skip to main content


Title: PV-EV Integrated Home Energy Management Considering Residential Occupant Behaviors
Rooftop photovoltaics (PV) and electrical vehicles (EV) have become more economically viable to residential customers. Most existing home energy management systems (HEMS) only focus on the residential occupants’ thermal comfort in terms of indoor temperature and humidity while neglecting their other behaviors or concerns. This paper aims to integrate residential PV and EVs into the HEMS in an occupant-centric manner while taking into account the occupants’ thermal comfort, clothing behaviors, and concerns on the state-of-charge (SOC) of EVs. A stochastic adaptive dynamic programming (ADP) model was proposed to optimally determine the setpoints of heating, ventilation, air conditioning (HVAC), occupant’s clothing decisions, and the EV’s charge/discharge schedule while considering uncertainties in the outside temperature, PV generation, and EV’s arrival SOC. The nonlinear and nonconvex thermal comfort model, EV SOC concern model, and clothing behavior model were holistically embedded in the ADP-HEMS model. A model predictive control framework was further proposed to simulate a residential house under the time of use tariff, such that it continually updates with optimal appliance schedules decisions passed to the house model. Cosimulations were carried out to compare the proposed HEMS with a baseline model that represents the current operational practice. The result shows that the proposed HEMS can reduce the energy cost by 68.5% while retaining the most comfortable thermal level and negligible EV SOC concerns considering the occupant’s behaviors.  more » « less
Award ID(s):
1856084
NSF-PAR ID:
10322357
Author(s) / Creator(s):
; ;
Date Published:
Journal Name:
Sustainability
Volume:
13
Issue:
24
ISSN:
2071-1050
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. This paper proposes a home energy management system (HEMS) while considering the residential occupant’s clothing integrated thermal comfort and electrical vehicles (EV) state-of-charge (SOC) concern. An adaptive dynamic program- ming (ADP) based HEMS model is proposed to optimally determine the setpoints of heating, ventilation, air conditioning (HVAC), the donning/doffing decisions for the clothing conditions and charging/discharging of EV while taking into account the uncertainties in outside temperature and EV arrival SOC. We use model predictive control (MPC) to simulate a multi-day energy management of a residential house equipped with the proposed HEMS. The proposed HEMS is compared with a baseline case without the HEMS. The simulation results show that a 47.5% of energy cost saving can be achieved by the proposed HEMS while maintaining satisfactory occupant thermal comfort and negligible EV SOC concerns. 
    more » « less
  2. Understanding occupants’ thermal sensation and comfort is essential to defining the operational settings for Heating, Ventilation and Air Conditioning (HVAC) systems in buildings. Due to the continuous impact of human and environmental factors, occupants’ thermal sensation and comfort level can change over time. Thus, to dynamically control the environment, thermal comfort should be monitored in real time. This paper presents a novel non-intrusive infrared thermography framework to estimate an occupant’s thermal comfort level by measuring skin temperature collected from different facial regions using low- cost thermal cameras. Unlike existing methods that rely on placing sensors directly on humans for skin temperature measurement, the proposed framework is able to detect the presence of occupants, extract facial regions, measure skin temperature features, and interpret thermal comfort conditions with minimal interruption of the building occupants. The method is validated by collecting thermal comfort data from a total of twelve subjects under cooling, heating and steady-state experiments. The results demonstrate that ears, nose and cheeks are most indicative of thermal comfort and the proposed framework can be used to assess occupants’ thermal comfort with an average accuracy of 85%. 
    more » « less
  3. Thermal comfort and energy efficiency are always the two most significant objectives in HVAC operations. However, for conventional HVAC systems, the pursuit of high energy efficiency may be at the expense of satisfactory thermal comfort. Therefore, even if centralized HVAC systems nowadays have higher energy efficiency than before in office buildings, most of them cannot adapt the dynamic occupant behaviors or individual thermal comfort. In order to realize high energy efficiency while still maintain satisfactory thermal environment for occupants indoors, the integrated hybrid HVAC system has been developed for years such as task-ambient conditioning system. Moreover, the occupant-based HVAC control system such as human- in-the-loop has also been investigated so that the system can be adaptive based on occupant behaviors. However, most of research related to personalized air-conditioning system only focuses on field-study with limited scale (i.e. only one office room), this paper has proposed a co- simulation model in energyplus to simulate the hybrid cooling system with synthetic thermal comfort distributions based on global comfort database I&II. An optimization framework on cooling set-point is proposed with the objective of energy performance and the constraints of thermal comfort distribution developed by unsupervised Gaussian mixture model (GMM) clustering and kernel density estimation (KDE). The co-simulation results have illustrated that with the proposed optimization algorithm and the hybrid cooling system, HVAC demand power has decreased 5.3% on average with at least 90% of occupants feeling satisfied. 
    more » « less
  4. About 40% of the energy produced globally is consumed within buildings, primarily for providing occupants with comfortable work and living spaces. However, despite the significant impacts of such energy consumption on the environment, the lack of thermal comfort among occupants is a common problem that can lead to health complications and reduced productivity. To address this problem, it is particularly important to understand occupants’ thermal comfort in real-time to dynamically control the environment. This study investigates an infrared thermal camera network to extract skin temperature features and predict occupants’ thermal preferences at flexible distances and angles. This study distinguishes from existing methods in two ways: (1) the proposed method is a non-intrusive data collection approach which does not require human participation or personal devices; (2) it uses low-cost thermal cameras and RGB-D sensors which can be rapidly reconfigured to adapt to various settings and has little or no hardware infrastructure dependency. The proposed camera network is verified using the facial skin temperature collected from 16 subjects in a multi-occupancy experiment. The results show that all 16 subjects observed a statistically higher skin temperature as the room temperature increases. The variations in skin temperature also correspond to the distinct comfort states reported by the subjects. The post-experiment evaluation suggests that the networked thermal cameras have a minimal interruption of building occupants. The proposed approach demonstrates the potential to transition the human physiological data collection from an intrusive and wearable device-based approach to a truly non-intrusive and scalable approach. 
    more » « less
  5. The objective of this study is to assess the effectiveness of wearable cooling in improving thermal comfort for a warm environment that would become prevalent due to more frequent extreme weather events, especially when air conditioning is not accessible for many developing countries. The experiment was conducted in an environment room with air temperature maintained at 31 °C and relative humidity at 55%. The study tested 30 participants using a wearable cooling device at the upper back location, while another 30 had no local cooling as the control group. Participants’ thermal comfort, thermal sensation and other metrics were assessed three times for a test session. The clothing insulation was 0.36 clo to simulate summer attire. The results showed significantly lower average local and whole-body thermal sensation for the participants with the wearable cooling device than the control group by considering all the votes during the entire session. Compared to the baseline, in particular, the local cooling group indicated a significant reduction in local thermal sensation for all three times of self-evaluation. Nevertheless, the reduction in overall thermal sensation occurred right after the local cooling was applied. Such a significant reduction was not observed after a while and then emerged again during the test, indicating an interactive phenomenon involving thermal adaptation and comfort restoration which will be investigated in the future. 
    more » « less