Title: Ultra‐low current electrospray ionization of chloroform solution for the analysis of perfluorinated sulfonic acids
RationaleFemtoamp and picoamp electrospray ionization (ESI) characteristics of a nonpolar solvent were explored. The direct ESI mass spectrometry analysis of chloroform extract solution enabled rapid analysis of perfluorinated sulfonic acid analytes in drinking water. MethodsNeat chloroform solvent and extracts were directly used in a typical wire‐in ESI setup using micrometer emitter tips. Ionization currents were measured with femtoamp sensitivity while ramping the spray voltage from 0 to −5000 V. Methanol was used as a comparison to illustrate the characteristics of electrospraying chloroform. The effects of spray voltage and inlet temperature were studied. A liquid–liquid extraction workflow was developed to analyze perfluorooctanoate sulfonate (PFOS) in drinking water using an ion‐trap mass spectrometer. ResultsThe ionization onset of chloroform solution was 41 ± 17 fA at 300 V. The ionization current gradually increased with voltage while remaining below 100 pA when using voltages up to −5000 V. The ion signal of PFOS was significantly enhanced to improve the limit of detection (LoD) to 25 ppt in chloroform. Coupled with a liquid–liquid extraction workflow, LoD of 0.38–5.1 ppt and a quantitation range of 5–400 ppt were achieved for perfluorinated sulfonic compounds in 1‐ml water samples. ConclusionsFemtoamp and picoamp modes expand the solvent compatibility range of ESI and can enable quantitative analysis in parts per trillion (ppt) concentrations.  more » « less
Award ID(s):
2203289
PAR ID:
10403153
Author(s) / Creator(s):
 ;  ;  ;  ;  
Publisher / Repository:
Wiley Blackwell (John Wiley & Sons)
Date Published:
Journal Name:
Rapid Communications in Mass Spectrometry
Volume:
37
Issue:
S1
ISSN:
0951-4198
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. RationalePurification of recombinant proteins is a necessary step for functional or structural studies and other applications. Immobilized metal affinity chromatography is a common recombinant protein purification method. Mass spectrometry (MS) allows for confirmation of identity of expressed proteins and unambiguous detection of enzymatic substrates and reaction products. We demonstrate the detection of enzymes purified on immobilized metal affinity surfaces by direct or ambient ionization MS, and follow their enzymatic reactions by direct electrospray ionization (ESI) or desorption electrospray ionization (DESI). MethodsA protein standard, His‐Ubq, and two recombinant proteins, His‐SHAN and His‐CS, expressed inEscherichia coliwere immobilized on two immobilized metal affinity systems, Cu–nitriloacetic acid (Cu‐NTA) and Ni‐NTA. The proteins were purified on surface, and released in the ESI spray solvent for direct infusion, when using the 96‐well plate form factor, or analyzed directly from immobilized metal affinity‐coated microscope slides by DESI‐MS. Enzyme activity was followed by incubating the substrates in wells or by depositing substrate on immobilized protein on coated slides for analysis. ResultsSmall proteins (His‐Ubq) and medium proteins (His‐SAHN) could readily be detected from 96‐well plates by direct infusion ESI, or from microscope slides by DESI‐MS after purification on surface from clarifiedE. colicell lysate. Protein oxidation was observed for immobilized proteins on both Cu‐NTA and Ni‐NTA; however, this did not hamper the enzymatic reactions of these proteins. Both the nucleosidase reaction products for His‐SAHN and the methylation product of His‐CS (theobromine to caffeine) were detected. ConclusionsThe immobilization, purification, release and detection of His‐tagged recombinant proteins using immobilized metal affinity surfaces for direct infusion ESI‐MS or ambient DESI‐MS analyses were successfully demonstrated. Recombinant proteins were purified to allow identification directly out of clarified cell lysate. Biological activities of the recombinant proteins were preserved allowing the investigation of enzymatic activity via MS. 
    more » « less
  2. Abstract Matrix components are known to significantly alter the ionization of a target analyte in ESI‐based measurements particularly when working with complex biological samples. This issue however may be alleviated by extracting the analyte of interest from the original sample into a relatively simple matrix compatible with ESI mass‐spectrometric analysis. In this article, we report a microfluidic device that enables such extraction of small peptide molecules into an ESI‐compatible solvent stream significantly improving both the sensitivity and reproducibility of the measurements. The reported device realizes this analyte extraction capability based on the free‐flow zone electrophoretic fractionation process using a set of internal electrodes placed across the width of the analysis channel. Employing lateral electric fields and separation distances of 75 V/cm and 600 µm, respectively, efficient extraction of the model peptide human angiotensin II was demonstrated allowing a reduction in its detection limit by one to three orders of magnitude using the ESI‐MS method. The noted result was obtained in our experiments both for a relatively simple specimen comprising DNA strands and angiotensin II as well as for human serum samples spiked with the same model peptide. 
    more » « less
  3. Abstract The determination of gas phase thermochemical properties of per‐ and polyfluoroalkyl substances (PFAS) is central to understanding the long‐range transport behavior of PFAS in the atmosphere. Prior gas‐phase studies have reported the properties of perfluorinated sulfonic acid (PFOS) and perfluorinated octanoic acid (PFOA). Here, this study reports the gas phase enthalpies of formation of short‐ and long‐chain PFAS and their precursor molecules determined using density functional theory (DFT) andab initioapproaches. Two density functionals, twoab initiomethods and an empirical method were used to compute enthalpies of formation with the total atomization approach and an isogyric reaction. The performance of the computational methods employed in this work were validated against the experimental enthalpies of linear alkanoic acids and perfluoroalkanes. The gas‐phase determinations will be useful for future studies of PFAS in the atmosphere, and the methodological choices will be helpful in the study of other PFAS. 
    more » « less
  4. RationaleIn droplet‐assisted ionization (DAI), intact molecular ions are generated from molecules in aerosol droplets by passing the droplets through a temperature‐controlled capillary inlet. Ion formation is explored through the effects of analyte mass flow, droplet solvent composition, and capillary temperature on ion signal intensity. MethodsA Waters SYNAPT G2‐S is adapted for DAI by reconfiguring the inlet with a temperature‐controlled capillary. Droplets are generated by atomization of a solution containing analyte and then sampled through the inlet. If desired, solvent can be removed from the droplets prior to analysis by sending the aerosol through a series of diffusion dryers. Size distributions of the dried aerosols allow the mass flow of analyte into the inlet to be determined. ResultsAnalyte signal intensities are orders of magnitude higher from droplets containing a protic solvent (water) than an aprotic solvent (acetonitrile). The highest signal intensities for DAI are obtained with inlet temperatures above 500°C, though the optimum temperature is analyte dependent. At elevated temperatures, droplets are thought to undergo rapid solvent evaporation and bursting to produce ions. The lowest signal intensities are generally obtained in the 100–350°C range, where slow solvent evaporation is thought to inhibit ion formation. As the temperature decreases from 100°C down to 25°C, the signal intensity increases significantly. When 3‐nitrobenzonitrile, a common matrix for solid‐state matrix‐assisted ionization (MAI), is added to droplets consisting of 50/50 v/v water and acetonitrile, the matrix enhances ion formation to produce a signal intensity comparable to DAI in 100% water. ConclusionsThe results are consistent with other inlet ionization techniques, suggesting that similar ion formation mechanisms are operative. Optimized ion yields (the combined effects of ionization probability and ion transmission) for DAI are currently in the 10−5to 10−6range, which is sufficient for many aerosol applications. 
    more » « less
  5. RationaleThe developments of new ionization technologies based on processes previously unknown to mass spectrometry (MS) have gained significant momentum. Herein we address the importance of understanding these unique ionization processes, demonstrate the new capabilities currently unmet by other methods, and outline their considerable analytical potential. MethodsTheinletandvacuumionization methods of solvent‐assisted ionization (SAI), matrix‐assisted ionization (MAI), and laserspray ionization can be used with commercial and dedicated ion sources producing ions from atmospheric or vacuum conditions for analyses of a variety of materials including drugs, lipids, and proteins introduced from well plates, pipet tips and plate surfaces with and without a laser using solid or solvent matrices. Mass spectrometers from various vendors are employed. ResultsResults are presented highlighting strengths relative to ionization methods of electrospray ionization (ESI) and matrix‐assisted laser desorption/ionization. We demonstrate the utility of multi‐ionization platforms encompassing MAI, SAI, and ESI and enabling detection of what otherwise is missed, especially when directly analyzing mixtures. Unmatched robustness is achieved with dedicated vacuum MAI sources with mechanical introduction of the sample to the sub‐atmospheric pressure (vacuumMAI). Simplicity and use of a wide array of matrices are attained using a conduit (inletionization), preferably heated, with sample introduction from atmospheric pressure. Tissue, whole blood, urine (including mouse, chicken, and human origin), bacteria strains and chemical on‐probe reactions are analyzed directly and, especially in the case ofvacuumionization, without concern of carryover or instrument contamination. ConclusionsExamples are provided highlighting the exceptional analytical capabilities associated with the novel ionization processes in MS that reduce operational complexity while increasing speed and robustness, achieving mass spectra with low background for improved sensitivity, suggesting the potential of this simple ionization technology to drive MS into areas currently underserved, such as clinical and medical applications. 
    more » « less