Title: Coupling analysis of heart rate variability and cortical arousal using a deep learning algorithm
Frequent cortical arousal is associated with cardiovascular dysfunction among people with sleep-disordered breathing. Changes in heart rate variability (HRV) can represent pathological conditions associated with autonomic nervous system dysfunction. Previous studies showed changes in cardiac activity due to cortical arousals. However, few studies have examined the instantaneous association between cortical arousal and HRV in an ethnically diverse population. In this study, we included 1,069 subjects’ full night ECG signals from unattended polysomnography in the Multi-Ethnic Study of Atherosclerosis dataset. An automated deep learning tool was employed to annotate arousal events from ECG signals. The etiology (e.g., respiratory, or spontaneous) of each arousal event was classified through a temporal analysis. Time domain HRVs and mean heart rate were calculated on pre-, intra-, and post-arousal segments of a 25-s period for each arousal event. We observed that heart rate and HRVs increased during the arousal onsets in the intra-arousal segments, regardless of arousal etiology. Furthermore, HRVs response to cortical arousal occurrence differed according to gender and the sleep stages in which arousal occurred. The more intense HRVs variation due to arousal in females can contribute to a potentially stronger association between arousal burden and long-term mortality. The excessive abrupt sympathetic tone elevation in REM caused by arousal may provide insights on the association between sleep and sudden cardiac death.  more » « less
Award ID(s):
2052528
PAR ID:
10410748
Author(s) / Creator(s):
; ; ;
Editor(s):
Veauthier, Christian
Date Published:
Journal Name:
PLOS ONE
Volume:
18
Issue:
4
ISSN:
1932-6203
Page Range / eLocation ID:
e0284167
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Heart rate variability (HRV) features support several clinical applications, including sleep staging, and ballistocardiograms (BCGs) can be used to unobtrusively estimate these features. Electrocardiography is the traditional clinical standard for HRV estimation, but BCGs and electrocardiograms (ECGs) yield different estimates for heartbeat intervals (HBIs), leading to differences in calculated HRV parameters. This study examines the viability of using BCG-based HRV features for sleep staging by quantifying the impact of these timing differences on the resulting parameters of interest. We introduced a range of synthetic time offsets to simulate the differences between BCG- and ECG-based heartbeat intervals, and the resulting HRV features are used to perform sleep staging. Subsequently, we draw a relationship between the mean absolute error in HBIs and the resulting sleep-staging performances. We also extend our previous work in heartbeat interval identification algorithms to demonstrate that our simulated timing jitters are close representatives of errors between heartbeat interval measurements. This work indicates that BCG-based sleep staging can produce accuracies comparable to ECG-based techniques such that at an HBI error range of up to 60 ms, the sleep-scoring error could increase from 17% to 25% based on one of the scenarios we examined. 
    more » « less
  2. Using wireless signals to monitor human vital signs, especially heartbeat information, has been intensively studied in the past decade. This non-contact sensing modality can drive various applications from cardiac health, sleep, and emotion management. Under the circumstance of the COVID-19 pandemic, non-contact heart monitoring receives increasingly market demands. However, existing wireless heart monitoring schemes can only detect limited heart activities, such as heart rate, fiducial points, and Seismocardiography (SCG)-like information. In this paper, we present CardiacWave to enable a non-contact high-definition heart monitoring. CardiacWave can provide a full spectrum of Electrocardiogram (ECG)-like heart activities, including the details of P-wave, T-wave, and QRS complex. Specifically, CardiacWave is built upon the Cardiac-mmWave scattering effect (CaSE), which is a variable frequency response of the cardiac electromagnetic field under the mmWave interrogation. The CardiacWave design consists of a noise-resistant sensing scheme to interrogate CaSE and a cardiac activity profiling module for extracting cardiac electrical activities from the interrogation response. Our experiments show that the CardiacWave-induced ECG measures have a high positive correlation with the heart activity ground truth (i.e., measurements from a medical-grade instrument). The timing difference of P-waves, T-waves, and QRS complex is 0.67%, 0.71%, and 0.49%, respectively, and a mean cardiac event difference is within a delay of 5.3 milliseconds. These results indicate that CaridacWave offers high-fidelity and integral heart clinical characteristics. Furthermore, we evaluate the CardiacWave system with participants under various conditions, including heart and breath rates, ages, and heart habits (e.g., tobacco use). 
    more » « less
  3. Sleep is a vital physiological state that significantly impacts overall health. Continuous monitoring of sleep posture, heart rate, respiratory rate, and body movement is crucial for diagnosing and managing sleep disorders. Current monitoring solutions often disrupt natural sleep due to discomfort or raise privacy and instrumentation concerns. We introduce PillowSense, a fabric-based sleep monitoring system seamlessly integrated into a pillowcase. PillowSense utilizes a dual-layer fabric design. The top layer comprises conductive fabrics for sensing electrocardiogram (ECG) and surface electromyogram (sEMG), while the bottom layer features pressure-sensitive fabrics to monitor sleep location and movement. The system processes ECG and sEMG signals sequentially to infer multiple sleep variables and incorporates an adversarial neural network to enhance posture classification accuracy. We fabricate prototypes using off-the-shelf hardware and conduct both lab-based and in-the-wild longitudinal user studies to evaluate the system's effectiveness. Across 151 nights and 912.2 hours of real-world sleep data, the system achieves an F1 score of 88% for classifying seven sleep postures, and clinically-acceptable accuracy in vital sign monitoring. PillowSense's comfort, washability, and robustness in multi-user scenarios underscore its potential for unobtrusive, large-scale sleep monitoring. 
    more » « less
  4. Narratives can synchronize neural and physiological signals between individuals, but the relationship between these signals, and the underlying mechanism, is unclear. We hypothesized a top-down effect of cognition on arousal and predicted that auditory narratives will drive not only brain signals but also peripheral physiological signals. We find that auditory narratives entrained gaze variation, saccade initiation, pupil size, and heart rate. This is consistent with a top-down effect of cognition on autonomic function. We also hypothesized a bottom-up effect, whereby autonomic physiology affects arousal. Controlled breathing affected pupil size, and heart rate was entrained by controlled saccades. Additionally, fluctuations in heart rate preceded fluctuations of pupil size and brain signals. Gaze variation, pupil size, and heart rate were all associated with anterior-central brain signals. Together, these results suggest bidirectional causal effects between peripheral autonomic function and central brain circuits involved in the control of arousal. 
    more » « less
  5. Respiration rate and heart rate variability (HRV) due to respiratory sinus arrhythmia (RSA) are physiological measurements that can offer useful diagnostics for a variety of medical conditions. This study uses a wrist-worn wearable development platform from Maxim Integrated and Doppler radar sensor developed by Adnoviv, Inc. to non-invasively measure these physiological signals. Six datasets are recorded comprising of five different individuals in varying physical environments breathing at different respiration rates. First, respiration rates are extracted from photoplethysmography (PPG) and accelerometer data and compared to Doppler radar. The average maximum and minimum difference between Doppler radar extracted RR and PPG, HRV RSA, and accelerometer extracted RR is 0.342 b/m and 0.171 b/m, respectively. Then, waveforms for Doppler radar, PPG, and HRV RSA signals are plotted in time domain and an analysis discusses the physical phenomena associated with the phase alignment of the signals. 
    more » « less