Title: Enabling Higher Performance Concentric Tube Robots Via Multiple Constant-Curvature Tubes
Concentric tube robots (CTRs) consist of a set of telescoping, pre-curved tubes, whose overall shape can be actively controlled by translating and rotating the tubes with respect to each other. The majority of CTRs to date consist of piecewise constant-curvature tubes, with a straight section followed by a single constant-curvature section. Several approaches have been proposed for CTR designs that can lead to improvements in metrics such as the workspace, orientability, dexterity, and stability. Here we propose to use CTRs with multiple constant-curvature sections. We perform two simulation studies that compare the performance of the multiple constant- curvature CTRs with standard single constant-curvature tubes. We also demonstrate how using one of the proposed multiple constant-curvature designs can enable the reduction in the number of tubes needed to achieve the same performance as a standard three-tube CTR.  more » « less
Award ID(s):
2146095
PAR ID:
10402472
Author(s) / Creator(s):
; ; ;
Date Published:
Journal Name:
International Symposium on Medical Robotics
ISSN:
2771-9049
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Concentric tube robots (CTRs) have drawn significant research attention over the years, particularly due to their applications in minimally invasive surgery (MIS). Indeed, their small size, flexibility, and high dexterity enable several potential benefits for MIS. Research has led to an increasing number of discoveries and scientific breakthroughs in CTR design, fabrication, control, and applications. Numerous prototypes have emerged from different research groups, each with their own design and specifications. This survey paper provides an overview of the state-of-the-art of the mechatronics aspects of CTRs, including approaches for the design and fabrication of the tubes, actuation unit, and end effector. In addition to the various hardware and associated fabrication methods, we propose to the research community, a unifying way of classifying CTRs based on their actuation unit architecture, as well as a set of specification details for evaluation of future CTR prototypes. Finally, we also aim to highlight the current advancements, challenges, and perspectives of CTR design and fabrication. 
    more » « less
  2. This paper proposes a novel flexible pneumatic valve adapter that seeks inspiration from vascular systems found in nature. Evolved vascular systems, such as the human cardiovascular system, pump fluid through a complex system composed of a single reservoir/pump. These systems regulate flow by systematically closing and opening valves appropriately through soft biological material constriction. The proposed pneumatic valve emulates this with two concentric flexible tubes with a single hole on the inner tube and patterned holes on the outer tube. This allows it to decrease the quantity of tubes and valves required for pneumatically actuated soft robots, with the trade-off being increased motion of the valve spool (the inner tube). Previous versions of this adapter used rigid members which decreased the number of tubes tethering the robot to a pressure source, but also hindered the soft robotic nature and movement. This adapter utilizes flexible materials to minimize the valve’s effect on the robot’s range of motion. The tubes have holes that are patterned by custom design determined by the needs of the soft robot with which it is to be used. The inner tube can be moved rotationally or translationally within the outer tube to align with designated holes to pressurize and depressurize chambers in a soft robot with only a single lightweight valve. 
    more » « less
  3. null (Ed.)
    Abstract This paper proposes a novel pneumatic valve adapter that decreases the size and quantity of pneumatic tubes and valves necessary for soft robotics by mimicking cardiovascular systems. Some cardiovascular systems, evolved to be powered by a single reservoir, the heart, which in turn powers the rest of the body by systematically opening and closing valves as needed. The presented valve adapter consists of a set of concentric tube, where both tubes have strategically patterned holes. The inner tube can be moved translationally and rotationally to align with designated hole positions in the outer tube, thus opening and closing pathways to chambers for pressure flow. The two-tube system can be used to either pressurize a chamber or depressurize a chamber or multiple chambers simultaneously. 
    more » « less
  4. null (Ed.)
    We study the security of CTR-DRBG , one of NIST’s recommended Pseudorandom Number Generator (PRNG) designs. Recently, Woodage and Shumow (Eurocrypt’ 19), and then Cohney et al. (S&P’ 20) point out some potential vulnerabilities in both NIST specification and common implementations of CTR-DRBG . While these researchers do suggest counter-measures, the security of the patched CTR-DRBG is still questionable. Our work fills this gap, proving that CTR-DRBG satisfies the robustness notion of Dodis et al. (CCS’13), the standard security goal for PRNGs. 
    more » « less
  5. Abstract Thin-walled corrugated tubes that have a bending multistability, such as the bendy straw, allow for variable orientations over the tube length. Compared to the long history of corrugated tubes in practical applications, the mechanics of the bending stability and how it is affected by the cross sections and other geometric parameters remain unknown. To explore the geometry-driven bending stabilities, we used several tools, including a reduced-order simulation package, a simplified linkage model, and physical prototypes. We found the bending stability of a circular two-unit corrugated tube is dependent on the longitudinal geometry and the stiffness of the crease lines that connect separate frusta. Thinner shells, steeper cones, and weaker creases are required to achieve bending bi-stability. We then explored how the bending stability changes as the cross section becomes elongated or distorted with concavity. We found the bending bi-stability is favored by deep and convex cross sections, while wider cross sections with a large concavity remain mono-stable. The different geometries influence the amounts of stretching and bending energy associated with bending the tube. The stretching energy has a bi-stable profile and can allow for a stable bent configuration, but it is counteracted by the bending energy which increases monotonically. The findings from this work can enable informed design of corrugated tube systems with desired bending stability behavior. 
    more » « less