Controllable deformation of liquid metal by electrocapillary actuation (ECA) is empirically characterized in fluidic channels at the sub-millimeter-length scale. In 100-µm-deep channels of varying widths, the Galinstan liquid metal could move at velocities of more than 40 mm/s. The liquid metal could extend more than 2.5 mm into the channels at an electrocapillary actuation voltage of 3 V DC. The dynamic behavior of the liquid metal as it moves in the microchannels is described. These results are useful for designing microsystems that use liquid metal as a functional material.
more »
« less
Open-channel microfluidics via resonant wireless power transfer
Abstract Open-channel microfluidics enables precise positioning and confinement of liquid volume to interface with tightly integrated optics, sensors, and circuit elements. Active actuation via electric fields can offer a reduced footprint compared to passive microfluidic ensembles and removes the burden of intricate mechanical assembly of enclosed systems. Typical systems actuate via manipulating surface wettability (i.e., electrowetting), which can render low-voltage but forfeits open-microchannel confinement. The dielectric polarization force is an alternative which can generate open liquid microchannels (sub-100 µm) but requires large operating voltages (50–200 VRMS) and low conductivity solutions. Here we show actuation of microchannels as narrow as 1 µm using voltages as low as 0.5 VRMSfor both deionized water and physiological buffer. This was achieved using resonant, nanoscale focusing of radio frequency power and an electrode geometry designed to abate surface tension. We demonstrate practical fluidic applications including open mixing, lateral-flow protein labeling, filtration, and viral transport for infrared biosensing—known to suffer strong absorption losses from enclosed channel material and water. This tube-free system is coupled with resonant wireless power transfer to remove all obstructing hardware — ideal for high-numerical-aperture microscopy. Wireless, smartphone-driven fluidics is presented to fully showcase the practical application of this technology.
more »
« less
- Award ID(s):
- 2011401
- PAR ID:
- 10365267
- Publisher / Repository:
- Nature Publishing Group
- Date Published:
- Journal Name:
- Nature Communications
- Volume:
- 13
- Issue:
- 1
- ISSN:
- 2041-1723
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Abstract Nearly all biosensing platforms can be described using two fundamental steps—collection and detection. Target analytes must be delivered to a sensing element, which can then relay the transduced signal. For point-of-care technologies, where operation is to be kept simple, typically the collection step is passive diffusion driven—which can be slow or limiting under low concentrations. This work demonstrates an integration of both active collection and detection by using resonant wireless power transfer coupled to a nanogap capacitor. Nanoparticles suspended in deionized water are actively trapped using wireless dielectrophoresis and positioned within the most sensitive fringe field regions for wireless impedance-based detection. Trapping of 40 nm particles and larger is demonstrated using a 3.5 VRMS, 1 MHz radiofrequency signal delivered over a distance greater than 8 cm from the nanogap capacitor. Wireless trapping and release of 1 µm polystyrene beads is simultaneously detected in real-time over a distance of 2.5 cm from the nanogap capacitor. Herein, geometric scaling strategies coupled with optimal circuit design is presented to motivate combined collection and detection biosensing platforms amenable to wireless and/or smartphone operation.more » « less
-
We demonstrate the implementation of a low-power, low-profile, varifocal liquid-crystal Fresnel lens stack suitable for tunable imaging in smart contact lenses. The lens stack consists of a high-order refractive-type liquid crystal Fresnel chamber, a voltage-controlled twisted nematic cell, a linear polarizer and a fixed offset lens. The lens stack has an aperture of 4 mm and thickness is ∼980 µm. The varifocal lens requires ∼2.5 VRMSfor a maximum optical power change of ∼6.5 D consuming electrical power of ∼2.6 µW. The maximum RMS wavefront aberration error was 0.2 µm and the chromatic aberration was 0.008 D/nm. The average BRISQUE image quality score of the Fresnel lens was 35.23 compared to 57.23 for a curved LC lens of comparable power indicating a superior Fresnel imaging quality.more » « less
-
Abstract Transversely curved composite shells of liquid crystal elastomer and polyethylene terephthalate with innervated electrodes present millisecond‐scale actuation with ≈200 mW electrical power inputs at low voltages (≈1 V). The molecular orientation is aligned to direct the thermomechanical work‐content to evert the native curvature. When powered, the curved structure initially remains latent and builds up strain energy. Thereafter, the work content is released in an ms‐scale impulse. The thin‐film actuators are powered against opposing loads to perform up to 10−5J of work. High speed imaging reveals tip velocities of several 100 mm s−1with powers approaching 10−4 J s−1. The design eschews bistability. After snap‐through, when the power is off, the actuator spontaneously resets to its native state. The actuation profiles are functions of the geometry and the electrical pulse patterns. The latency of actuation is reduced by powering the actuators with pulses that trigger snap‐through, allow its reset to the native state, but prevent its cooling to the ambient before subsequent actuation cycles. The actuation is harnessed in sub‐gram scale robots, including water‐strider mimicking configurations and steerable robots that can navigate on compliant (sand) and hard (slippery) surfaces. A viable template for impulsive actuation using frugal electrical power emerges.more » « less
-
Abstract Soft and miniaturized robots possess the capability to operate inside narrow, confined environments. However, powering soft robots inside these environments with on-board batteries or wired connections to external power supplies can significantly restrain their mobility. Similarly, wireless actuation approaches are constrained by near-field actuation, line-of-sight operation, or indiscriminate actuation of many actuators. To provide higher mobility for wireless soft robot to operate inside non-line-of-sight scenarios, we present a radio-frequency system that introduces frequency-selective actuation of liquid crystal elastomer actuators. We create liquid crystalline elastomer actuators with a low actuation temperature and embed them with conductive traces that resonate and heat by selected frequencies of radio-frequency excitation in the 2.40 GHz range. We further develop a wireless actuation platform that infers the wireless channel and beamforms towards the actuator to achieve efficient beamforming. Demonstrations show our system is capable of selectively actuating different actuators while the robot is in motion and obstructed by occlusions.more » « less