Bioadhesive materials and patches are promising alternatives to surgical sutures and staples. However, many existing bioadhesives do not meet the functional requirements of current surgical procedures and interventions. Here, we present a translational patch material that exhibits instant adhesion to tissues (2.5-fold stronger than Tisseel, an FDA-approved fibrin glue), ultra-stretchability (stretching to >300% its original length without losing elasticity), compatibility with rapid photo-projection (<2 min fabrication time/patch), and ability to deliver therapeutics. Using our established procedures for the in silico design and optimization of anisotropic-auxetic patches, we created next-generation patches for instant attachment to tissues while conforming to a broad range of organ mechanics ex vivo and in vivo. Patches coated with extracellular vesicles derived from mesenchymal stem cells demonstrate robust wound healing capability in vivo without inducing a foreign body response and without the need for patch removal that can cause pain and bleeding. We further demonstrate a single material-based, void-filling auxetic patch designed for the treatment of lung puncture wounds.
For decades, bioadhesive materials have garnered great attention due to their potential to replace sutures and staples for sealing tissues during minimally invasive surgical procedures. However, the complexities of delivering bioadhesives through narrow spaces and achieving strong adhesion in fluid‐rich physiological environments continue to present substantial limitations to the surgical translation of existing sealants. In this work, a new strategy for minimally invasive tissue sealing based on a multilayer bioadhesive patch, which is designed to repel body fluids, to form fast, pressure‐triggered adhesion with wet tissues, and to resist biofouling and inflammation is introduced. The multifunctional patch is realized by a synergistic combination of three distinct functional layers: i) a microtextured bioadhesive layer, ii) a dynamic, blood‐repellent hydrophobic fluid layer, and iii) an antifouling zwitterionic nonadhesive layer. The patch is capable of forming robust adhesion to tissue surfaces in the presence of blood, and exhibits superior resistance to bacterial adhesion, fibrinogen adsorption, and in vivo fibrous capsule formation. By adopting origami‐based fabrication strategies, it is demonstrated that the patch can be readily integrated with a variety of minimally invasive end effectors to provide facile tissue sealing in ex vivo porcine models, offering new opportunities for minimally invasive tissue sealing in diverse clinical scenarios.
more » « less- Award ID(s):
- 1935291
- NSF-PAR ID:
- 10452205
- Publisher / Repository:
- Wiley Blackwell (John Wiley & Sons)
- Date Published:
- Journal Name:
- Advanced Materials
- Volume:
- 33
- Issue:
- 11
- ISSN:
- 0935-9648
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
Abstract -
Modern diagnostics is pivoting towards less invasive health monitoring in dermal interstitial fluid, rather than blood or urine. However, the skin’s outermost layer, the stratum corneum, makes accessing the fluid more difficult without invasive, needle-based technology. Simple, minimally invasive means for surpassing this hurdle are needed. Methods: To address this problem, a flexible, Band-Aid-like patch for sampling interstitial fluid was developed and tested. This patch uses simple resistive heating elements to thermally porate the stratum corneum, allowing the fluid to exude from the deeper skin tissue without applying external pressure. Fluid is then transported to an on-patch reservoir through selfdriving hydrophilic microfluidic channels. Results: Testing with living, ex-vivo human skin models demonstrated the device’s ability to rapidly collect sufficient interstitial fluid for biomarker quantification. Further, finite-element modeling showed that the patch can porate the stratum corneum without raising the skin’s temperature to paininducing levels in the nerve-laden dermis. Conclusion: Relying only on simple, commercially scalable fabrication methods, this patch outperforms the collection rate of various microneedle-based patches, painlessly sampling a human bodily fluid without entering the body. Significance: The technology holds potential as a clinical device for an array of biomedical applications, especially with the integration of on-patch testing.more » « less
-
Bioadhesives such as tissue adhesives, hemostatic agents, and tissue sealants have potential advantages over sutures and staples for wound closure, hemostasis, and integration of implantable devices onto wet tissues. However, existing bioadhesives display several limitations including slow adhesion formation, weak bonding, low biocompatibility, poor mechanical match with tissues, and/or lack of triggerable benign detachment. Here, we report a bioadhesive that can form instant tough adhesion on various wet dynamic tissues and can be benignly detached from the adhered tissues on demand with a biocompatible triggering solution. The adhesion of the bioadhesive relies on the removal of interfacial water from the tissue surface, followed by physical and covalent cross-linking with the tissue surface. The triggerable detachment of the bioadhesive results from the cleavage of bioadhesive’s cross-links with the tissue surface by the triggering solution. After it is adhered to wet tissues, the bioadhesive becomes a tough hydrogel with mechanical compliance and stretchability comparable with those of soft tissues. We validate in vivo biocompatibility of the bioadhesive and the triggering solution in a rat model and demonstrate potential applications of the bioadhesive with triggerable benign detachment in ex vivo porcine models.
-
Abstract Interstitial fluid (ISF) that surrounds cells in tissues of the body is a novel source of biomarker that complements conventional sources like blood, urine, and saliva. To overcome difficulties in harvesting ISF, a minimally invasive, rapid, simple‐to‐use, cost‐effective method is developed to collect ISF from the skin involving a microneedle (MN) patch. By pressing 650 µm long MNs at an angle just below the skin surface, blood‐free ISF flows through micropores to the skin surface and is absorbed into a thin strip of paper on the MN patch backing for subsequent analysis. An optimized method in rat skin in vivo is well tolerated and able to collect >2 µL of ISF within 1 min. Brief skin pretreatment with MNs followed by a 5 min delay dramatically increases subsequent ISF collection by a mechanism believed to involve increased skin hydration. ISF collection using an MN patch has the potential to simplify access to biomarkers in ISF for research and future medical diagnostic and monitoring applications.
-
The use of bioelectronic devices relies on direct contact with soft biotissues. For transistor-type bioelectronic devices, the semiconductors that need to have direct interfacing with biotissues for effective signal transduction do not adhere well with wet tissues, thereby limiting the stability and conformability at the interface. We report a bioadhesive polymer semiconductor through a double-network structure formed by a bioadhesive brush polymer and a redox-active semiconducting polymer. The resulting semiconducting film can form rapid and strong adhesion with wet tissue surfaces together with high charge-carrier mobility of ~1 square centimeter per volt per second, high stretchability, and good biocompatibility. Further fabrication of a fully bioadhesive transistor sensor enabled us to produce high-quality and stable electrophysiological recordings on an isolated rat heart and in vivo rat muscles.