Title: Iron( iii ) chelated paramagnetic polymeric nanoparticle formulation as a next-generation T 1 -weighted MRI contrast agent
Magnetic resonance imaging (MRI) is a routinely used imaging technique in medical diagnostics. To enhance the quality of MR images, contrast agents (CAs) are used, which account for nearly 40% of MRI exams in the clinic globally. The most used CAs are gadolinium-based CAs (GBCAs) but the use of GBCAs has been linked with metal-deposition in vital organs. Gadolinium deposition has been shown to be correlated with nephrogenic systemic fibrosis, a fibrosis of the skin and internal organs. Therefore, there is an unmet need for a new CA alternative to GBCAs for T 1 -weighted Ce-MRI. Herein, we designed paramagnetic ferric iron( iii ) ion-chelated poly(lactic- co -glycolic)acid nanoparticle formulation and routinely examined their application in Ce-MRI using clinical and ultra-high-field MRI scanners. Nanoparticles were monodispersed and highly stable at physiological pH over time with the hydrodynamic size of 130 ± 12 nm and polydispersity index of 0.231 ± 0.026. The T 1 -contrast efficacy of the nanoparticles was compared with commercial agent gadopentetate dimeglumine, called Magnevist®, in aqueous phantoms in vitro and then validated in vivo by visualizing an angiographic map in a clinical MRI scanner. Relaxivities of the nanoparticles in an aqueous environment were r 1 = 10.59 ± 0.32 mmol −1 s −1 and r 1 = 3.02 ± 0.14 mmol −1 s −1 at 3.0 T and 14.1 T measured at room temperature and pH 7.4, respectively. The clinically relevant magnetic field relaxivity is three times higher compared to the Magnevist®, a clinical GBCA, signifying its potential applicability in clinical settings. Moreover, iron is an endogenous metal with known metabolic safety, and the polymer and phospholipids used in the nanoconstruct are biodegradable and biocompatible components. These properties further put the proposed T 1 agent in a promising position in contrast-enhanced MRI of patients with any disease conditions.  more » « less
Award ID(s):
1852182
PAR ID:
10322371
Author(s) / Creator(s):
; ; ;
Date Published:
Journal Name:
RSC Advances
Volume:
11
Issue:
51
ISSN:
2046-2069
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract

    The leitmotifs of magnetic resonance imaging (MRI) contrast agent-induced complications range from acute kidney injury, symptoms associated with gadolinium exposure (SAGE)/gadolinium deposition disease, potentially fatal gadolinium encephalopathy, and irreversible systemic fibrosis. Gadolinium is the active ingredient of these contrast agents, a non-physiologic lanthanide metal. The mechanisms of MRI contrast agent-induced diseases are unknown. Mice were treated with a MRI contrast agent. Human kidney tissues from contrast-naïve and MRI contrast agent-treated patients were obtained and analyzed. Kidneys (human and mouse) were assessed with transmission electron microscopy and scanning transmission electron microscopy with X-ray energy-dispersive spectroscopy. MRI contrast agent treatment resulted in unilamellar vesicles and mitochondriopathy in renal epithelium. Electron-dense intracellular precipitates and the outer rim of lipid droplets were rich in gadolinium and phosphorus. We conclude that MRI contrast agents are not physiologically inert. The long-term safety of these synthetic metal–ligand complexes, especially with repeated use, should be studied further.

     
    more » « less
  2. Abstract

    We have investigated the efficacy of superparamagnetic iron oxide nanoparticles (SPIONs) as positive T1contrast agents for low-field magnetic resonance imaging (MRI) at 64 millitesla (mT). Iron oxide-based agents, such as the FDA-approved ferumoxytol, were measured using a variety of techniques to evaluate T1contrast at 64 mT. Additionally, we characterized monodispersed carboxylic acid-coated SPIONs with a range of diameters (4.9–15.7 nm) in order to understand size-dependent properties of T1contrast at low-field. MRI contrast properties were measured using 64 mT MRI, magnetometry, and nuclear magnetic resonance dispersion (NMRD). We also measured MRI contrast at 3 T to provide comparison to a standard clinical field strength. SPIONs have the capacity to perform well as T1contrast agents at 64 mT, with measured longitudinal relaxivity (r1) values of up to 67 L mmol−1 s−1, more than an order of magnitude higher than corresponding r1values at 3 T. The particles exhibit size-dependent longitudinal relaxivities and outperform a commercial Gd-based agent (gadobenate dimeglumine) by more than eight-fold at physiological temperatures. Additionally, we characterize the ratio of transverse to longitudinal relaxivity, r2/r1and find that it is ~ 1 for the SPION based agents at 64 mT, indicating a favorable balance of relaxivities for T1-weighted contrast imaging. We also correlate the magnetic and structural properties of the particles with models of nanoparticle relaxivity to understand generation of T1contrast. These experiments show that SPIONs, at low fields being targeted for point-of-care low-field MRI systems, have a unique combination of magnetic and structural properties that produce large T1relaxivities.

     
    more » « less
  3. Magnetic nanoparticles are robust contrast agents for MRI and often produce particularly strong signal changes per particle. Leveraging these effects to probe cellular- and molecular-level phenomena in tissue can, however, be hindered by the large sizes of typical nanoparticle contrast agents. To address this limitation, we introduce single-nanometer iron oxide (SNIO) particles that exhibit superparamagnetic properties in conjunction with hydrodynamic diameters comparable to small, highly diffusible imaging agents. These particles efficiently brighten the signal in T 1 -weighted MRI, producing per-molecule longitudinal relaxation enhancements over 10 times greater than conventional gadolinium-based contrast agents. We show that SNIOs permeate biological tissue effectively following injection into brain parenchyma or cerebrospinal fluid. We also demonstrate that SNIOs readily enter the brain following ultrasound-induced blood–brain barrier disruption, emulating the performance of a gadolinium agent and providing a basis for future biomedical applications. These results thus demonstrate a platform for MRI probe development that combines advantages of small-molecule imaging agents with the potency of nanoscale materials. 
    more » « less
  4. Abstract

    Although imaging‐guided drug delivery represents a noninvasive alternative to both surgical resection and systemic methods, it has seen limited clinical use due to the potential toxicity and fast clearance of currently available imaging agents. Herein, we introduce theranostic biocompatible microcapsules as efficient contrast‐enhanced imaging agents that combine magnetic resonance imaging (MRI) with ultrasound‐triggered drug release for real‐time tracking and targeted delivery in vivo. The 3‐μm diameter capsules are assembled via layer‐by‐layer deposition of the natural polyphenol tannic acid and poly(N‐vinylpyrrolidone) with 4 nm iron oxide nanoparticles incorporated in the capsule wall. The nanoparticle‐modified capsules exhibit excellent T1and T2MRI contrast in a clinical 3T MRI scanner. Loaded with the anticancer drug doxorubicin, these capsules circulate in the blood stream for at least 48 h, which is a remarkable improvement compared to nonencapsulated nanoparticles. The application of focused ultrasound results in targeted drug release with a 16‐fold increase in doxorubicin localization in tumors compared to off‐target organs in a mouse model of breast cancer. Owing to the active contrast, long circulation, customizable size, shape, composition, and precise delivery of high payload concentrations, these materials present a powerful and safe platform for imaging‐guided precision drug delivery.

     
    more » « less
  5. Abstract

    Gd chelates have occupied most of the market of magnetic resonance imaging (MRI) contrast agents for decades. However, there have been some problems (nephrotoxicity, non‐specificity, and lowr1) that limit their applications. Herein, a wet‐chemical method is proposed for facile synthesis of poly(acrylic acid) (PAA) stabilized exceedingly small gadolinium oxide nanoparticles (ES‐GON‐PAA) with an excellent water dispersibility and a size smaller than 2.0 nm, which is a powerfulT1‐weighted MRI contrast agent for diagnosis of diseases due to its remarkable relaxivities (r1= 70.2 ± 1.8 mM−1s−1, andr2/r1= 1.02 ± 0.03, at 1.5 T). Ther1is much higher and ther2/r1is lower than that of the commercial Gd chelates and reported gadolinium oxide nanoparticles (GONs). Further ES‐GON‐PAA is developed with conjugation of RGD2 (RGD dimer) (i.e., ES‐GON‐PAA@RGD2) forT1‐weighted MRI of tumors that overexpress RGD receptors (i.e., integrinαvβ3). The maximum signal enhancement (ΔSNR) forT1‐weighted MRI of tumors reaches up to 372 ± 56% at 2 h post‐injection of ES‐GON‐PAA@RGD2, which is much higher than commercial Gd‐chelates (<80%). Due to the high biocompatibility and high tumor accumulation, ES‐GON‐PAA@RGD2 with remarkable relaxivities is a promising and powerfulT1‐weighted MRI contrast agent.

     
    more » « less