and flow conditions. For lithium detection limit studies, performed with a laser pulse energy of 2.5 mJ, repetition rate of 10 Hz, gate delay of 500 ns, gate width of 1000 ns, and 1000 accumulations, a value around 40 µg L −1 was achieved for Li solutions in pure water for all four measurement conditions, while a detection limit of about 92 µg L −1 was determined for Li in 2.5% sodium chloride solutions, when high pressure and flowing conditions were employed. The results obtained in the present work demonstrate that LIBS is a powerful tool for the determination of Li in deep ocean conditions such as those found around hydrothermal vent systems.  more » « less
Award ID(s):
1829327
PAR ID:
10309593
Author(s) / Creator(s):
; ;
Date Published:
Journal Name:
Applied Spectroscopy
Volume:
75
Issue:
11
ISSN:
0003-7028
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. A dual color, frequency and pulse duration agile laser system, capable of delivering laser pulses in arbitrary temporal profiles with ∼1 ns to ∼1 µs pulse duration, chirping rates of ∼27 MHz/ns with an achievable chirping range of several GHz across the pulse duration, and with energies ranging from a few nJ to hundreds of mJ per pulse has been developed. The flexibility and capability of this laser system provide a wide range of laser parameters that can be exploited to optimize operational conditions in various experiments ranging from laser diagnostics to spectroscopy and optical manipulation of matter. The developed system is successfully demonstrated to obtain coherent Rayleigh-Brillouin scattering (CRBS) in both single and dual color configuration, in an effort to expand the non-intrusive accessibility towards lower pressure regime for neutral gas and plasma diagnostics. 
    more » « less
  2. Abstract This study delves into the dynamics of cold atmospheric plasma and their interaction within conductive solutions under the unique conditions of nanosecond pulsed discharges (22 kV peak voltage, 10 ns FWHM, 4.5 kV ns−1rate-of-rise). The research focuses on the electrical response, breakdown, and discharge propagation in an argon bubble, submerged in a NaCl solution of varying conductivity. Full or partial discharges were observed at conductivities of 1.5µS cm−1(deionized water) to 1.6 mS cm−1, but no breakdown was observed at 11.0 mS cm−1when reducing the electrode gap. It is demonstrated that at higher conductivity electric breakdown is observed only when the gas bubble comes into direct contact with the electrode and multiple emission nodes were observed at different timescales. These nodes expanded in the central region of the bubble over timescales longer than the initial high-voltage pulse. This work offers a temporal resolution of 2 ns exposure times over the first 30 ns of the initial voltage pulse, and insight into plasma formation over decaying reflected voltage oscillations over 200 ns. 
    more » « less
  3. null (Ed.)
    Optomechanical accelerometers promise quantum-limited readout, high bandwidth, self-calibration, and radiation-pressure stabilization. We present a simple, scalable platform that enables these benefits with sub-µg sensitivity and 10 kHz bandwidth, based on a pair of vertically integrated SiN membranes. 
    more » « less
  4. Abstract A continuous gas–liquid flowing film reactor with a nanosecond‐pulsed power supply was utilized for the degradation of perfluorooctanoic acid (PFOA) as assessed by fluoride (F) formation. PFOA, 50 mg/L, dissolved in deionized water was supplied at 2 ml/min with an argon carrier gas. The liquid phase was analyzed for Fusing ion chromatography. The power supply pulse frequency (f) was varied between 0.25‐ and 10‐kHz using a constant 16‐kV input voltage and 40‐ns pulse width. The highest Fproduction rate (), 1.57 × 10−8 mol/s, occurred at 5 kHz whereas the highest efficiency of Fproduction (), 9.12 × 10−9 mol/J, was found at 0.25 kHz. 
    more » « less
  5. Experiments accessing extreme conditions at x-ray free electron lasers (XFELs) involve rapidly evolving conditions of temperature. Here, we report time-resolved, direct measurements of temperature using spectral streaked optical pyrometry of x-ray and optical laser-heated states at the High Energy Density instrument of the European XFEL. This collection of typical experiments, coupled with numerical models, outlines the reliability, precision, and meaning of time dependent temperature measurements using optical emission at XFEL sources. Dynamic temperatures above 1500 K are measured continuously from spectrally- and temporally-resolved thermal emission at 450–850 nm, with time resolution down to 10–100 ns for 1–200 μs streak camera windows, using single shot and integrated modes. Targets include zero-pressure foils free-standing in air and in vacuo, and high-pressure samples compressed in diamond anvil cell multi-layer targets. Radiation sources used are 20-fs hard x-ray laser pulses at 17.8 keV, in single pulses or 2.26 MHz pulse trains of up to 30 pulses, and 250-ns infrared laser single pulses. A range of further possibilities for optical measurements of visible light in x-ray laser experiments using streak optical spectroscopy are also explored, including for the study of x-ray induced optical fluorescence, which often appears as background in thermal radiation measurements. We establish several scenarios where combined emissions from multiple sources are observed and discuss their interpretation. Challenges posed by using x-ray lasers as non-invasive probes of the sample state are addressed. 
    more » « less