Title: Early photon optical tomography signal-to-noise ratio improved by almost two orders-of-magnitude by running in the “deadtime” regime
Optical projection tomography (OPT) is a powerful imaging modality for attaining high resolution absorption and fluorescence imaging in tissue samples and embryos with a diameter of roughly 1 mm. Moving past this 1 mm limit, scattered light becomes the dominant fraction detected, adding significant “blur” to OPT. Time-domain OPT has been used to select out early-arriving photons that have taken a more direct route through the tissue to reduce detection of scattered photons in these larger samples, which are the cause of image domain blur1. In addition, it was recently demonstrated by our group that detection of scattered photons could be further depressed by running in a “deadtime” regime where laser repetition rates are selected such that the deadtime incurred by early-arriving photons acts as a shutter to later-arriving scattered photons2. By running in this deadtime regime, far greater early photon count rates are achievable than with standard early photon OPT. In this work, another advantage of this enhanced early photon collection approach is demonstrated: specifically, a significant improvement in signal-to-noise ratio. In single photon counting detectors, the main source of noise is “afterpulsing,” which is essentially leftover charge from a detected photon that spuriously results in a second photon count. more » When the arrival of the photons are time-stamped by the time correlated single photon counting (TCSPC) module , the rate constant governing afterpusling is slow compared to the time-scale of the light pulse detected so it is observed as a background signal with very little time-correlation. This signal is present in all time-gates and so adds noise to the detection of early photons. However, since the afterpusling signal is proportional to the total rate of photon detection, our enhanced early photon approach is uniquely able to have increased early photon counts with no appreciable increase in the afterpulsing since overall count-rate does not change. This is because as the rate of early photon detection goes up, the rate of late-photon detection reduces commensurately, yielding no net change in the overall rate of photons detected. This hypothesis was tested on a 4 mm diameter tissue-mimicking phantom (μa = 0.02 mm-1, μs’ = 1 mm-1) by ranging the power of a 10 MHz pulse 780-nm laser with pulse spread of < 100 fs (Calmar, USA) and an avalanche photodiode (MPD, Picoquant, Germany) and TCSPC module (HydraHarp, Picoquant, Germany) for light detection. Details of the results are in Fig. 1a, but of note is that we observed more than a 60-times improvement in SNR compared to conventional early photon detection that would have taken 1000-times longer to achieve the same early photon count. A demonstration of the type of resolution possible is in Fig 1b with an image of a 4-mm-thick human breast cancer biopsy where tumor spiculations of less than 100 μm diameter are observable. 1Fieramonti, L. et al. PloS one (2012). 2Sinha, L., et al. Optics letters (2016). « less
Authors:
; ; ;
Award ID(s):
1653627
Publication Date:
NSF-PAR ID:
10046223
Journal Name:
World Molecular Imaging Congress 2017
Sponsoring Org:
National Science Foundation
More Like this
  1. Time-frequency (TF) filtering of analog signals has played a crucial role in the development of radio-frequency communications and is currently being recognized as an essential capability for communications, both classical and quantum, in the optical frequency domain. How best to design optical time-frequency (TF) filters to pass a targeted temporal mode (TM), and to reject background (noise) photons in the TF detection window? The solution for ‘coherent’ TF filtering is known—the quantum pulse gate—whereas the conventional, more common method is implemented by a sequence of incoherent spectral filtering and temporal gating operations. To compare these two methods, we derive a general formalism for two-stage incoherent time-frequency filtering, finding expressions for signal pulse transmission efficiency, and for the ability to discriminate TMs, which allows the blocking of unwanted background light. We derive the tradeoff between efficiency and TM discrimination ability, and find a remarkably concise relation between these two quantities and the time-bandwidth product of the combined filters. We apply the formalism to two examples—rectangular filters or Gaussian filters—both of which have known orthogonal-function decompositions. The formalism can be applied to any state of light occupying the input temporal mode, e.g., ‘classical’ coherent-state signals or pulsed single-photon states of light. Inmore »contrast to the radio-frequency domain, where coherent detection is standard and one can use coherent matched filtering to reject noise, in the optical domain direct detection is optimal in a number of scenarios where the signal flux is extremely small. Our analysis shows how the insertion loss and SNR change when one uses incoherent optical filters to reject background noise, followed by direct detection, e.g. photon counting. We point out implications in classical and quantum optical communications. As an example, we study quantum key distribution, wherein strong rejection of background noise is necessary to maintain a high quality of entanglement, while high signal transmission is needed to ensure a useful key generation rate.

    « less
  2. Abstract
    Excessive phosphorus (P) applications to croplands can contribute to eutrophication of surface waters through surface runoff and subsurface (leaching) losses. We analyzed leaching losses of total dissolved P (TDP) from no-till corn, hybrid poplar (Populus nigra X P. maximowiczii), switchgrass (Panicum virgatum), miscanthus (Miscanthus giganteus), native grasses, and restored prairie, all planted in 2008 on former cropland in Michigan, USA. All crops except corn (13 kg P ha−1 year−1) were grown without P fertilization. Biomass was harvested at the end of each growing season except for poplar. Soil water at 1.2 m depth was sampled weekly to biweekly for TDP determination during March–November 2009–2016 using tension lysimeters. Soil test P (0–25 cm depth) was measured every autumn. Soil water TDP concentrations were usually below levels where eutrophication of surface waters is frequently observed (&gt; 0.02 mg L−1) but often higher than in deep groundwater or nearby streams and lakes. Rates of P leaching, estimated from measured concentrations and modeled drainage, did not differ statistically among cropping systems across years; 7-year cropping system means ranged from 0.035 to 0.072 kg P ha−1 year−1 with large interannual variation. Leached P was positively related to STP, which decreased over the 7 years in all systems. These results indicate that both P-fertilized and unfertilized cropping systems mayMore>>
  3. In time-correlated single-photon counting (TCSPC), photons that arrive during the detector and timing electronics dead times are missed, causing distortion of the detection time distribution. Conventional wisdom holds that TCSPC should be performed with detections in fewer than 5% of illumination cycles to avoid substantial distortion. This requires attenuation and leads to longer acquisition times if the incident flux is too high. Through the example of ranging with a single-photon lidar system, this work demonstrates that accurately modeling the sequence of detection times as a Markov chain allows for measurements at much higher incident flux without attenuation. Our probabilistic model is validated by the close match between the limiting distribution of the Markov chain and both simulated and experimental data, so long as issues of calibration and afterpulsing are minimal. We propose an algorithm that corrects for the distortion in detection histograms caused by dead times without assumptions on the form of the transient light intensity. Our histogram correction yields substantially improved depth imaging performance, and modest additional improvement is achieved with a parametric model assuming a single depth per pixel. We show results for depth and flux estimation with up to 5 photoelectrons per illumination cycle on average, facilitatingmore »an increase in time efficiency of more than two orders of magnitude. The use of identical TCSPC equipment in other fields suggests that our modeling and histogram correction could likewise enable high-flux acquisitions in fluorescence lifetime microscopy or quantum optics applications.

    « less
  4. Time-correlated single-photon counting (TCSPC) is an enabling technology for applications such as low-light fluorescence lifetime microscopy and photon counting time-of-flight (ToF) 3D imaging. However, state-of-the-art TCSPC single-photon timing resolution (SPTR) is limited to 3–100 ps by single-photon detectors. Here, we experimentally demonstrate a time-magnified TCSPC (TM-TCSPC) that achieves an ultrashort SPTR of 550 fs with an off-the-shelf single-photon detector. The TM-TCSPC can resolve ultrashort pulses with a 130-fs pulse width difference at a 22-fs accuracy. When applied to photon counting ToF 3D imaging, the TM-TCSPC greatly suppresses the range walk error that limits all photon counting ToF 3D imaging systems by 99.2% and thus provides high depth accuracy and precision of 26 µm and 3 µm, respectively.

  5. 1300 nm three-photon calcium imaging has emerged as a useful technique to allow calcium imaging in deep brain regions. Application to large-scale neural activity imaging entails a careful balance between recording fidelity and perturbation to the sample. We calculated and experimentally verified the excitation pulse energy to achieve the minimum photon count required for the detection of calcium transients in GCaMP6s-expressing neurons for 920 nm two-photon and 1320 nm three-photon excitation. By considering the combined effects of in-focus signal attenuation and out-of-focus background generation, we quantified the cross-over depth beyond which three-photon microscopy outpeforms two-photon microscopy in recording fidelity. Brain tissue heating by continuous three-photon imaging was simulated with Monte Carlo method and experimentally validated with immunohistochemistry. Increased immunoreactivity was observed with 150 mW excitation power at 1 and 1.2 mm imaging depths. Our analysis presents a translatable model for the optimization of three-photon calcium imaging based on experimentally tractable parameters.