Title: Refractive-type varifocal liquid-crystal Fresnel lenses for smart contacts
We demonstrate the implementation of a low-power, low-profile, varifocal liquid-crystal Fresnel lens stack suitable for tunable imaging in smart contact lenses. The lens stack consists of a high-order refractive-type liquid crystal Fresnel chamber, a voltage-controlled twisted nematic cell, a linear polarizer and a fixed offset lens. The lens stack has an aperture of 4 mm and thickness is ∼980 µm. The varifocal lens requires ∼2.5 VRMSfor a maximum optical power change of ∼6.5 D consuming electrical power of ∼2.6 µW. The maximum RMS wavefront aberration error was 0.2 µm and the chromatic aberration was 0.008 D/nm. The average BRISQUE image quality score of the Fresnel lens was 35.23 compared to 57.23 for a curved LC lens of comparable power indicating a superior Fresnel imaging quality.  more » « less
Award ID(s):
1932602
PAR ID:
10411751
Author(s) / Creator(s):
; ; ; ; ; ; ;
Publisher / Repository:
Optical Society of America
Date Published:
Journal Name:
Optics Express
Volume:
31
Issue:
10
ISSN:
1094-4087; OPEXFF
Format(s):
Medium: X Size: Article No. 17027
Size(s):
Article No. 17027
Sponsoring Org:
National Science Foundation
More Like this
  1. We demonstrate fabrication of tunable flexible refractive Fresnel liquid-crystal lens using PET for Smart Contact Lens System. We show focus tunability of 1.9D at 1.1VRMSusing voltage and pulse width modulation lens tuning techniques. 
    more » « less
  2. Abstract Open-channel microfluidics enables precise positioning and confinement of liquid volume to interface with tightly integrated optics, sensors, and circuit elements. Active actuation via electric fields can offer a reduced footprint compared to passive microfluidic ensembles and removes the burden of intricate mechanical assembly of enclosed systems. Typical systems actuate via manipulating surface wettability (i.e., electrowetting), which can render low-voltage but forfeits open-microchannel confinement. The dielectric polarization force is an alternative which can generate open liquid microchannels (sub-100 µm) but requires large operating voltages (50–200 VRMS) and low conductivity solutions. Here we show actuation of microchannels as narrow as 1 µm using voltages as low as 0.5 VRMSfor both deionized water and physiological buffer. This was achieved using resonant, nanoscale focusing of radio frequency power and an electrode geometry designed to abate surface tension. We demonstrate practical fluidic applications including open mixing, lateral-flow protein labeling, filtration, and viral transport for infrared biosensing—known to suffer strong absorption losses from enclosed channel material and water. This tube-free system is coupled with resonant wireless power transfer to remove all obstructing hardware — ideal for high-numerical-aperture microscopy. Wireless, smartphone-driven fluidics is presented to fully showcase the practical application of this technology. 
    more » « less
  3. Abstract Miniature lenses with a tunable focus are essential components for many modern applications involving compact optical systems. While several tunable lenses have been reported with various tuning mechanisms, they often face challenges with respect to power consumption, tuning speed, fabrication cost, or production scalability. In this work, we have adapted the mechanism of an Alvarez lens – a varifocal composite lens in which lateral shifts of two optical elements with cubic phase surfaces give rise to a change in the optical power – to construct a miniature, microelectromechanical system (MEMS)-actuated metasurface Alvarez lens. Implementation based on an electrostatic MEMS generates fast and controllable actuation with low power consumption. The utilization of metasurfaces – ultrathin and subwavelength-patterned diffractive optics – as optical elements greatly reduces the device volume compared to systems using conventional freeform lenses. The entire MEMS Alvarez metalens is fully compatible with modern semiconductor fabrication technologies, granting it the potential to be mass-produced at a low unit cost. In the reported prototype operating at 1550 nm wavelength, a total uniaxial displacement of 6.3 µm was achieved in the Alvarez metalens with a direct-current (DC) voltage application up to 20 V, which modulated the focal position within a total tuning range of 68 µm, producing more than an order of magnitude change in the focal length and a 1460-diopter change in the optical power. The MEMS Alvarez metalens has a robust design that can potentially generate a much larger tuning range without substantially increasing the device volume or energy consumption, making it desirable for a wide range of imaging and display applications. 
    more » « less
  4. Abstract One of the most significant developments in life sciences—the discovery of bacteria and protists—was accomplished by Antoni van Leeuwenhoek in the 17thcentury using a single ball lens microscope. It is shown that the full potential of single lens designs can be realized in a contact mode of imaging by ball lenses with a refractive index of n≈ 2, suitable for developing compact cellphone‐based microscopes. The quality of imaging is comparable to basic compound microscopes, but with a narrower field‐of‐view, and is demonstrated for various biomedical samples. The maximal magnification (M > 50) with the highest resolution (≈0.66 µm atλ= 589 nm) is achieved for imaging of nanoplasmonic structures by ball lenses made from LASFN35 glass, the index of which is tuned nearn =2 using chromatic dispersion. Due to limitations of geometrical optics, the imaging theory is developed based on an exact numerical solution of the Maxwell equations, including spherical aberration and the nearfield coupling of a point source. The modeling is performed using multiscale analysis: from the field propagation inside ball lenses with diameters 30 < D/λ < 4000 to the formation of the diffracted field at distances of ≈105λ. It is shown that such imaging enables the transition from pixel‐ to diffraction‐limited resolution in cellphone microscopy. 
    more » « less
  5. Abstract During drying, liquid‐applied particulate coatings develop stress and are consequently prone to stress‐induced defects, such as cracking, curling, and delamination. In this work, the stress development and cracking of coatings, prepared from aqueous silica and zinc oxide particle suspensions, were characterized using cantilever beam deflection with simultaneous imaging of the coating surface. Drying uniformity was improved and lateral or edge‐in drying was discouraged by using thin silicone walls around the perimeter of the cantilever. Coatings prepared from larger monodisperse silica particles (D50∼ 0.9 µm) dried uniformly but had a high critical cracking thickness (>150 µm) that prevented simultaneous study of stress development and cracking. Coatings prepared from smaller silica particles (D50∼ 0.3 µm) cracked readily at low thicknesses but exhibited edge‐in drying that complicated the stress measurement data. This drying nonuniformity was connected to the potential for these small particles to accumulate at the coating surface during drying. Hence, the selection of particle size and density was critical to drying uniformity when characterizing stress development and cracking. Coatings prepared from suspensions of zinc oxide particles (D50∼ 0.4 µm) were well‐suited for these studies, with uniform drying stress peaking at ∼1 MPa. Characteristic features in the stress development data above and below the critical cracking thickness (53 µm) were identified, demonstrating that cantilever beam deflection is a useful tool for studying the effectiveness of crack mitigation methods and the fundamentals of coating fracture during drying. 
    more » « less