Title: Rheological characterization of poly-dimethyl siloxane formulations with tunable viscoelastic properties
Studies from the past two decades have demonstrated convincingly that cells are able to sense the mechanical properties of their surroundings. Cells make major decisions in response to this mechanosensation, including decisions regarding cell migration, proliferation, survival, and differentiation. The vast majority of these studies have focused on the cellular mechanoresponse to changing substrate stiffness (or elastic modulus) and have been conducted on purely elastic substrates. In contrast, most soft tissues in the human body exhibit viscoelastic behavior; that is, they generate responsive force proportional to both the magnitude and rate of strain. While several recent studies have demonstrated that viscous effects of an underlying substrate affect cellular mechanoresponse, there is not a straightforward experimental method to probe this, particularly for investigators with little background in biomaterial fabrication. In the current work, we demonstrate that polymers comprised of differing polydimethylsiloxane (PDMS) formulations can be generated that allow for control over both the strain-dependent storage modulus and the strain rate-dependent loss modulus. These substrates requires no background in biomaterial fabrication to fabricate, are shelf-stable, and exhibit repeatable mechanical properties. Here we demonstrate that these substrates are biocompatible and exhibit similar protein adsorption characteristics regardless of mechanical properties. Finally, we develop a set of empirical equations that predicts the storage and loss modulus for a given blend of PDMS formulations, allowing users to tailor substrate mechanical properties to their specific needs.  more » « less
Award ID(s):
2009748
NSF-PAR ID:
10341919
Author(s) / Creator(s):
; ; ; ; ;
Date Published:
Journal Name:
RSC Advances
Volume:
11
Issue:
57
ISSN:
2046-2069
Page Range / eLocation ID:
35910 to 35917
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. null (Ed.)
    In this paper, we report on a novel biocompatible micromechanical bioreactor (actuator and sensor) designed for the in situ manipulation and characterization of live microtissues. The purpose of this study was to develop and validate an application-targeted sterile bioreactor that is accessible, inexpensive, adjustable, and easily fabricated. Our method relies on a simple polydimethylsiloxane (PDMS) molding technique for fabrication and is compatible with commonly-used laboratory equipment and materials. Our unique design includes a flexible thin membrane that allows for the transfer of an external actuation into the PDMS beam-based actuator and sensor placed inside a conventional 35 mm cell culture Petri dish. Through computational analysis followed by experimental testing, we demonstrated its functionality, accuracy, sensitivity, and tunable operating range. Through time-course testing, the actuator delivered strains of over 20% to biodegradable electrospun poly (D, L-lactide-co-glycolide) (PLGA) 85:15 non-aligned nanofibers (~91 µm thick). At the same time, the sensor was able to characterize time-course changes in Young’s modulus (down to 10–150 kPa), induced by an application of isopropyl alcohol (IPA). Furthermore, the actuator delivered strains of up to 4% to PDMS monolayers (~30 µm thick), simultaneously characterizing their elastic modulus up to ~2.2 MPa. The platform repeatedly applied dynamic (0.23 Hz) tensile stimuli to live Human Dermal Fibroblast (HDF) cells for 12 hours (h) and recorded the cellular reorientation towards two angle regimes, with averages of −58.85° and +56.02°. The device biocompatibility with live cells was demonstrated for one week, with no signs of cytotoxicity. We can conclude that our PDMS bioreactor is advantageous for low-cost tissue/cell culture micromanipulation studies involving mechanical actuation and characterization. Our device eliminates the need for an expensive experimental setup for cell micromanipulation, increasing the ease of live-cell manipulation studies by providing an affordable way of conducting high-throughput experiments without the need to open the Petri dish, reducing manual handling, cross-contamination, supplies, and costs. The device design, material, and methods allow the user to define the operational range based on their targeted samples/application. 
    more » « less
  2. Abstract

    Utilization of self‐healing chemistry to develop synthetic polymer materials that can heal themselves with restored mechanical performance and functionality is of great interest. Self‐healable polymer elastomers with tunable mechanical properties are especially attractive for a variety of applications. Herein, a series of urea functionalized poly(dimethyl siloxane)‐based elastomers (U‐PDMS‐Es) are reported with extremely high stretchability, self‐healing mechanical properties, and recoverable gas‐separation performance. Tailoring the molecular weights of poly(dimethyl siloxane) or weight ratio of elastic cross‐linker offers tunable mechanical properties of the obtained U‐PDMS‐Es, such as ultimate elongation (from 984% to 5600%), Young's modulus, ultimate tensile strength, toughness, and elastic recovery. The U‐PDMS‐Es can serve as excellent acoustic and vibration damping materials over a broad range of temperature (over 100 °C). The strain‐dependent elastic recovery behavior of U‐PDMS‐Es is also studied. After mechanical damage, the U‐PDMS‐Es can be healed in 120 min at ambient temperature or in 20 min at 40 °C with completely restored mechanical performance. The U‐PDMS‐Es are also demonstrated to exhibit recoverable gas‐separation functionality with retained permeability/selectivity after being damaged.

     
    more » « less
  3. Living cells sense and respond to their extracellular environment. Their contact guidance is affected by the underlying substrate morphology. Previous studies of the effect of substrate pattern on the mechanical behavior of living cells were only limited to the quantification of the cellular elasticity. However, how the length and time scales of the cellular mechanical properties are affected by the patterned substrates have yet to be studied. In this study, the effect of the substrate morphology on the biomechanical behavior of living cells was thoroughly investigated using indentation-based atomic force microscopy. The results showed that the cellular biomechanical behavior was affected by the substrate morphology significantly. The elasticity and viscosity of the cells on the patterned PDMS substrates were much lower compared to those cultured on flat PDMS. The poroelastic diffusion coefficient of the cells was higher on the patterned PDMS substrates, specifically on the substrate with 2D pitches. In addition, fluorescence images showed that the substrate topography directly affects the cell cytoskeleton morphology. Together, the results suggested that cell mechanical behavior and morphology can be controlled using substrates with properly designed topography. 
    more » « less
  4. Atomic Force Microscopy (AFM) force-distance (FD) experiments have emerged as an attractive alternative to traditional micro-rheology measurement techniques owing to their versatility of use in materials of a wide range of mechanical properties. Here, we show that the range of time dependent behaviour which can reliably be resolved from the typical method of FD inversion (fitting constitutive FD relations to FD data) is inherently restricted by the experimental parameters: sampling frequency, experiment length, and strain rate. Specifically, we demonstrate that violating these restrictions can result in errors in the values of the parameters of the complex modulus. In the case of complex materials, such as cells, whose behaviour is not specifically understood a priori , the physical sensibility of these parameters cannot be assessed and may lead to falsely attributing a physical phenomenon to an artifact of the violation of these restrictions. We use arguments from information theory to understand the nature of these inconsistencies as well as devise limits on the range of mechanical parameters which can be reliably obtained from FD experiments. The results further demonstrate that the nature of these restrictions depends on the domain (time or frequency) used in the inversion process, with the time domain being far more restrictive than the frequency domain. Finally, we demonstrate how to use these restrictions to better design FD experiments to target specific timescales of a material's behaviour through our analysis of a polydimethylsiloxane (PDMS) polymer sample. 
    more » « less
  5. Abstract

    Energy harvesting (EH) technologies have been rapidly developed to replace the batteries of biomechanical electronics, but efforts are still needed to close the technology gaps in achieving flexible and biocompatible energy harvesters. Current flexible energy harvesters based on ZnO nanoarrays require complex fabrication processes, and they are non‐stretchable as they are usually fabricated on hard substrates. In this work, a facile approach is reported for fabricating a substrate‐free energy harvester with ZnO nanoarrays directly and fully embedded in a skin‐like polydimethylsiloxane (PDMS) elastomeric matrix that shares a similar mechanical property with that of human skin. The flexible device, with an elastic modulus of 3.3 MPa, can be stretched to 250% of its original length, generates an open‐circuit voltage up to 9.2 Vppand power LEDs from finger‐hand motions. Further, the device collects energy from hand‐finger motions and heartbeats through ex and in vivo tests. A ≈0.3 Vppopen circuit voltage is generated from the device installed on a leadless pacemaker in a porcine model. This work suggests a generic design strategy that overcomes the mechanical mismatch between the energy materials and soft tissues for a wide range of biomechanical EH applications from wearables to implantable ones.

     