- Award ID(s):
- 2027367
- NSF-PAR ID:
- 10431770
- Date Published:
- Journal Name:
- Journal of Biomechanical Engineering
- Volume:
- 145
- Issue:
- 6
- ISSN:
- 0148-0731
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
Abstract Computational simulations of traumatic brain injury (TBI) are commonly used to advance understanding of the injury–pathology relationship, tissue damage thresholds, and design of protective equipment such as helmets. Both human and animal TBI models have developed substantially over recent decades, partially due to the inclusion of more detailed brain geometry and representation of tissues like cerebral blood vessels. Explicit incorporation of vessels dramatically affects local strain and enables researchers to investigate TBI-induced damage to the vasculature. While some studies have indicated that cerebral arteries are rate-dependent, no published experimentally based, rate-sensitive constitutive models of cerebral arteries exist. In this work, we characterize the mechanical properties of axially failed porcine arteries, both quasi-statically (0.01 s−1) and at high rate (>100 s−1), and propose a rate-sensitive model to fit the data. We find that the quasi-static and high-rate stress–stretch curves become significantly different (p < 0.05) above a stretch of 1.23. We additionally find a significant change in both failure stretch and stress as a result of strain rate. The stress–stretch curve is then modeled as a Holzapfel–Gasser–Ogden material, with a Prony series added to capture the effects of viscoelasticity. Ultimately, this paper demonstrates that rate dependence should be considered in the material properties of cerebral arteries undergoing high strain-rate deformations and provides a ready-to-use model for finite element implementation.more » « less
-
Accurate characterization of the mechanical properties of the human brain at both microscopic and macroscopic length scales is a critical requirement for modeling of traumatic brain injury and brain folding. To date, most experimental studies that employ classical tension/compression/shear tests report the mechanical properties of the brain averaged over both the gray and white matter within the macroscopic regions of interest. As a result, there is a missing correlation between the independent mechanical properties of the microscopic constituent elements and the composite bulk macroscopic mechanical properties of the tissue. This microstructural computational study aims to inversely predict the hyperelastic mechanical properties of the axonal fibers and their surrounding extracellular matrix (ECM) from the bulk tissue's mechanical properties. We develop a representative volume element (RVE) model of the bulk tissue consisting of axonal fibers and ECM with the embedded element technique. A multiobjective optimization technique is implemented to calibrate the model and establish the independent mechanical properties of axonal fibers and ECM based on seven previously reported experimental mechanical tests for bulk white matter tissue from the corpus callosum. The result of the study shows that the discrepancy between the reported values for the elastic behavior of white matter in literature stems from the anisotropy of the tissue at the microscale. The shear modulus of the axonal fiber is seven times larger than the ECM, with axonal fibers that also show greater nonlinearity, contrary to the common assumption that both components exhibit identical nonlinear characteristics. Statement of significance The reported mechanical properties of white matter microstructure used in traumatic brain injury or brain mechanics studies vary widely, in some cases by up to two orders of magnitude. Currently, the material parameters of the white matter microstructure are identified by a single loading mode or ultimately two modes of the bulk tissue. The presented material models only define the response of the bulk and homogenized white matter at a macroscopic scale and cannot explicitly capture the connection between the material properties of microstructure and bulk structure. To fill this knowledge gap, our study characterizes the hyperelastic material properties of axonal fibers and ECM using microscale computational modeling and multiobjective optimization. The hyperelastic material properties for axonal fibers and ECM presented in this study are more accurate than previously proposed because they have been optimized using seven or six loading modes of the bulk tissue, which were previously limited to only two of the seven possible loading modes. As such, the predicted values with high accuracy could be used in various computational modeling studies. The systematic characterization of the material properties of the human brain tissue at both macro- and microscales will lead to more accurate computational predictions, which will enable a better understanding of injury criteria, and has a positive impact on the improved development of smart protection systems, and more accurate prediction of brain development and disease progression.more » « less
-
Abstract A numerical and experimental hybrid approach is developed to study the constitutive behavior of the central nervous system white matter. A published transversely isotropic hyperelastic strain energy function is reviewed and used to determine stress–strain relationships for three idealized, simple loading scenarios. The proposed constitutive model is simplified to a three-parameter hyperelastic model by assuming the white matter's incompressibility. Due to a lack of experimental data in all three loading scenarios, a finite element model that accounts for microstructural axons and their kinematics is developed to simulate behaviors in simple shear loading scenarios to supplement existing uniaxial tensile test data. The parameters of the transversely isotropic hyperelastic material model are determined regressively using the hybrid data. The results highlight that a hybrid numerical virtual test coupled with experimental data, can determine the transversely isotropic hyperelastic model. It is noted that the model is not limited to small strains and can be applied to large deformations.more » « less
-
Abstract The ability to model physiological systems through 3D neural in-vitro systems may enable new treatments for various diseases while lowering the need for challenging animal and human testing. Creating such an environment, and even more impactful, one that mimics human brain tissue under mechanical stimulation, would be extremely useful to study a range of human-specific biological processes and conditions related to brain trauma. One approach is to use human cerebral organoids (hCOs) in-vitro models. hCOs recreate key cytoarchitectural features of the human brain, distinguishing themselves from more traditional 2D cultures and organ-on-a-chip models, as well as in-vivo animal models. Here, we propose a novel approach to emulate mild and moderate traumatic brain injury (TBI) using hCOs that undergo strain rates indicative of TBI. We subjected the hCOs to mild (2 s−1) and moderate (14 s−1) loading conditions, examined the mechanotransduction response, and investigated downstream genomic effects and regulatory pathways. The revealed pathways of note were cell death and metabolic and biosynthetic pathways implicating genes such as CARD9, ENO1, and FOXP3, respectively. Additionally, we show a steeper ascent in calcium signaling as we imposed higher loading conditions on the organoids. The elucidation of neural response to mechanical stimulation in reliable human cerebral organoid models gives insights into a better understanding of TBI in humans.
-
Abstract Purpose This study aimed to investigate the role of neck muscle activity and neck damping characteristics in traumatic brain injury (TBI) mechanisms.
Methods We used a previously validated head-neck finite element (FE) model that incorporates various components such as scalp, skull, cerebrospinal fluid, brain, muscles, ligaments, cervical vertebrae, and intervertebral discs. Impact scenarios included a Golf ball impact, NBDL linear acceleration, and Zhang’s linear and rotational accelerations. Three muscle activation strategies (no-activation, low-to-medium, and high activation levels) and two neck damping levels by perturbing intervertebral disc properties (high: hyper-viscoelastic and low: hyper-elastic) strategies were examined. We employed Head Injury Criterion (HIC), Brain Injury Criterion (BrIC), and maximum principal strain (MPS) as TBI measures.
Results Increased neck muscle activation consistently reduced the values of all TBI measures in Golf ball impact (HIC: 4%-7%, BrIC: 11%-25%, and MPS (occipital): 27%-50%) and NBDL study (HIC: 64%-69%, BrIC: 3%-9%, and MPS (occipital): 6%-19%) simulations. In Zhang’s study, TBI metric values decreased with the increased muscle activation from no-activation to low-to-medium (HIC: 74%-83%, BrIC: 27%-27%, and MPS (occipital): 60%-90%) and then drastically increased with further increases to the high activation level (HIC: 288%-507%, BrIC: 1%-25%, and MPS (occipital): 23%-305%). Neck damping changes from low to high decreased all values of TBI metrics, particularly in Zhang’s study (up to 40% reductions).
Conclusion Our results underscore the pivotal role of neck muscle activation and neck damping in TBI mitigation and holds promise to advance effective TBI prevention and protection strategies for diverse applications.