Title: On-axis deflectometric system for freeform surface measurement

We propose an on-axis deflectometric system for the accurate measurement of freeform surfaces with large slope ranges. A miniature plane mirror is attached on the illumination screen to fold the optical path and achieve the on-axis deflectometric testing. Due to the existence of the miniature folding mirror, the deep-learning method is applied to recover the missing surface data in a single measurement. Low sensitivity to the calibration error of system geometry and high testing accuracy can be achieved with the proposed system. The feasibility and accuracy of the proposed system have been validated. The system is low in cost and simple in configuration, and it provides a feasible way for the flexible and general testing of freeform surfaces, with a significant potential of the application in on-machine testing.

 
more » « less
Award ID(s):
1918260
PAR ID:
10404986
Author(s) / Creator(s):
; ; ;
Publisher / Repository:
Optical Society of America
Date Published:
Journal Name:
Optics Letters
Volume:
48
Issue:
8
ISSN:
0146-9592; OPLEDP
Format(s):
Medium: X Size: Article No. 1986
Size(s):
Article No. 1986
Sponsoring Org:
National Science Foundation
More Like this
  1. When conducting interferometric tests of freeform optical surfaces, additional optical components, such as computer-generated holograms or deformable mirrors, are often necessary to achieve a null or quasi-null. These additional optical components increase both the cost and the difficulty of interferometric tests of freeform optical surfaces. In this paper, designs using off-axis segments of conics as base surfaces for freeforms are explored. These off-axis conics are more complex base surfaces than typically-used base spheres but remain null-testable. By leveraging off-axis conics in conjunction with additional orthogonal polynomial departures, designs were found with up to an order-of-magnitude of improvement in testability estimates relative to designs that use base spheres. Two design studies, a three-mirror telescope and a wide field-of-view four-mirror telescope, demonstrate the impact of using off-axis conics as the base surface.

     
    more » « less
  2. Reimaging telescopes have an accessible exit pupil that facilitates stray light mitigation and matching to auxiliary optical systems. Freeform surfaces present the opportunity for unobscured reflective systems to be folded into geometries that are otherwise impracticable with conventional surface types. It is critical, however, to understand the limitations of the enabled folding geometries and choose the one that best balances the optical performance and mechanical requirements. Here, we used the aberration theory of freeform surfaces to determine the aberration correction potential for using freeform surfaces in reimaging three-mirror telescopes and established a hierarchy for the different folding geometries without using optimization. We found that when using freeform optics, the ideal folding geometry had 9× better wavefront performance compared to the next best geometry. Within that ideal geometry, the system using freeform optics had 39% better wavefront performance compared to a system using off-axis asphere surfaces, thus quantifying one of the advantages of freeform optics in this design space. 
    more » « less
  3. Driven by the development of freeform imaging systems, we have combined several concepts and techniques from the literature to analytically generate unobscured freeform starting point designs that are corrected through the third-order image degrading aberrations. The surfaces used in these starting point designs are described as a base off-axis conic that images stigmatically for the central field point, also known as a Cartesian reflector, with an aspheric departure “cap” (quartic with the aperture) added to the base off-axis conic to correct for the third-order image degrading aberrations. Once the aspheric caps are added to the surfaces, the system is then optimized using higher order freeform terms while leaving second-order terms frozen to preserve the focal length of the system during optimization. This technique is used to survey the three-mirror freeform imager solution space. Several systems that are the result of this technique are shown, with different numbers of internal images, internal pupil conjugates and folding geometries. 
    more » « less
  4. An approach to designing multiconfiguration afocal telescopes is developed and demonstrated. Freeform surfaces are used to maximize the achievable diffraction-limited zoom ratio while staying in a compact volume for a two-position multiconfiguration afocal optical system. The limitations of these systems with three-mirror beam paths are discussed and subsequently overcome by introducing an additional degree of freedom. In a four-mirror beam path system, the goal of a 5x zoom ratio is achieved with a compensated exit pupil and diffraction-limited performance. A significant benefit in optical performance when using freeform surfaces is shown compared to more conventional surface types.

     
    more » « less
  5. Freeform optical components enable dramatic advances for optical systems in both performance and packaging. Surface form metrology of manufactured freeform optics remains a challenge and an active area of research. Towards addressing this challenge, we previously reported on a novel architecture, cascade optical coherence tomography (C-OCT), which was validated for its ability of high-precision sag measurement at a given point. Here, we demonstrate freeform surface measurements, enabled by the development of a custom optical-relay-based scanning mechanism and a unique high-speed rotation mechanism. Experimental results on a flat mirror demonstrate an RMS flatness of 14 nm (∼λ/44 at the He-Ne wavelength). Measurement on a freeform mirror is achieved with an RMS residual of 69 nm (∼λ/9). The system-level investigations and validation provide the groundwork for advancing C-OCT as a viable freeform metrology technique.

     
    more » « less