- Award ID(s):
- 1717578
- NSF-PAR ID:
- 10382970
- Date Published:
- Journal Name:
- Applied Optics
- Volume:
- 61
- Issue:
- 6
- ISSN:
- 1559-128X
- Page Range / eLocation ID:
- C107
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
Coded aperture X-ray computed tomography is a computational imaging technique capable of reconstructing inner structures of an object from a reduced set of X-ray projection measurements. Coded apertures are placed in front of the X-ray sources from different views and thus significantly reduce the radiation dose. This paper introduces coded aperture X-ray computed tomography for robotic X-ray systems which offer positioning flexibility. While single coded-aperture 3D tomography was recently introduced for standard trajectory CT scanning, it is shown that significant gains in imaging performance can be attained by simple modifications in the CT scanning trajectories enabled by emerging dual robotic CT systems. In particular, the subject is fixed on a plane and the CT system uniformly rotates around the r −axis which is misaligned with the coordinate axes. A single stationary coded aperture is placed on front of the robotic X-ray source above the plane and the corresponding X-ray projections are measured by a two-dimensional detector on the second arm of the robotic system. The compressive measurements with misalignment enable the reconstruction of high-resolution three-dimensional volumetric images from the low-resolution coded projections on the detector at a sub-sampling rate. An efficient algorithm is proposed to generate the rotation matrix with two basic sub-matrices and thus the forward model is formulated. The stationary coded aperture is designed based on the Pearson product-moment correlation coefficient analysis and the direct binary search algorithm is used to obtain the optimized coded aperture. Simulations using simulated datasets show significant gains in reconstruction performance compared to conventional coded aperture CT systems.more » « less
-
Abstract: Coded aperture X-ray computed tomography (CT) has the potential to revolutionize X-ray tomography systems in medical imaging and air and rail transit security - both areas of global importance. It allows either a reduced set of measurements in X-ray CT without degrada- tion in image reconstruction, or measure multiplexed X-rays to simplify the sensing geometry. Measurement reduction is of particular interest in medical imaging to reduce radiation, and airport security often imposes practical constraints leading to limited angle geometries. Coded aperture compressive X-ray CT places a coded aperture pattern in front of the X-ray source in order to obtain patterned projections onto a detector. Compressive sensing (CS) reconstruction algorithms are then used to recover the image. To date, the coded illumination patterns used in conventional CT systems have been random. This paper addresses the code optimization prob- lem for general tomography imaging based on the point spread function (PSF) of the system, which is used as a measure of the sensing matrix quality which connects to the restricted isom- etry property (RIP) and coherence of the sensing matrix. The methods presented are general, simple to use, and can be easily extended to other imaging systems. Simulations are presented where the peak signal to noise ratios (PSNR) of the reconstructed images using optimized coded apertures exhibit significant gain over those attained by random coded apertures. Additionally, results using real X-ray tomography projections are presented.more » « less
-
Abstract: Coded aperture X-ray computed tomography (CT) has the potential to revolutionize X-ray tomography systems in medical imaging and air and rail transit security - both areas of global importance. It allows either a reduced set of measurements in X-ray CT without degrada- tion in image reconstruction, or measure multiplexed X-rays to simplify the sensing geometry. Measurement reduction is of particular interest in medical imaging to reduce radiation, and airport security often imposes practical constraints leading to limited angle geometries. Coded aperture compressive X-ray CT places a coded aperture pattern in front of the X-ray source in order to obtain patterned projections onto a detector. Compressive sensing (CS) reconstruction algorithms are then used to recover the image. To date, the coded illumination patterns used in conventional CT systems have been random. This paper addresses the code optimization prob- lem for general tomography imaging based on the point spread function (PSF) of the system, which is used as a measure of the sensing matrix quality which connects to the restricted isom- etry property (RIP) and coherence of the sensing matrix. The methods presented are general, simple to use, and can be easily extended to other imaging systems. Simulations are presented where the peak signal to noise ratios (PSNR) of the reconstructed images using optimized coded apertures exhibit significant gain over those attained by random coded apertures. Additionally, results using real X-ray tomography projections are presented.more » « less
-
Spectral computed tomography (SCT) makes use of the spectral dependence of X-ray attenuation in tissues and contrast agents to separate the attenuation data into more than two energy bins. Current SCT detectors are costly and the measured data have low signal to noise ratio due to the detector's narrow bin bandwidth and quantum noise. A new approach called coded aperture compressive X-ray SCT that combines a conventional rotating X-ray CT system with a set of pixelated K-edge coded apertures is introduced. In this method, the amplitude and spectra of the X-ray source are filtered by a particular pattern of K-edge filters in each view angle. Compressed sensing (CS) reconstruction algorithms are then used to recover the spectral CT image from the coded measurements. Simulations results for random coded apertures are shown, and their performance is compared to the use of uncoded measurements.more » « less
-
As the use of X-ray computed tomography (CT) grows in medical diagnosis, so does the concern for the harm a radiation dose can cause and the biological risks it represents. StaticCodeCT is a new low-dose imaging architecture that uses a single-static coded aperture (CA) in a CT gantry. It exploits the highly correlated data in the projection domain to estimate the unobserved measurements on the detector. We previously analyzed the StaticCodeCT system by emulating the effect of the coded mask on experimental CT data. In contrast, this manuscript presents test-bed reconstructions using an experimental cone-beam X-ray CT system with a CA holder. We analyzed the reconstruction quality using three different techniques to manufacture the CAs: metal additive manufacturing, cold casting, and ceramic additive manufacturing. Furthermore, we propose an optimization method to design the CA pattern based on the algorithm developed for the measurement estimation. The obtained results point to the possibility of the real deployment of StaticCodeCT systems in practice.