Title: Bidirectional Venturi Flowmeter Based on Capacitive Sensors for Spirometry
Abstract In this work, a portable venturi tube capable of measuring bidirectional respiratory flow is developed and correlated the measurements to pulmonary function. Pressure signals are transduced using flexible and compressible capacitive foam sensors embedded into the wall of the device. In this configuration, the sensors are able to provide differential pressure readings, from which the airflow rate passing through the tube could be extrapolated. Utilizing the venturi effect, the geometry of the spirometer tube is designed through finite element analysis to measure respiratory airflow during inhalation and exhalation. The device tube is 3D‐printed and used to measure tidal breathing and deep breathing, along with peak expiratory flow rates, on a healthy individual. This spirometer design allows for easy‐to‐use point‐of‐care diagnoses and has the potential to improve the care of respiratory illnesses.  more » « less
Award ID(s):
2223566 2054517
PAR ID:
10441336
Author(s) / Creator(s):
 ;  ;  ;  ;  ;  ;  ;  ;  ;  
Publisher / Repository:
Wiley Blackwell (John Wiley & Sons)
Date Published:
Journal Name:
Advanced Materials Technologies
Volume:
8
Issue:
18
ISSN:
2365-709X
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract Helical blood flow, characterized by its spiral motion, is a crucial physiological phenomenon observed in various circulatory structures, including the heart, aorta, vessel bifurcations, umbilical cord, and respiratory system. Despite its importance, a comprehensive understanding of helical flow dynamics is limited. This study aims to investigate the transition from laminar to turbulent flow in helical tubes under both steady and pulsatile conditions. An experimental setup was developed, featuring a closed-loop system with a pulsatile flow generator and steady pump, producing sinusoidal waveforms with adjustable frequencies and amplitudes. Five helical tube models, varying in curvature radius and torsion, were fabricated with a fixed inner diameter of 15 mm. High-frequency pressure transducers, ultrasonic flow sensors, and Laser Doppler Velocimetry (LDV) were employed to visualize flow fields and measure turbulence kinetic energy (TKE). Results indicate that helical tube geometry significantly impacts turbulence transitions. Specifically, larger curvature radii stabilize the flow and reduce turbulence downstream, while smaller radii lead to earlier transitions to turbulence. Under steady flow conditions, the critical Reynolds number (Re) for turbulence onset was found to be around 2300 upstream, similar to straight pipes, but significantly higher turbulence levels were observed downstream. Pulsatile flow with high pulsatility indices (PI > 3) near transitional Re markedly increases turbulence, particularly downstream, with large bursts of turbulence occurring during the deceleration phase. These findings enhance the understanding of helical flow dynamics and have implications for biomedical device design, diagnostics, and treatments for circulatory disorders. 
    more » « less
  2. The interactions between fluid flow and structural components of collapsible tubes are representative of those in several physiological systems. Although extensively studied, there exists a lack of characterization of the three-dimensionality in the structural deformations of the tube and its influence on the flow field. This experimental study investigates the spatio-temporal relationship between 3D tube geometry and the downstream flow field under conditions of fully open, closed, and slamming-type oscillating regimes. A methodology is implemented to simultaneously measure three-dimensional surface deformations in a collapsible tube and the corresponding downstream flow field. Stereophotogrammetry was used to measure tube deformations, and simultaneous flow field measurements included pressure and planar Particle Image Velocimetry (PIV) data downstream of the collapsible tube. The results indicate that the location of the largest collapse in the tube occurs close to the downstream end. In the oscillating regime, sections of the tube downstream of the largest mean collapse experience the largest oscillations in the entire tube that are completely coherent and in phase. At a certain streamwise distance upstream of the largest collapse, a switch in the direction of oscillations occurs with respect to those downstream. Physically, when the tube experiences constriction downstream of the location of the largest mean collapse, this causes the accumulation of fluid and build-up of pressure in the upstream regions and an expansion of these sections. Fluctuations in the downstream flow field are significantly influenced by tube fluctuations along the minor axes. The fluctuations in the downstream flowfield are influenced by the propagation of disturbances due to oscillations in tube geometry, through the advection of fluid through the tube. Further, the manifestation of the LU-type pressure fluctuations is found to be due to the variation in the propagation speed of the disturbances during the different stages within a period of oscillation of the tube. 
    more » « less
  3. Abstract Tracheal stenosis, a severe airway narrowing, poses significant challenges in respiratory function and often necessitates surgical intervention to restore proper airflow. This study aims to demonstrate how computational fluid dynamics (CFD) can provide a non-invasive, efficient, and highly individualized approach to assist surgeons in modeling and planning various surgical strategies for treatment. The CFD-based approach in this study provides significant advantages, including reduced time and cost, and the ability to analyze complex pulmonary airflow characteristics that are difficult to investigate using in vitro and in vivo studies. This research compares three tracheal geometries: a diseased airway with tracheal stenosis and two post-surgical configurations from different surgical plans. Simulations were conducted under four inhalation flow rates, i.e., rest (6 L/min), normal (30 L/min), moderate (60 L/min), and intensive exercise (120 L/min), to evaluate the impact of surgical outcomes on pulmonary airflow dynamics. The upper airway, modeled with a mouth inlet diameter of 20 mm, exhibited average velocities of 0.32, 1.59, 3.18, and 6.37 m/s, corresponding to the respective flow rates. The laminar model was used for the rest flow rate, while the shear stress transport (SST) k-ω model was applied to simulate turbulence with higher inhalation flow rates. The results revealed substantial improvements in flow parameters following surgery. The stenotic geometry exhibited extreme resistance, with pressure drops increasing from 1.96 Pa at rest to 318.9 Pa under intensive flow, and high wall shear stress (WSS) values peaking at 330.8 Pa. Surgical Plan 1 reduced pressure drops by up to 47% and WSS by 97%, while Surgical Plan 2 achieved even greater reductions, with pressure drops lowered by 45% and WSS reduced to 2.54 Pa under high flow rates. Localized flow disturbances, such as uneven airflow distribution among lung lobes, were also alleviated post-surgery. In the diseased airway, the right lower lobe received up to 40% of the total flow, causing severe imbalances. Surgical Plan 2 achieved the most uniform distribution, with all lobes receiving 13%-29% of airflow across all flow rates, ensuring effective oxygenation and minimizing risks of overdistension or under-perfusion. These findings suggest that the CFD-based approach employed in this study can effectively model surgical outcomes, providing surgeons with a fast, detailed, and non-invasive tool for tailoring procedures to individual patient needs. 
    more » « less
  4. null (Ed.)
    Breathing biomarkers, such as breathing rate, fractional inspiratory time, and inhalation-exhalation ratio, are vital for monitoring the user's health and well-being. Accurate estimation of such biomarkers requires breathing phase detection, i.e., inhalation and exhalation. However, traditional breathing phase monitoring relies on uncomfortable equipment, e.g., chestbands. Smartphone acoustic sensors have shown promising results for passive breathing monitoring during sleep or guided breathing. However, detecting breathing phases using acoustic data can be challenging for various reasons. One of the major obstacles is the complexity of annotating breathing sounds due to inaudible parts in regular breathing and background noises. This paper assesses the potential of using smartphone acoustic sensors for passive unguided breathing phase monitoring in a natural environment. We address the annotation challenges by developing a novel variant of the teacher-student training method for transferring knowledge from an inertial sensor to an acoustic sensor, eliminating the need for manual breathing sound annotation by fusing signal processing with deep learning techniques. We train and evaluate our model on the breathing data collected from 131 subjects, including healthy individuals and respiratory patients. Experimental results show that our model can detect breathing phases with 77.33% accuracy using acoustic sensors. We further present an example use-case of breathing phase-detection by first estimating the biomarkers from the estimated breathing phases and then using these biomarkers for pulmonary patient detection. Using the detected breathing phases, we can estimate fractional inspiratory time with 92.08% accuracy, the inhalation-exhalation ratio with 86.76% accuracy, and the breathing rate with 91.74% accuracy. Moreover, we can distinguish respiratory patients from healthy individuals with up to 76% accuracy. This paper is the first to show the feasibility of detecting regular breathing phases towards passively monitoring respiratory health and well-being using acoustic data captured by a smartphone. 
    more » « less
  5. In this work, we describe a benchtop model that recreates the motion and function of the diaphragm using a combination of advanced robotic and organic tissue. First, we build a high-fidelity anthropomorphic model of the diaphragm using thermoplastic and elastomeric material based on clinical imaging data. We then attach pneumatic artificial muscles to this elastomeric diaphragm, pre-programmed to move in a clinically relevant manner when pressurized. By inserting this diaphragm as the divider between two chambers in a benchtop model—one representing the thorax and the other the abdomen—and subsequently activating the diaphragm, we can recreate the pressure changes that cause lungs to inflate and deflate during regular breathing. Insertion of organic lungs in the thoracic cavity demonstrates this inflation and deflation in response to the pressures generated by our robotic diaphragm. By tailoring the input pressures and timing, we can represent different breathing motions and disease states. We instrument the model with multiple sensors to measure pressures, volumes, and flows and display these data in real-time, allowing the user to vary inputs such as the breathing rate and compliance of various components, and so they can observe and measure the downstream effect of changing these parameters. In this way, the model elucidates fundamental physiological concepts and can demonstrate pathology and the interplay of components of the respiratory system. This model will serve as an innovative and effective pedagogical tool for educating students on respiratory physiology and pathology in a user-controlled, interactive manner. It will also serve as an anatomically and physiologically accurate testbed for devices or pleural sealants that reside in the thoracic cavity, representing a vast improvement over existing models and ultimately reducing the requirement for testing these technologies in animal models. Finally, it will act as an impactful visualization tool for educating and engaging the broader community. 
    more » « less