Abstract. Polished geological samples are frequently used in geoscientific research to investigate the chemical and physical characteristics of rocks. A broad range of imaging techniques is available to analyze such samples, but when combining datasets from multiple imaging techniques, an accurate co-registration of the datasets is often challenging. In this study, we investigate this issue in the context of Micromagnetic Tomography (MMT; De Groot et al., 2018, 2021). MMT combines surface magnetometry data with computed tomography (CT) data to analyze the magnetic state of rock samples. By combining the spatial (position) and dimensional (size) information of the magnetic grains in the samples with their magnetic surface expression, the individual magnetic moments per grain can be determined. This information can be used for paleomagnetic and rock-magnetic studies. Calculating the magnetic moments of the grains strongly depends on the correct co-registration of the two datasets, which proves to be challenging. In this study, we used two test samples for the application of micro-sized marker structures, to further develop the methodology of MMT. The marker structures are applied by microlithography and Nb-sputter coating, which are standard techniques used in the semiconductor industry. We determined that the marker structure application is possible on typical MMT samples. Marker structures larger than ca. 10 µm are clearly visible under the Quantum Diamond Microscope (QDM) used for the surface magnetometry. Given a sufficient marker structure thickness, they can also be observed in the CT scans used for determining the positions and shapes of the magnetic carriers. The marker structures are useful for identifying the orientation and location of the samples during measurements and can be used for scaling and mapping of the two datasets during data processing. Nb-marker structures do not fluoresce under the QDM, which means that no magnetic interference occurs during measurements. The application procedure is time-consuming but is valuable when a sample is lacking natural marker features, it makes the data processing time in MMT significantly faster, and more precise. This method can be useful for MMT, for Quantum Diamond Microscopy in general, and for broader geological applications that require visible anchor points for sample placement or marker structures for the co-registration of multiple datasets.
more »
« less
High‐Sensitivity Moment Magnetometry With the Quantum Diamond Microscope
Abstract Interest in magnetic fields on the ancient Earth and other planetary bodies has motivated the paleomagnetic analysis of complex rocks such as meteorites that carry heterogeneous magnetizations at <<1 mm scales. The net magnetic moment of natural remanent magnetization (NRM) in such small samples is often below the detection threshold of common cryogenic magnetometers. The quantum diamond microscope (QDM) is an emerging magnetic imaging technology with ~1 μm resolution and can, in principle, recover magnetizations as weak as 10−17 Am2. However, the typically 1–100 μm sample‐to‐sensor distance of QDM measurements can result in complex (nondipolar) magnetic field maps, from which the net magnetic moment cannot be determined using a simple algorithm. Here we generate synthetic magnetic field maps to quantify the errors introduced by sample nondipolarity and by map processing procedures such as upward continuation. We find that inversions based on least squares dipole fits of upward continued data can recover the net moment of complex samples with <5% to 10% error for maps with signal‐to‐noise ratio (SNR) in the range typical of current generation QDMs. We validate these error estimates experimentally using comparisons between QDM maps and between QDM and SQUID microscope data, concluding that, within the limitations described here, the QDM is a robust technique for recovering the net magnetic moment of weakly magnetized samples. More sophisticated net moment fitting algorithms in the future can be combined with upward continuation methods described here to improve accuracy.
more »
« less
- PAR ID:
- 10374351
- Publisher / Repository:
- DOI PREFIX: 10.1029
- Date Published:
- Journal Name:
- Geochemistry, Geophysics, Geosystems
- Volume:
- 21
- Issue:
- 8
- ISSN:
- 1525-2027
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Abstract Recent advances in magnetic microscopy have enabled studies of geological samples whose weak and spatially nonuniform magnetizations were previously inaccessible to standard magnetometry techniques. A quantity of central importance is the net magnetic moment, which reflects the mean direction and the intensity of the magnetization states of numerous ferromagnetic crystals within a certain volume. The planar arrangement of typical magnetic microscopy measurements, which originates from measuring the field immediately above the polished surface of a sample to maximize sensitivity and spatial resolution, makes estimating net moments considerably more challenging than with spherically distributed data. In particular, spatially extended and nonuniform magnetization distributions often cannot be adequately approximated by a single magnetic dipole. To address this limitation, we developed a multipole fitting technique that can accurately estimate net moment using spherical harmonic multipole expansions computed from planar data. Given that the optimal location for the origin of such expansions is unknown beforehand and generally unconstrained, regularization of this inverse problem is critical for obtaining accurate moment estimates from noisy experimental magnetic data. We characterized the performance of the technique using synthetic sources under different conditions (noiseless data, data corrupted with simulated white noise, and data corrupted with measured instrument noise). We then validated and demonstrated the technique using superconducting quantum interference device microscopy measurements of impact melt spherules from Lonar crater, India and dusty olivine chondrules from the CO chondrite meteorite Dominion Range 08006.more » « less
-
Abstract Speleothems are mineral deposits capable of recording detrital and/or chemical remanent magnetization at annual timescales. They can offer high‐resolution paleomagnetic records of short‐term variations in Earth's magnetic field, crucial for understanding the evolution of the dynamo. Owing to limitations on the magnetic moment sensitivity of commercial cryogenic rock magnetometers (∼10−11 Am2), paleomagnetic studies of speleothems have been limited to samples with volumes of several hundreds of mm3, averaging tens to hundreds of years of magnetic variation. Nonetheless, smaller samples (∼1–10 mm3) can be measured using superconducting quantum interference device (SQUID) microscopy, with a sensitivity better than ∼10−15 Am2. To determine the application of SQUID microscopy for obtaining robust high‐resolution records from small‐volume speleothem samples, we analyzed three different stalagmites collected from Lapa dos Morcegos Cave (Portugal), Pau d'Alho Cave (Brazil), and Crevice Cave (United States). These stalagmites are representative of a range of magnetic properties and have been previously studied with conventional rock magnetometers. We show that by using SQUID microscopy we can achieve a five‐fold improvement in temporal resolution for samples with higher abundances of magnetic carriers (e.g., Pau d'Alho Cave and Lapa dos Morcegos Cave). In contrast, speleothems with low abundances of magnetic carriers (e.g., Crevice Cave) do not benefit from higher resolution analysis and are best analyzed using conventional rock magnetometers. Overall, by targeting speleothem samples with high concentrations of magnetic carriers we can increase the temporal resolution of magnetic records, setting the stage for resolving geomagnetic variations at short time scales.more » « less
-
Abstract We report two new organic green‐absorbing singlet oxygen (1O2) photosensitizers: Quinoidal naphthyl thioamide (QDM) andbis‐iodol‐dipyrrolonaphthyridine‐dione (I2–DPND), with triplet energies of 40.8 and 47.5 kcal mol−1(at 77 K in a glassy matrix) , respectively. The UV–vis absorption and emission characteristics ofQDMandI2–DPNDare similar to other commercially available organic1O2photosensitizers such as Rose Bengal, which was used as standard/reference to estimate the1O2quantum yield (Φ∆) of the chromophores under study. Using 9,10‐diphenylanthracene (DPA) as an1O2quencher, we estimated the Φ∆≈ 67–85% forQDMand Φ∆≈ 25–32% forI2–DPND. The discrepancy in the Φ∆values could be explained by the apparent photo‐decomposition of the later dye. Nevertheless, the high Φ∆value forQDMis unprecedented, as this chromophore exhibits relatively low structural complexity and could further be derivatized to create novel photodynamic agents.more » « less
-
Abstract In this work, we provide clear evidence of magnetic anisotropy in the local orbital moment of a molecular thin film based on the SCO complex [Fe(H2B(pz)2)2(bipy)] (pz = pyrazol−1−yl, bipy = 2,2′−bipyridine). Field dependent x-ray magnetic circular dichroism measurements indicate that the magnetic easy axis for the orbital moment is along the surface normal direction. Along with the presence of a critical field, our observation points to the existence of an anisotropic energy barrier in the high-spin state. The estimated nonzero coupling constant of ∼2.47 × 10−5eV molecule−1indicates that the observed magnetocrystalline anisotropy is mostly due to spin–orbit coupling. The spin- and orbital-component anisotropies are determined to be 30.9 and 5.04 meV molecule−1, respectively. Furthermore, the estimatedgfactor in the range of 2.2–2.45 is consistent with the expected values. This work has paved the way for an understanding of the spin-state-switching mechanism in the presence of magnetic perturbations.more » « less
An official website of the United States government
