Title: The Green’s Function-Based Thermal Analysis of a Spherical Geothermal Tank in a Semi-Infinite Domain
Abstract The Green’s function of a bimaterial infinite domain with a plane interface is applied to thermal analysis of a spherical underground heat storage tank. The heat transfer from a spherical source is derived from the integral of the Green’s function over the spherical domain. Because the thermal conductivity of the tank is generally different from soil, the Eshelby’s equivalent inclusion method (EIM) is used to simulate the thermal conductivity mismatch of the tank from the soil. For simplicity, the ground with an approximately uniform temperature on the surface is simulated by a bimaterial infinite domain, which is perfectly conductive above the ground. The heat conduction in the ground is investigated for two scenarios: First, a steady-state uniform heat flux from surface into the ground is considered, and the heat flux is disturbed by the existence of the tank due to the conductivity mismatch. A prescribed temperature gradient, or an eigen-temperature gradient, is introduced to investigate the local temperature field in the neighborhood of the tank. Second, when a temperature difference exists between the water in the tank and soil, the heat transfer between the tank and soil depends on the tank size, conductivity, and temperature difference, which provide a guideline for heat exchange design for the tank size. The modeling framework can be extended to two-dimensional cases, periodic, or transient heat transfer problems for geothermal well operations. The corresponding Green’s functions are provided for those applications.  more » « less
Award ID(s):
1738802 1941244 1762891
PAR ID:
10345515
Author(s) / Creator(s):
; ; ;
Date Published:
Journal Name:
Journal of Applied Mechanics
Volume:
89
Issue:
7
ISSN:
0021-8936
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. McCartney, J.S.; Tomac, I. (Ed.)
    Energy piles are one of the best candidates to harvest shallow geothermal energy. Continuing harvesting and rejecting thermal energy from/to the ground may permanently change the soil temperature and consequently, may lead to different soil resistance parameters. Therefore, careful prediction of soil temperature variation close to energy geostructures is needed. This paper investigates the various parameters of heat source and soil media on transient heat transport in unsaturated soils. Green’s function and the method of separation of variables are employed to analytically analyze the transient heat transfer in the vicinity of energy piles. Results indicate that although higher heat flux increases the soil temperature surrounding a heat source, it has negligible effect on thermal influence zone where the soil temperature varies. In contrast, higher thermal diffusivity results in lower soil temperature close to a heat source while it increases the thermal influence zone. 
    more » « less
  2. Abstract Improved modeling of permafrost active layer freeze‐thaw plays a crucial role in understanding the response of the Arctic ecosystem to the accelerating warming trend in the region over the past decades. However, modeling the dynamics of the active layer at diurnal time scale remains challenging using the traditional models of freeze‐thaw processes. In this study, a physically based analytical model is formulated to simulate the thaw depth of the active layer under changing boundary conditions of soil heat flux. Conservation of energy for the active layer leads to a nonlinear integral equation of the thaw depth using a temperature profile approximated from the analytical solution of the heat transfer equation forced by ground heat flux. Temporally variable ground heat flux is estimated using non‐gradient models when field observations are not available. Validation of the proposed model conducted against field data obtained from three Arctic forest and tundra sites demonstrates that the model is able to simulate both thaw depth and soil temperature profiles accurately. The model has the potential to estimate regional variability of the thaw depth for permafrost related applications. 
    more » « less
  3. The present investigation represents the rotational effect on gas turbine blade internal cooling with a uniform heat flux of 2000 W/m2 at the bottom wall. The experiment was conducted with three different rpms, such as 300 rpm, 600 rpm, and 900 rpm, with Reynolds number (Re) ranging from 6000 to 50,000 with a two-pass cooling channel. The numerical investigation was conducted with the large eddy simulation (LES) technique to understand the rotational flow behavior of the cooling channel. Four distinct arrangements of dimpled cooling channel surfaces were considered with two different dimple shapes, i.e., partial spherical and leaf. It is found that the rotation effect, dimple arrangement, and design have significant influences on heat transfer. Results indicated that the partial spherical 1-row dimpled surface experienced the highest heat transfer coefficient and pressure drop. In contrast, the leaf-shaped dimpled cooling channel experienced the highest thermal efficiency. 
    more » « less
  4. The exact heat transfer mechanism in the soil media can be understood by analyzing the soil behavior surrounding the heat sources. In literature, heat conduction has been considered as a main heat transfer mechanism in soil, and less attention has been given to the natural heat convection in saturated soils. There is only limited research in the literature which shows the presence of thermally induced pore fluid flow in soil media. It has been observed that heat convection through pore fluid flow in sand facilitates heat transfer in the ground. Therefore, both heat conduction and heat convection must be considered to accurately model the heat transfer mechanism in soil. In this paper, the presence of natural convection of water in a 2D axisymmetric domain of soil with a vertical heat source has been numerically investigated in steady-state condition. The soil thermal response and heat transfer mechanism for different soil types are compared. Feasibility of thermally-induced pore fluid flow is analyzed for different soil types. The results determine the presence of thermally driven pore fluid flow in high permeability soil (e.g., coarse sand) and confirm that the effect of heat convection in low permeability silt and clay is negligible. 
    more » « less
  5. The trapped residual magnetic flux during the cool-down due to the incomplete Meissner state is a significant source of radio frequency losses in superconducting radio frequency cavities. Here, we clearly correlate the niobium microstructure in elliptical cavity geometry and flux expulsion behavior. In particular, a traditionally fabricated Nb cavity half-cell from an annealed poly-crystalline Nb sheet after an 800 C heat treatment leads to a bi-modal microstructure that ties in with flux trapping and inefficient flux expulsion. This non-uniform microstructure is related to varying strain profiles along the cavity shape. A novel approach to prevent this non-uniform microstructure is presented by fabricating a 1.3 GHz single cell Nb cavity with a cold-worked sheet and subsequent heat treatment leading to better flux expulsion after 800 C/3 h. Microstructural evolution by electron backscattered diffraction-orientation imaging microscopy on cavity cutouts, and flux pinning behavior by dc-magnetization on coupon samples confirms a reduction in flux pinning centers with increased heat treatment temperature. The heat treatment temperature-dependent mechanical properties and thermal conductivity are reported. The significant impact of cold work in this study demonstrates clear evidence for the importance of the microstructure required for high-performance superconducting cavities with reduced losses caused by magnetic flux trapping. 
    more » « less