Testing of Tsunami waves against a reinforced concrete core wall. The specimen was instrumented with three different types of instruments to measure load, pressure sensors on the front face of the specimen, strain gauges on the piles that supported the specimen, and load cells measuring the total force on the setup. The test specimen was placed inside a soil box with three different levels of soil examined to determine if changing the soil level changed the force in the support piles. Steam-wise force data was averaged across all trials for a given soil height and is presented for the three different force measurement techniques for the three different soil heights investigated. Wave gauge and ADV measurements are averaged across all trials for the given wave height.
more »
« less
1.45m wave
Testing of Tsunami waves against a reinforced concrete core wall. The specimen was instrumented with three different types of instruments to measure load, pressure sensors on the front face of the specimen, strain gauges on the piles that supported the specimen, and load cells measuring the total force on the setup. Stream-wise force, wave height, and velocity data are presented as averages across all trials conducted for this experiment.
more »
« less
- Award ID(s):
- 1726326
- PAR ID:
- 10381988
- Publisher / Repository:
- Designsafe-CI
- Date Published:
- Subject(s) / Keyword(s):
- Analysis of the Data Information on test setup and specimen construction Stream-wise force data Free surface elevation and velocity Data Instrumentation Experimental Results Testing of a Reinforced Concrete Core Wall for Tsunami Vertical Evacuation Shelters in a Wave Flume Ohhwrl-Oregon
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Summary This paper presents a shake‐table test study to investigate the displacement capacity of shear‐dominated reinforced masonry wall systems and the influence of wall flanges and planar walls perpendicular to the direction of shaking (out‐of‐plane walls) on the seismic performance of a wall system. Two full‐scale, single‐story, fully grouted, reinforced masonry wall specimens were tested to the verge of collapse. Each specimen had two T‐walls as the seismic force‐resisting elements and a stiff roof diaphragm. The second specimen had six additional planar walls perpendicular to the direction of shaking. The two specimens reached maximum roof drift ratios of 17% and 13%, without collapsing. The high displacement capacities can be largely attributed to the presence of wall flanges and, for the second specimen, also the out‐of‐plane walls, which provided an alternative load path to carry the gravity load when the webs of the T‐walls had been severely damaged. The second specimen developed a higher lateral resistance than the first owing to the additional axial compression exerted on the T‐walls by the out‐of‐plane walls when the former rocked. The shear resistance of the T‐walls evaluated with the design code formula matches the test result well when this additional axial compression is taken into account. However, it must be understood that the beneficial influence of the wall flanges depends on the magnitude of the gravity load because of the P‐Δ effect and the severity of damage induced in the wall flanges when the wall system is subjected to bidirectional ground motions.more » « less
-
An on-grade and an elevated specimen were tested and exposed to regular waves, in the Directional Wave Basin (DWB) at Oregon State University, with varying water depths and wave heights to simulate typical wave/surge conditions resulting from landfall hurricanes on low-lying barrier islands such as Hurricane Sandy that impacted the US East Coast in 2012 and Hurricane Ike that impacted the US Gulf Coast in 2008. Several instruments were used in the experiment, including nine wire resistance wave gauges located offshore, eight ultrasonic wave gauges located onshore near the specimens, four acoustic-doppler velocimeters, twelve pressure sensors, four load cells, and four triaxial accelerometers located on the specimens. The data (water depth, wave height, velocity, pressure, force, acceleration) gathered can help engineers and numerical modelers better understand the wave-structure interaction and help in improving design criteria of coastal light wood frame residential structures subjected to hurricane overland surge and wave loading.more » « less
-
This experimental project investigated the debris accumulation in front of structures during tsunamis (debris damming), which leads to an increase in the forces imposed by tsunami flow on structures. The study was conducted through the construction of a 1:20 geometric scale physical model. Tsunami-like waves were generated over an idealized slope and transported different shapes of multi-debris, representing shipping containers, over the flat test section to measure debris loadings on elevated column structures. The experiment optically measured the debris impact and damming process, along with the corresponding loads on the entire column structure using a Force Balance Plate and separately on an individual column in the front row using a load cell. This unique data set will help to understand the impact of various factors on debris-driven damming loads, including wave characteristics, specimen configurations, and debris shapes. This data will also help to develop and validate numerical models that predict the motion and dynamics of floating debris during extreme coastal events. This project is the outcome of “Collaborative Research: Experimental Quantification of Tsunami-driven Debris Damming on Structures” with collaborators from the University of Hawaii at Manoa, Louisiana State University, and Oregon State University.more » « less
-
In many applications, glass fabrics are subject to cyclic forces. Here we show that a glass fabric can tear under a much lower cyclic force than monotonic force. For samples of a given width, a threshold force exists below which the fabric does not tear under cyclic load, and a critical force exists at which the fabric tears under monotonic load. For example, for 80 mm wide sample, the threshold force is 12.78 N, and the critical force is 344.73 N. Under cyclic force of amplitude between the threshold force and critical force, tear initiates after some number of cycles. Under either cyclic or monotonic force, the fabric tears in three modes: pullout of transverse yarns, pullout of transverse yarns and break of longitudinal yarns, and break of transverse and longitudinal yarns. We summarize the observed tear modes on the plane of two axes: the amplitude of force and the width of sample. It is hoped that this study will aid the development of fatigue-resistant fabrics and fabric reinforced composites.more » « less
An official website of the United States government