skip to main content


Title: CardiacWave: A mmWave-based Scheme of Non-Contact and High-Definition Heart Activity Computing
Using wireless signals to monitor human vital signs, especially heartbeat information, has been intensively studied in the past decade. This non-contact sensing modality can drive various applications from cardiac health, sleep, and emotion management. Under the circumstance of the COVID-19 pandemic, non-contact heart monitoring receives increasingly market demands. However, existing wireless heart monitoring schemes can only detect limited heart activities, such as heart rate, fiducial points, and Seismocardiography (SCG)-like information. In this paper, we present CardiacWave to enable a non-contact high-definition heart monitoring. CardiacWave can provide a full spectrum of Electrocardiogram (ECG)-like heart activities, including the details of P-wave, T-wave, and QRS complex. Specifically, CardiacWave is built upon the Cardiac-mmWave scattering effect (CaSE), which is a variable frequency response of the cardiac electromagnetic field under the mmWave interrogation. The CardiacWave design consists of a noise-resistant sensing scheme to interrogate CaSE and a cardiac activity profiling module for extracting cardiac electrical activities from the interrogation response. Our experiments show that the CardiacWave-induced ECG measures have a high positive correlation with the heart activity ground truth (i.e., measurements from a medical-grade instrument). The timing difference of P-waves, T-waves, and QRS complex is 0.67%, 0.71%, and 0.49%, respectively, and a mean cardiac event difference is within a delay of 5.3 milliseconds. These results indicate that CaridacWave offers high-fidelity and integral heart clinical characteristics. Furthermore, we evaluate the CardiacWave system with participants under various conditions, including heart and breath rates, ages, and heart habits (e.g., tobacco use).  more » « less
Award ID(s):
1718375
NSF-PAR ID:
10386088
Author(s) / Creator(s):
; ; ; ; ; ; ; ;
Date Published:
Journal Name:
Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
Volume:
5
Issue:
3
ISSN:
2474-9567
Page Range / eLocation ID:
1 to 26
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract This study presents findings in the terahertz (THz) frequency spectrum for non-contact cardiac sensing applications. Cardiac pulse information is simultaneously extracted using THz waves based on the established principles in electronics and optics. The first fundamental principle is micro-Doppler motion effect. This motion based method, primarily using coherent phase information from the radar receiver, has been widely exploited in microwave frequency bands and has recently found popularity in millimeter waves (mmWave) for breathe rate and heart rate detection. The second fundamental principle is reflectance based optical measurement using infrared or visible light. The variation in the light reflection is proportional to the volumetric change of the heart, often referred as photoplethysmography (PPG). Herein, we introduce the concept of terahertz-wave-plethysmography (TPG), which detects blood volume changes in the upper dermis tissue layer by measuring the reflectance of THz waves, similar to the existing remote PPG (rPPG) principle. The TPG principle is justified by scientific deduction, electromagnetic wave simulations and carefully designed experimental demonstrations. Additionally, pulse measurements from various peripheral body parts of interest (BOI), palm, inner elbow, temple, fingertip and forehead, are demonstrated using a wideband THz sensing system developed by the Terahertz Electronics Lab at Arizona State University, Tempe. Among the BOIs under test, it is found that the measurements from forehead BOI gives the best accuracy with mean heart rate (HR) estimation error 1.51 beats per minute (BPM) and standard deviation 1.08 BPM. The results validate the feasibility of TPG for direct pulse monitoring. A comparative study on pulse sensitivity is conducted between TPG and rPPG. The results indicate that the TPG contains more pulsatile information from the forehead BOI than that in the rPPG signals in regular office lighting condition and thus generate better heart rate estimation statistic in the form of empirical cumulative distribution function of HR estimation error. Last but not least, TPG penetrability test for covered skin is demonstrated using two types of garment materials commonly used in daily life. 
    more » « less
  2. As the drone becomes widespread in numerous crucial applications with many powerful functionalities (e.g., reconnaissance and mechanical trigger), there are increasing cases related to misused drones for unethical even criminal activities. Therefore, it is of paramount importance to identify these malicious drones and track their origins using digital forensics. Traditional drone identification techniques for forensics (e.g., RF communication, ID landmarks using a camera, etc.) require high compliance of drones. However, malicious drones will not cooperate or even spoof these identification techniques. Therefore, we present an exploration for a reliable and passive identification approach based on unique hardware traits in drones directly (e.g., analogous to the fingerprint and iris in humans) for forensics purposes. Specifically, we investigate and model the behavior of the parasitic electronic elements under RF interrogation, a particular passive parasitic response modulated by an electronic system on drones, which is distinctive and unlikely to counterfeit. Based on this theory, we design and implement DroneTrace, an end-to-end reliable and passive identification system toward digital drone forensics. DroneTrace comprises a cost-effective millimeter-wave (mmWave) probe, a software framework to extract and process parasitic responses, and a customized deep neural network (DNN)-based algorithm to analyze and identify drones. We evaluate the performance of DroneTrace with 36 commodity drones. Results show that DroneTrace can identify drones with the accuracy of over 99% and an equal error rate (EER) of 0.009, under a 0.1-second sensing time budget. Moreover, we test the reliability, robustness, and performance variation under a set of real-world circumstances, where DroneTrace maintains accuracy of over 98%. DroneTrace is resilient to various attacks and maintains functionality. At its best, DroneTrace has the capacity to identify individual drones at the scale of 104 with less than 5% error. 
    more » « less
  3. Abstract

    Hotter summers caused by global warming and increased workload and duration are endangering the health of farmworkers, a high‐risk population for heat‐related illness (HRI), and deaths. Although prior studies using wearable sensors show the feasibility of employing field‐collected data for HRI monitoring, existing devices still have limitations, such as data loss from motion artifacts, device discomfort from rigid electronics, difficulties with administering ingestible sensors, and low temporal resolution. Here, this paper introduces a wireless, wearable bioelectronic system with functionalities for continuous monitoring of skin temperature, electrocardiograms (ECG), heart rates (HR), and activities, configured in a single integrated package. Advanced nanomanufacturing based on laser machining allows rapid device fabrication and direct incorporation of sensors with a highly breathable substrate, allowing for managing excessive sweating and multimodal stresses. To validate the device's performance in agricultural settings, the device is applied to multiple farmworkers at various operations, including fernery, nursery, and crop. The accurate data recording, including high‐fidelity ECG (signal‐to‐noise ratio: >20 dB), accurate HR (r= 0.89,r2= 0.65 in linear correlation), and reliable temperature/activity, confirms the device's capability for multiparameter health monitoring of farmworkers.

     
    more » « less
  4. Abstract Background

    A low electrocardiogram (ECG) lead one ratio (LOR) of the maximum positive/negative QRS amplitudes is associated with lower left ventricular ejection fraction (LVEF) and worse outcomes in left bundle branch block (LBBB); however, the impact of LOR on cardiac resynchronization therapy (CRT) outcomes is unknown. We compared clinical outcomes and echocardiographic changes after CRT implantation by LOR.

    Methods

    Consecutive CRT‐defibrillator recipients with LBBB implanted between 2006 and 2015 at Duke University Medical Center were included (N = 496). Time to heart transplant, left ventricular assist device (LVAD) implantation, or death was compared among patients with LOR <12 vs ≥12 using Cox‐proportional hazard models. Changes in LVEF and LV volumes after CRT were compared by LOR.

    Results

    Baseline ECG LOR <12 was associated with an adjusted hazard ratio (HR) of 1.69 (95% CI: 1.12‐2.40,P = .01) for heart transplant, LVAD, or death. Patients with LOR <12 had less reduction of LV end diastolic volume (ΔLVEDV −4 ± 21 vs −13 ± 23%,P = .04) and LV end systolic volume (ΔLVESV −9 ± 27 vs −22 ± 26%,P = .03) after CRT. In patients with QRS duration (QRSd) ≥150 ms, LOR <12 was associated with an adjusted HR of 2.01 (95% CI 1.21‐3.35,P = .008) for heart transplant, LVAD, or death, compared with LOR ≥12.

    Conclusions

    Baseline ECG LOR <12 portends worse outcomes after CRT implantation in patients with LBBB, specifically among those with QRSd ≥150 ms. This ECG ratio may identify patients with a class I indication for CRT implantation at high risk for poor postimplantation outcomes.

     
    more » « less
  5. Abstract

    Heart rhythm assessment is indispensable in diagnosis and management of many cardiac conditions and to study heart rate variability in healthy individuals. We present a proof-of-concept system for acquiring individual heart beats using smart speakers in a fully contact-free manner. Our algorithms transform the smart speaker into a short-range active sonar system and measure heart rate and inter-beat intervals (R-R intervals) for both regular and irregular rhythms. The smart speaker emits inaudible 18–22 kHz sound and receives echoes reflected from the human body that encode sub-mm displacements due to heart beats. We conducted a clinical study with both healthy participants and hospitalized cardiac patients with diverse structural and arrhythmic cardiac abnormalities including atrial fibrillation, flutter and congestive heart failure. Compared to electrocardiogram (ECG) data, our system computed R-R intervals for healthy participants with a median error of 28 ms over 12,280 heart beats and a correlation coefficient of 0.929. For hospitalized cardiac patients, the median error was 30 ms over 5639 heart beats with a correlation coefficient of 0.901. The increasing adoption of smart speakers in hospitals and homes may provide a means to realize the potential of our non-contact cardiac rhythm monitoring system for monitoring of contagious or quarantined patients, skin sensitive patients and in telemedicine settings.

     
    more » « less