Color centers in wide bandgap semiconductors are attracting broad attention for use as platforms for quantum technologies relying on room-temperature single-photon emission (SPE), and for nanoscale metrology applications building on the centers’ response to electric and magnetic fields. Here, we demonstrate room-temperature SPE from defects in cubic boron nitride (cBN) nanocrystals, which we unambiguously assign to the cubic phase using spectrally resolved Raman imaging. These isolated spots show photoluminescence (PL) spectra with zero-phonon lines (ZPLs) within the visible region (496–700 nm) when subject to sub-bandgap laser excitation. Second-order autocorrelation of the emitted photons reveals antibunching withg2(0) ∼ 0.2, and a decay constant of 2.75 ns that is further confirmed through fluorescence lifetime measurements. The results presented herein prove the existence of optically addressable isolated quantum emitters originating from defects in cBN, making this material an interesting platform for opto-electronic devices and quantum applications.
more »
« less
Quantum approach for nanoparticle fluorescence by sub‐ns photon detection
Abstract Well defined detection and analysis of nanoparticle‐sized samples such as extracellular vesicles or viruses may be important for potential disease diagnostics. However, using conventional flow‐cytometry optical methods to evaluate such small particles is quite challenging. The reason is that the particle is smaller than the diffraction limit, making detection difficult. An alternative approach is fluorescence detection via conjugated fluorochromes attached to the nanoparticles; the challenge in this case is the limitation imposed upon detection of a very small number of emitted photons buried in high background photon counts. Emitted fluorescence is described by the well‐known equation kf = σa I Q, which describes the emitted fluorescence rate (kf) (photons/s) as the multiplication of molecular absorption cross section(σa), excitation intensity (I), and quantum yield (Q). In addition, the excitation rate is equal to 1/t, which is the inverse of the lifetime of several ns representing the most typical conjugated fluorescent molecules used in flow cytometry. We recently developed a sub‐ns photon sensor that is faster than most fluorescence lifetimes, since sub‐ns speed is a critically important parameter for the separation of individual emitted photons. Based on our observation of fluorescence and background levels on typical commercial flow cytometers it is evident that a significant component of the background is induced by water‐molecular vibrations. Therefore, understanding what constitutes all the components that contribute to the signals we measure in flow cytometry would help in defining what we currently call “background signals.” We attempted to define a theoretical model to try to unravel these issues. This model was based on use of a reflective dry surface in the absence of water molecules. Our objective was to determine if it is possible to minimize background and enhance signal, and to provide valuable information on the contributing components of the signals collected. In order to test this model, we tested a single dried particle 50 nm in diameter on a reflective surface with minimum background. While this is clearly not a standard biological system, our results suggest that this quantum approach closely follows established photon base theory. Our goal was to define the parameters for practical nanoparticle‐fluorescence analysis while enhancing our knowledge of the contribution of background properties.
more »
« less
- Award ID(s):
- 2013940
- PAR ID:
- 10453465
- Publisher / Repository:
- Wiley Blackwell (John Wiley & Sons)
- Date Published:
- Journal Name:
- Cytometry Part A
- Volume:
- 99
- Issue:
- 2
- ISSN:
- 1552-4922
- Page Range / eLocation ID:
- p. 145-151
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Abstract Circulating tumor cell clusters (CTCCs) are rare cellular events found in the blood stream of metastatic tumor patients. Despite their scarcity, they represent an increased risk for metastasis. Label-free detection methods of these events remain primarily limited to in vitro microfluidic platforms. Here, we expand on the use of confocal backscatter and fluorescence flow cytometry (BSFC) for label-free detection of CTCCs in whole blood using machine learning for peak detection/classification. BSFC uses a custom-built flow cytometer with three excitation wavelengths (405 nm, 488 nm, and 633 nm) and five detectors to detect CTCCs in whole blood based on corresponding scattering and fluorescence signals. In this study, detection of CTCC-associated GFP fluorescence is used as the ground truth to assess the accuracy of endogenous back-scattered light-based CTCC detection in whole blood. Using a machine learning model for peak detection/classification, we demonstrated that the combined use of backscattered signals at the three wavelengths enable detection of ~ 93% of all CTCCs larger than two cells with a purity of > 82% and an overall accuracy of > 95%. The high level of performance established through BSFC and machine learning demonstrates the potential for label-free detection and monitoring of CTCCs in whole blood. Further developments of label-free BSFC to enhance throughput could lead to important applications in the isolation of CTCCs in whole blood with minimal disruption and ultimately their detection in vivo.more » « less
-
Diagnostic assays utilizing fluorescent reporters in the context of low abundance biomarkers for cancer and infectious disease can reach lower limits of detection through efficient collection of emitted photons into an optical sensor. In this work, we present the rational design, fabrication, and application of one-dimensional photonic crystal (PC) grating interfaces to accomplish a cost-effective prism-free, metal-free, and objective-free platform for augmentation of fluorescence emission collection efficiency. Guided mode resonance (GMR) of the PC is engineered to match the laser excitation (532 nm) and emission maximum (580 nm) of the radiating dipoles to arrive at optimized conditions. The photo-plasmonic hybrid nano-engineering using silver nanoparticles presented >110-fold steering fluorescence enhancement enabling placement of the sample between the excitation source and detector that are in a straight line. From the experimental and simulation inferences, we propose a radiating GMR model by scrutinizing the polarized emission properties of the hybrid substrate, in accordance with the radiating plasmon model. The augmented fluorescence intensity realized here with a simple detection instrument provides sub-nanomolar sensitivity to provide a path toward point-of-care scenarios.more » « less
-
In this Letter a novel, to our knowledge, approach for near-infrared (NIR) fluorescence portable confocal microscopy is introduced, aiming to enhance fluorescence imaging of biological samples in the NIR-II window. By integrating a superconducting nanowire single-photon detector (SNSPD) into a confocal microscopy, we have significantly leveraged the detection efficiency of the NIR-II fluorescence signal from indocyanine green (ICG), an FDA-approved dye known for its NIR-II fluorescence capabilities. The SNSPD, characterized by its extremely low dark count rate and optimized NIR system detection efficiency, enables the excitation of ICG with 1 mW and the capture of low-light fluorescence signals from deep regions (up to 512 µm). Consequently, our technique was able to produce high-resolution images of bio samples with a superior signal-to-noise ratio, making a substantial advancement in the field of fluorescence microscopy and offering a promising opportunity for future clinical study.more » « less
-
Optical projection tomography (OPT) is a powerful imaging modality for attaining high resolution absorption and fluorescence imaging in tissue samples and embryos with a diameter of roughly 1 mm. Moving past this 1 mm limit, scattered light becomes the dominant fraction detected, adding significant “blur” to OPT. Time-domain OPT has been used to select out early-arriving photons that have taken a more direct route through the tissue to reduce detection of scattered photons in these larger samples, which are the cause of image domain blur1. In addition, it was recently demonstrated by our group that detection of scattered photons could be further depressed by running in a “deadtime” regime where laser repetition rates are selected such that the deadtime incurred by early-arriving photons acts as a shutter to later-arriving scattered photons2. By running in this deadtime regime, far greater early photon count rates are achievable than with standard early photon OPT. In this work, another advantage of this enhanced early photon collection approach is demonstrated: specifically, a significant improvement in signal-to-noise ratio. In single photon counting detectors, the main source of noise is “afterpulsing,” which is essentially leftover charge from a detected photon that spuriously results in a second photon count. When the arrival of the photons are time-stamped by the time correlated single photon counting (TCSPC) module , the rate constant governing afterpusling is slow compared to the time-scale of the light pulse detected so it is observed as a background signal with very little time-correlation. This signal is present in all time-gates and so adds noise to the detection of early photons. However, since the afterpusling signal is proportional to the total rate of photon detection, our enhanced early photon approach is uniquely able to have increased early photon counts with no appreciable increase in the afterpulsing since overall count-rate does not change. This is because as the rate of early photon detection goes up, the rate of late-photon detection reduces commensurately, yielding no net change in the overall rate of photons detected. This hypothesis was tested on a 4 mm diameter tissue-mimicking phantom (μa = 0.02 mm-1, μs’ = 1 mm-1) by ranging the power of a 10 MHz pulse 780-nm laser with pulse spread of < 100 fs (Calmar, USA) and an avalanche photodiode (MPD, Picoquant, Germany) and TCSPC module (HydraHarp, Picoquant, Germany) for light detection. Details of the results are in Fig. 1a, but of note is that we observed more than a 60-times improvement in SNR compared to conventional early photon detection that would have taken 1000-times longer to achieve the same early photon count. A demonstration of the type of resolution possible is in Fig 1b with an image of a 4-mm-thick human breast cancer biopsy where tumor spiculations of less than 100 μm diameter are observable. 1Fieramonti, L. et al. PloS one (2012). 2Sinha, L., et al. Optics letters (2016).more » « less
An official website of the United States government
