skip to main content


Title: Femtosecond ultraviolet laser absorption spectroscopy for simultaneous measurements of temperature and OH concentration
This Letter reports a femtosecond ultraviolet laser absorption spectroscopy (fs-UV-LAS) for simultaneous in situ measurements of temperature and species. This fs-UV-LAS technique was demonstrated based on X 2 Π-A 2 Σ + transitions of OH radicals near 308 nm generated in low temperature plasmas and flames. The fs-UV-LAS technique has revealed three major diagnostic benefits. First, a series of absorption features within a spectral bandwidth of ∼3.2 nm near 308 nm were simultaneously measured and then enabled simultaneous multi-parameter measurements with enhanced accuracy. The results show that the temperature and OH concentration could be measured with accuracy enhanced by 29–88% and 58–91%, respectively, compared to those obtained with past two-narrow-line absorption methods. Second, an ultrafast time resolution of ∼120 picoseconds was accomplished for the measurements. Third, due to the large OH X 2 Π-A 2 Σ + transitions in the UV range, a simple single-pass absorption with a 3-cm path length was allowed for measurements in plasmas with low OH number density down to ∼2 × 10 13  cm −3 . Also due to the large OH UV transitions, single-shot fs absorption measurements were accomplished in flames, which was expected to offer more insights into chemically reactive flow dynamics.  more » « less
Award ID(s):
1903362 2029425
NSF-PAR ID:
10347159
Author(s) / Creator(s):
; ; ; ; ;
Date Published:
Journal Name:
Applied Physics Letters
Volume:
120
Issue:
20
ISSN:
0003-6951
Page Range / eLocation ID:
201103
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. In many low-temperature plasmas (LTPs), the OH radical and temperature represent key properties of plasma reactivity. However, OH and temperature measurements in weakly ionized LTPs are challenging, due to the low concentration and short lifetime of OH and the abrupt temperature rise caused by fast gas heating. To address such issues, this Letter combined cavity-enhanced absorption spectroscopy (CEAS) with femtosecond (fs) pulses to enable sensitive single-shot broadband measurements of OH and temperature with a time resolution of ∼180 ns in LTPs. Such a combination leveraged several benefits. With the appropriately designed cavity, an absorption gain of ∼66 was achieved, enhancing the actual OH detection limit by ∼55× to the 1011cm-3level (sub-ppm in this work) compared with single-pass absorption. Single-shot measurements were enabled while maintaining a time resolution of ∼180 ns, sufficiently short for detecting OH with a lifetime of ∼100 μs. With the broadband fs laser, ∼34,000 cavity modes were matched with ∼95 modes matched on each CCD pixel bandwidth, such that fs-CEAS became immune to the laser-cavity coupling noise and highly robust across the entire spectral range. Also, the broadband fs laser allowed simultaneous sensing of many absorption features to enable simultaneous multi-parameter measurements with enhanced accuracies.

     
    more » « less
  2. This paper presents an extensive parameter study of a non-intrusive and non-seeded laser diagnostic method for measuring one dimensional (1D) rotational temperature of molecular nitrogen (N2) at 165 - 450 K. Compared to previous efforts using molecular oxygen, here resonantly ionized and photoelectron induced fluorescence of molecular nitrogen for thermometry (N2RIPT) was demonstrated. The RIPT signal is generated by directly probing various rotational levels within the rovibrational absorption band of N2, corresponding to the 3-photon transition of N2(X1Σg+,v=0→b1Πu,v=6) near 285 nm, without involving collisional effects of molecular oxygen and nitrogen. The photoionized N2produces strong first negative band of N2+(B2Σu+X2Σg+) near 390 nm, 420 nm, and 425 nm. Boltzmann analyses of various discrete fluorescence emission lines yield rotational temperatures of molecular nitrogen. By empirically choosing multiple rotational levels within the absorption band, non-scanning thermometry can be accurately achieved for molecular nitrogen. It is demonstrated that the N2RIPT technique can measure 1D temperature profile up to ∼5 cm in length within a pure N2environment. Multiple wavelengths are thoroughly analyzed and listed that are accurate for RIPT for various temperature ranges.

     
    more » « less
  3. Ultra-short optical pulses in the ultraviolet (UV) region are of significant interest for combustion and reacting flow diagnostics, as most important chemical species have electronic resonance transitions in the UV region. Optical parametric amplifiers are typically used for frequency conversion of femtosecond (fs) pulses from near-IR to UV; however, their implementation for practical imaging applications is limited because of the low conversion efficiency and extreme sensitivity to ambient conditions. In this work, we report the implementation of direct-frequency-tripled, fs laser pulses from a tunable amplified laser system for high-resolution imaging of hydroxyl (OH) radical in flames. The fundamental laser output near 850 nm is frequency tripled to obtain approximately 283.3-nm UV radiation. OH planar laser-induced fluorescence (PLIF) imaging at 1 kHz is demonstrated in turbulent flames with image sheet heights in excess of 45 mm and a signal-to-noise ratio better than 25. These results represent over3×<#comment/>increase in the imaging dimensionality compared to traditional OPA-based systems. Additionally, the third-harmonic generation apparatus is compact, robust, and easy to operate while providing near-Gaussian beam profiles. Simple power scaling suggests another factor of 3 or more increase in sheet height can be achieved for kilohertz-rate practical combustion diagnostics applications.

     
    more » « less
  4. Abstract

    We have analyzed medium‐resolution (full width at half maximum, FWHM = 1.2 nm), Middle UltraViolet (MUV; 180–280 nm) laboratory emission spectra of carbon monoxide (CO) excited by electron impact at 15, 20, 40, 50, and 100 eV under single‐scattering conditions at 300 K. The MUV emission spectra at 100 eV contain the Cameron Bands (CB) CO(a3Π → X1Σ+), the fourth positive group (4PG) CO(A1Π → X1Σ+), and the first negative group (1NG) CO+(B2Σ+→ X2Σ) from direct excitation and cascading‐induced emission of an optically thin CO gas. We have determined vibrational intensities and emission cross sections for these systems, important for modeling UV observations of the atmospheres of Mars and Venus. We have also measured the CB “glow” profile about the electron beam of the long‐lived CO (a3Π) state and determined its average metastable lifetime of 3 ± 1 ms. Optically allowed cascading from a host of triplet states has been found to be the dominant excitation process contributing to the CB emission cross section at 15 eV, most strongly by the d3Δ and a'3Σ+electronic states. We normalized the CB emission cross section at 15 eV electron impact energy by multilinear regression (MLR) analysis to the blended 15 eV MUV spectrum over the spectral range of 180–280 nm, based on the 4PG emission cross section at 15 eV that we have previously measured (Ajello et al., 2019,https://doi.org/10.1029/2018ja026308). We find the CB total emission cross section at 15 eV to be 7.7 × 10−17 cm2.

     
    more » « less
  5. An optical parametric oscillator (OPO) is developed and characterized for the simultaneous generation of ultraviolet (UV) and near-UV nanosecond laser pulses for the single-shot Rayleigh scattering and planar laser-induced-fluorescence (PLIF) imaging of methylidyne (CH) and nitric oxide (NO) in turbulent flames. The OPO is pumped by a multichannel, 8-pulse Nd:YAG laser cluster that produces up to 225 mJ/pulse at 355 nm with pulse spacing of 100 µs. The pulsed OPO has a conversion efficiency of 9.6% to the signal wavelength of∼<#comment/>430nmwhen pumped by the multimode laser. Second harmonic conversion of the signal, with 3.8% efficiency, is used for the electronic excitation of the A-X (1,0) band of NO at∼<#comment/>215nm, while the residual signal at 430 nm is used for direct excitation of the A-X (0,0) band of the CH radical and elastic Rayleigh scattering. The section of the OPO signal wavelength for simultaneous CH and NO PLIF imaging is performed with consideration of the pulse energy, interference from the reactant and product species, and the fluorescence signal intensity. The excitation wavelengths of 430.7 nm and 215.35 nm are studied in a laminar, premixedCH4−<#comment/>H2−<#comment/>NH3–air flame. Single-shot CH and NO PLIF and Rayleigh scatter imaging is demonstrated in a turbulentCH4−<#comment/>H2−<#comment/>NH3diffusion flame using a high-speed intensified CMOS camera. Analysis of the complementary Rayleigh scattering and CH and NO PLIF enables identification and quantification of the high-temperature flame layers, the combustion product zones, and the fuel-jet core. Considerations for extension to simultaneous, 10-kHz-rate acquisition are discussed.

     
    more » « less