Title: Muscle as a tunable material: implications for achieving muscle-like function in robotic prosthetic devices
ABSTRACT An ideal prosthesis should perform as well as or better than the missing limb it was designed to replace. Although this ideal is currently unattainable, recent advances in design have significantly improved the function of prosthetic devices. For the lower extremity, both passive prostheses (which provide no added power) and active prostheses (which add propulsive power) aim to emulate the dynamic function of the ankle joint, whose adaptive, time-varying resistance to applied forces is essential for walking and running. Passive prostheses fail to normalize energetics because they lack variable ankle impedance that is actively controlled within each gait cycle. By contrast, robotic prostheses can normalize energetics for some users under some conditions. However, the problem of adaptive and versatile control remains a significant issue. Current prosthesis-control algorithms fail to adapt to changes in gait required for walking on level ground at different speeds or on ramps and stairs. A new paradigm of ‘muscle as a tunable material’ versus ‘muscle as a motor’ offers insights into the adaptability and versatility of biological muscles, which may provide inspiration for prosthesis design and control. In this new paradigm, neural activation tunes muscle stiffness and damping, adapting the response to applied forces rather than instructing the timing and amplitude of muscle force. A mechanistic understanding of muscle function is incomplete and would benefit from collaboration between biologists and engineers. An improved understanding of the adaptability of muscle may yield better models as well as inspiration for developing prostheses that equal or surpass the functional capabilities of biological limbs across a wide range of conditions.  more » « less
Award ID(s):
2016054
PAR ID:
10334284
Author(s) / Creator(s):
;
Date Published:
Journal Name:
Journal of Experimental Biology
Volume:
224
Issue:
19
ISSN:
0022-0949
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. The gait patterns of stroke survivors become slow and metabolically inefficient as a result of muscle weakness and low weight-bearing capacity. Exoskeletons and assistive robots can improve gait kinematics and energetics. However, the use of these powered devices may cause a reliance on the device itself that results in limited lasting improvement of the paretic leg function. Specifically, there exists a need to strengthen and train the response of weak ankle muscles, such as the soleus muscle, in stroke survivors. Impaired activation of the soleus muscle induces unnatural gait kinematics and reduced propulsion. The mechanical modulation of the soleus muscle can improve its loading response and enhance gait performance after a stroke. This paper develops a closed-loop feedback controller to manipulate the ankle joint dynamics to mechanically control the soleus muscle response using a motorized ankle orthosis. The control method is inspired by backstepping control techniques and developed to connect the ankle joint angular velocity and the soleus muscle response during the stance phase of walking. The tracking objective is quantified using an integral-like muscle error between the desired soleus response and the actual muscle response, which is measurable using surface electromyography (EMG). The closed-loop electric motor controller is designed to apply ankle perturbations exploiting the backstepping error and an adaptive control term to cope with uncertain parameters that satisfy the linear-in-the-parameters property. A switching signal is developed using heel and toe ground reaction forces to strategically perturb the ankle and target the soleus muscle loading response in real-time during the mid-late stance phase of walking. A Lyapunov-based stability analysis is used to guarantee a globally uniformly ultimately bounded (GUUB) tracking result. 
    more » « less
  2. null (Ed.)
    Transfemoral amputee gait often exhibits compensations due to the lack of ankle push-off power and control over swing foot position using passive prostheses. Powered prostheses can restore this functionality, but their effects on compensatory behaviors, specifically at the residual hip, are not well understood. This paper investigates residual hip compensations through walking experiments with three transfemoral amputees using a low-impedance powered knee-ankle prosthesis compared to their day-to-day passive prosthesis. The powered prosthesis used impedance control during stance for compliant interaction with the ground, a time-based push-off controller to deliver high torque and power, and phase-based trajectory tracking during swing to provide user control over foot placement. Experiments show that when subjects utilized the powered ankle push-off, less mechanical pull-off power was required from the residual hip to progress the limb forward. Overall positive work at the residual hip was reduced for 2 of 3 subjects, and negative work was reduced for all subjects. Moreover, all subjects displayed increased step length, increased propulsive impulses on the prosthetic side, and improved impulse symmetries. Hip circumduction improved for subjects who had previously exhibited this compensation on their passive prosthesis. These improvements in gait, especially reduced residual hip power and work, have the potential to reduce fatigue and overuse injuries in persons with transfemoral amputation. 
    more » « less
  3. Abstract Background After above-knee amputation, the missing biological knee and ankle are replaced with passive prosthetic devices. Passive prostheses are able to dissipate limited amounts of energy using resistive damper systems during “negative energy” tasks like sit-down. However, passive prosthetic knees are not able to provide high levels of resistance at the end of the sit-down movement when the knee is flexed, and users need the most support. Consequently, users are forced to over-compensate with their upper body, residual hip, and intact leg, and/or sit down with a ballistic and uncontrolled movement. Powered prostheses have the potential to solve this problem. Powered prosthetic joints are controlled by motors, which can produce higher levels of resistance at a larger range of joint positions than passive damper systems. Therefore, powered prostheses have the potential to make sitting down more controlled and less difficult for above-knee amputees, improving their functional mobility. Methods Ten individuals with above-knee amputations sat down using their prescribed passive prosthesis and a research powered knee-ankle prosthesis. Subjects performed three sit-downs with each prosthesis while we recorded joint angles, forces, and muscle activity from the intact quadricep muscle. Our main outcome measures were weight-bearing symmetry and muscle effort of the intact quadricep muscle. We performed paired t-tests on these outcome measures to test for significant differences between passive and powered prostheses. Results We found that the average weight-bearing symmetry improved by 42.1% when subjects sat down with the powered prosthesis compared to their passive prostheses. This difference was significant (p = 0.0012), and every subject’s weight-bearing symmetry improved when using the powered prosthesis. Although the intact quadricep muscle contraction differed in shape, neither the integral nor the peak of the signal was significantly different between conditions (integral p > 0.01, peak p > 0.01). Conclusions In this study, we found that a powered knee-ankle prosthesis significantly improved weight-bearing symmetry during sit-down compared to passive prostheses. However, we did not observe a corresponding decrease in intact-limb muscle effort. These results indicate that powered prosthetic devices have the potential to improve balance during sit-down for individuals with above-knee amputation and provide insight for future development of powered prosthetics. 
    more » « less
  4. Robotic knee-ankle prostheses have often fallen short relative to passive microprocessor prostheses in time-based clinical outcome tests. User ambulation endurance is an alternative clinical outcome metric that may better highlight the benefits of robotic prostheses. However, previous studies were unable to show endurance benefits due to inaccurate high-level classification, discretized mid-level control, and insufficiently difficult ambulation tasks. In this case study, we present a phase-based mid-level prosthesis controller which yields biomimetic joint kinematics and kinetics that adjust to suit a continuum of tasks. We enrolled an individual with an above-knee amputation and challenged him to perform repeated, rapid laps of a circuit comprising activities of daily living with both his passive prosthesis and a robotic prosthesis. The participant demonstrated improved endurance with the robotic prosthesis and our mid-level controller compared to his passive prosthesis, completing over twice as many total laps before fatigue and muscle discomfort required him to stop. We also show that time-based outcome metrics fail to capture this endurance improvement, suggesting that alternative metrics related to endurance and fatigue may better highlight the clinical benefits of robotic prostheses. 
    more » « less
  5. Current lower-limb prostheses do not provide active assistance in postural control tasks to maintain the user’s balance, particularly in situations of perturbation. In this study, we aimed to address this missing function by enabling neural control of robotic lower-limb prostheses. Specifically, electromyographic (EMG) signals (amplified neural control signals) recorded from antagonistic residual ankle muscles were used to drive a robotic prosthetic ankle directly and continuously. Participants with transtibial amputation were recruited and trained in using the EMG-driven robotic ankle. We studied how using the EMG-controlled ankle affected the participants’ anticipatory and compensatory postural control strategies and stability under expected perturbations compared with using their daily passive devices. We investigated the similarity of neuromuscular coordination (by analyzing motor modules) of the participants, using either device in a postural sway task, to that of able-bodied controls. Results showed that, compared with their passive prosthesis, the EMG-controlled prosthesis enabled participants to use near-normative postural control strategies, as evidenced by improved between-limb symmetry in intact-prosthetic center-of-pressure and joint angle excursions. Participants substantially improved postural stability, as evidenced by a reduction in steps or falls using the EMG-controlled prosthetic ankle. Furthermore, after relearning to use residual ankle muscles to drive the robotic ankle in postural control, nearly all participants’ motor module structure shifted toward that observed in individuals without limb amputations. Here, we have demonstrated the potential benefit of direct EMG control of robotic lower limb prostheses to restore normative postural control strategies (both neural and biomechanical) toward enhancing standing postural stability in amputee users. 
    more » « less