Abstract An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied depending on the size of phonon NTD-Ge sensors glued to both LMO and Ge absorbers, shape of the Ge light detectors (circular vs. square, from two suppliers), in different light collection conditions (with and without reflector, with aluminum coated LMO crystal surface). The scintillating bolometer array was operated over 8 months in the low-background conditions that allowed to probe a very low, μBq/kg, level of the LMO crystals radioactive contamination by 228 Th and 226 Ra.
more »
« less
Identification of new isomers in $$^{228}$$Ac: impact on dark matter searches
Abstract We report the identification of metastable isomeric states of $$^{228}$$ 228 Ac at 6.28 keV, 6.67 keV and 20.19 keV, with lifetimes of an order of 100 ns. These states are produced by the $$\beta $$ β -decay of $$^{228}$$ 228 Ra, a component of the $$^{232}$$ 232 Th decay chain, with $$\beta $$ β Q-values of 39.52 keV, 39.13 keV and 25.61 keV, respectively. Due to the low Q-value of $$^{228}$$ 228 Ra as well as the relative abundance of $$^{232}$$ 232 Th and their progeny in low background experiments, these observations potentially impact the low-energy background modeling of dark matter search experiments.
more »
« less
- Award ID(s):
- 1913742
- PAR ID:
- 10335771
- Author(s) / Creator(s):
- ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; more »
- Date Published:
- Journal Name:
- The European Physical Journal C
- Volume:
- 81
- Issue:
- 8
- ISSN:
- 1434-6044
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Abstract Ultra-pure NaI(Tl) crystals are the key element for a model-independent verification of the long standing DAMA result and a powerful means to search for the annual modulation signature of dark matter interactions. The SABRE collaboration has been developing cutting-edge techniques for the reduction of intrinsic backgrounds over several years. In this paper we report the first characterization of a 3.4 kg crystal, named NaI-33, performed in an underground passive shielding setup at LNGS. NaI-33 has a record low $$^{39}$$ 39 K contamination of 4.3 ± 0.2 ppb as determined by mass spectrometry. We measured a light yield of 11.1 ± 0.2 photoelectrons/keV and an energy resolution of 13.2% (FWHM/E) at 59.5 keV. We evaluated the activities of $$^{226}$$ 226 Ra and $$^{228}$$ 228 Th inside the crystal to be $$5.9\pm 0.6~\upmu $$ 5.9 ± 0.6 μ Bq/kg and $$1.6\pm 0.3~\upmu $$ 1.6 ± 0.3 μ Bq/kg, respectively, which would indicate a contamination from $$^{238}$$ 238 U and $$^{232}$$ 232 Th at part-per-trillion level. We measured an activity of 0.51 ± 0.02 mBq/kg due to $$^{210}$$ 210 Pb out of equilibrium and a $$\alpha $$ α quenching factor of 0.63 ± 0.01 at 5304 keV. We illustrate the analyses techniques developed to reject electronic noise in the lower part of the energy spectrum. A cut-based strategy and a multivariate approach indicated a rate, attributed to the intrinsic radioactivity of the crystal, of $$\sim $$ ∼ 1 count/day/kg/keV in the [5–20] keV region.more » « less
-
Abstract The analysis of the time profile of electrical signals produced by energy depositions in germanium detectors allows discrimination of events with different topologies. This is especially relevant for experiments searching for the neutrinoless double beta decay of $$^{76}$$ 76 Ge to distinguish the sought-after signal from other background sources. The standard calibration procedures used to tune the selection criteria for double-beta decay events use a $$^{228}$$ 228 Th source, because it provides samples of signal-like events. These samples exhibit energy spatial distributions with subtle different topologies compared to neutrinoless double-beta decay events. In this work, we will characterize these topological differences and, with the support of a $$^{56}$$ 56 Co source, evaluate biases and precision of calibration techniques which use such event samples. Our results will be particularly relevant for future experiments in which a solid estimation of the efficiency is required.more » « less
-
Abstract In the search for a monochromatic peak as the signature of neutrinoless double beta decay an excellent energy resolution and an ultra-low background around the Q -value of the decay are essential. The LEGEND-200 experiment performs such a search with high-purity germanium detectors enriched in 76 Ge immersed in liquid argon. To determine and monitor the stability of the energy scale and resolution of the germanium diodes, custom-made, low-neutron emission 228 Th sources are regularly deployed in the vicinity of the crystals. Here we describe the production process of the 17 sources available for installation in the experiment, the measurements of their alpha- and gamma- activities, as well as the determination of the neutron emission rates with a low-background LiI(Eu) detector operated deep underground. With a flux of ( 4.27 ± 0.60 stat ± 0.92 syst ) × 10 -4 n / (kBq·s), approximately one order of magnitude below that of commercial sources, the neutron-induced background rate, mainly from the activation of 76 Ge, is negligible compared to other background sources in LEGEND-200.more » « less
-
Abstract Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0 $$\nu \beta \beta $$ ν β β ), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0 $$\nu \beta \beta $$ ν β β of $$^{136}$$ 136 Xe with projected half-life sensitivity of $$1.35\times 10^{28}$$ 1.35 × 10 28 yr. To reach this sensitivity, the design goal for nEXO is $$\le $$ ≤ 1% energy resolution at the decay Q -value ( $$2458.07\pm 0.31$$ 2458.07 ± 0.31 keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163 K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay Q -value for the nEXO design.more » « less
An official website of the United States government

