skip to main content


Title: Phase‐Modulated Interferometry, Spectroscopy, and Refractometry using Entangled Photon Pairs
Abstract

The authors demonstrate a form of two‐photon‐counting interferometry by measuring the coincidence counts between single‐photon‐counting detectors at an output port of a Mach–Zehnder Interferometer (MZI) following injection of broad‐band time‐frequency‐entangled photon pairs (EPP) generated from collinear spontaneous parametric down conversion into a single input port. Spectroscopy and refractometry are performed on a sample inserted in one internal path of the MZI by scanning the other path in length, which acquires phase and amplitude information about the sample's linear response. Phase modulation and lock‐in detection are introduced to increase detection signal‐to‐noise ratio and implement a “down‐sampling” technique for scanning the interferometer delay, which reduces the sampling requirements needed to reproduce fully the temporal interference pattern. The phase‐modulation technique also allows the contributions of various quantum‐state pathways leading to the final detection outcomes to be extracted individually. Feynman diagrams frequently used in the context of molecular spectroscopy are used to describe the interferences resulting from the coherence properties of time‐frequency EPPs passing through the MZI. These results are an important step toward the implementation of a proposed method for molecular spectroscopy—quantum‐light‐enhanced 2D spectroscopy.

 
more » « less
Award ID(s):
1839216
NSF-PAR ID:
10384662
Author(s) / Creator(s):
 ;  ;  ;  ;  ;  
Publisher / Repository:
Wiley Blackwell (John Wiley & Sons)
Date Published:
Journal Name:
Advanced Quantum Technologies
Volume:
3
Issue:
11
ISSN:
2511-9044
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Fluorescence-detected Fourier transform (FT) spectroscopy is a technique in which the relative paths of an optical interferometer are controlled to excite a material sample, and the ensuing fluorescence is detected as a function of the interferometer path delay and relative phase. A common approach to enhance the signal-to-noise ratio in these experiments is to apply a continuous phase sweep to the relative optical path, and to detect the resulting modulated fluorescence using a phase-sensitive lock-in amplifier. In many important situations, the fluorescence signal is too weak to be measured using a lock-in amplifier, so that photon counting techniques are preferred. Here we introduce an approach to low-signal fluorescence-detected FT spectroscopy, in which individual photon counts are assigned to a modulated interferometer phase (‘phase-tagged photon counting,’ or PTPC), and the resulting data are processed to construct optical spectra. We studied the fluorescence signals of a molecular sample excited resonantly by a pulsed coherent laser over a range of photon flux and visibility levels. We compare the performance of PTPC to standard lock-in detection methods and establish the range of signal parameters over which meaningful measurements can be carried out. We find that PTPC generally outperforms the lock-in detection method, with the dominant source of measurement uncertainty being associated with the statistics of the finite number of samples of the photon detection rate.

     
    more » « less
  2. In this theoretical study, we show how photoelectron signals generated by time-energy entangled photon pairs can monitor ultrafast excited state dynamics of molecules with high joint spectral and temporal resolutions, not limited by the Fourier uncertainty of classical light. This technique scales linearly, rather than quadratically, with the pump intensity, allowing the study of fragile biological samples with low photon fluxes. Since the spectral resolution is achieved by electron detection and the temporal resolution by a variable phase delay, this technique does not require scanning the pump frequency and the entanglement times, which significantly simplifies the experimental setup, making it feasible with current instrumentation. Application is made to the photodissociation dynamics of pyrrole calculated by exact nonadiabatic wave packet simulations in a reduced two nuclear coordinate space. This study demonstrates the unique advantages of ultrafast quantum light spectroscopy.

     
    more » « less
  3. Interest in layered two-dimensional (2D) materials has been escalating rapidly over the past few decades due to their promising optoelectronic and photonic properties emerging from their atomically thin 2D structural confinements. When these 2D materials are further confined in lateral dimensions toward zero-dimensional (0D) structures, 2D nanoparticles and quantum dots with new properties can be formed. Here, we report a nonequilibrium gas-phase synthesis method for the stoichiometric formation of gallium selenide (GaSe) nanoparticles ensembles that can potentially serve as quantum dots. We show that the laser ablation of a target in an argon background gas condenses the laser-generated plume, resulting in the formation of metastable nanoparticles in the gas phase. The deposition of these nanoparticles onto the substrate results in the formation of nanoparticle ensembles, which are then post-processed to crystallize or sinter the nanoparticles. The effects of background gas pressures, in addition to crystallization/sintering temperatures, are systematically studied. Scanning electron microscopy (SEM), transmission electron microscopy (TEM), photoluminescence (PL) spectroscopy, and time-correlated single-photon counting (TCSPC) measurements are used to study the correlations between growth parameters, morphology, and optical properties of the fabricated 2D nanoparticle ensembles. 
    more » « less
  4. Miller, Benjamin L. ; Weiss, Sharon M. ; Danielli, Amos (Ed.)
    Evanescent field silicon photonics in a silicon-on-insulator or silicon-nitride-on-insulator platforms have been effectively utilized to demonstrate chemical and biosensors over the past decade with applications in the detection of nucleic acids and protein biomarkers for cancers, viruses and infectious diseases, and environmental toxins. By balancing the requirements for efficient low-loss transmission through the waveguide and enhancing light-matter interaction such as with molecules binding on the high index material surfaces in resonant microcavities, slow light and interferometer geometries, various high sensitivity biosensors have been experimentally demonstrated down to few femtograms/ml. various slotted microcavities and waveguides have been experimentally demonstrated. In recent years, subwavelength waveguides have demonstrated high bulk spectral sensitivities approaching ~500nm/RIU (RIU=refractive index unit) in periodic structures with lattice constant (Λ) <<(λ/2n eff ) where n eff is the effective index at wavelength λ. While most experimental demonstrations have been in subwavelength ring resonator geometries, in this research, in addition to experimental demonstration of bulk spectral sensitivity ~775nm/RIU in subwavelength waveguides in interferometer configurations, we investigate optimized geometries that can reach sensitivities ~70,000nm/RIU in compact dimensions. In contrast to Mach-Zehnder interferometer (MZI) sensors of the same geometric interferometer arm lengths, the reflected path in Michelson interferometers (MI) doubles the optical path length, and thus effectively doubles the phase shift in the presence of an analyte. The interference fringe linewidths are narrowed compared to the equivalent MZI and would thus enable smaller changes in analyte concentration to be discerned from the fringe spectra. 
    more » « less
  5. Abstract

    A unique method is presented for the acquisition and analysis of57Fe backscatter Mössbauer spectra with simultaneous detection of the resonant 14.4 keVγ-rays and the characteristic 6.4 keV x-rays, using a custom-built multi-parameter analyser constructed on the basis of commercial analogue to digital converters and high-speed digital latches. The system allows for the simultaneous registration of Doppler-modulation velocities and photon energies, with up to 4096 and 8192 digital channels respectively. This arrangement is in contrast to most related systems, which detect at a single narrow energy window per detector. Samples of arbitrary atomic structure, morphology and surface topography can be studied without altering the setup or the analysis procedure, provided that the samples are at least micrometre sized. The hardware and software that are used to acquire data with minimal dead time are described and the custom and self-contained methods for post-measurement energy discrimination, background correction and velocity-axis folding are discussed. The data are fit using a general Hamiltonian model for the nuclear energy levels of57Fe and a quantum mechanical description of the angular momentum coupling is utilised, with consideration of the crystalline and chemical disorder of the sample under examination. Three examples of distinct magnetic systems, with thicknesses ranging from5μm to 6 mm, that were studied using this method are presented, these are: an amorphous CoFeB-based ribbon with ultra-soft coercivity for high-frequency applications, magnetically hard Nd-Fe-B thick films on Si substrates, examined in both as-deposited and annealed states, and a sample from the nickel-rich iron meteorite NWA 6259 that contains the atomically ordered, elevated coercivity,L10phase of FeNi, tetrataenite. The wide applicability and usefulness of this method is thus demonstrated on three distinct sample morphologies that required little to no surface preparation prior to examination.

     
    more » « less