We examined the effect of estimation methods, maximum likelihood (ML), unweighted least squares (ULS), and diagonally weighted least squares (DWLS), on three population SEM (structural equation modeling) fit indices: the root mean square error of approximation (RMSEA), the comparative fit index (CFI), and the standardized root mean square residual (SRMR). We considered different types and levels of misspecification in factor analysis models: misspecified dimensionality, omitting cross-loadings, and ignoring residual correlations. Estimation methods had substantial impacts on the RMSEA and CFI so that different cutoff values need to be employed for different estimators. In contrast, SRMR is robust to the method used to estimate the model parameters. The same criterion can be applied at the population level when using the SRMR to evaluate model fit, regardless of the choice of estimation method.
more »
« less
High‐resolution peak analysis in TOF SIMS data
High mass resolution time‐of‐flight secondary ion mass spectrometry (TOF SIMS) can provide a wealth of chemical information about a sample, but the analysis of such data is complicated by detector dead‐time effects that lead to systematic shifts in peak shapes, positions, and intensities. We introduce a new maximum‐likelihood analysis that incorporates the detector behavior in the likelihood function, such that a parametric spectrum model can be fit directly to as‐measured data. In numerical testing, this approach is shown to be the most precise and lowest‐bias option when compared with both weighted and unweighted least‐squares fitting of data corrected for dead‐time effects. Unweighted least‐squares analysis is the next best, while weighted least‐squares suffers from significant bias when the number of pulses used is small. We also provide best‐case estimates of the achievable precision in fitting TOF SIMS peak positions and intensities and investigate the biases introduced by ignoring background intensity and by fitting to just the intense part of a peak. We apply the maximum‐likelihood method to fit two experimental data sets: a positive‐ion spectrum from a multilayer MoS2sample and a positive‐ion spectrum from a TiZrNi bulk metallic glass sample. The precision of extracted isotope masses and relative abundances obtained is close to the best‐case predictions from the numerical simulations despite the use of inexact peak shape functions and other approximations. Implications for instrument calibration, incorporation of prior information about the sample, and extension of this approach to the analysis of imaging data are also discussed.
more »
« less
- Award ID(s):
- 1709667
- PAR ID:
- 10455716
- Publisher / Repository:
- Wiley Blackwell (John Wiley & Sons)
- Date Published:
- Journal Name:
- Surface and Interface Analysis
- Volume:
- 53
- Issue:
- 1
- ISSN:
- 0142-2421
- Format(s):
- Medium: X Size: p. 53-67
- Size(s):
- p. 53-67
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Time-of-flight secondary ion mass spectrometry (ToF-SIMS) is used for chemical analysis of surfaces. ToF-SIMS is a powerful tool for polymer science because it detects a broad mass range with good mass resolution, thereby distinguishing between polymers that have similar elemental compositions and/or the same types of functional groups. Chemical labeling techniques that enhance contrast, such as deuterating or staining one constituent, are generally unnecessary. ToF-SIMS can generate both two-dimensional images and three-dimensional depth profiles, where each pixel in an image is associated with a complete mass spectrum. This Review begins by introducing the principles of ToF-SIMS measurements, including instrumentation, modes of operation, strategies for data analysis, and strengths/limitations when characterizing polymer surfaces. The sections that follow describe applications in polymer science that benefit from characterization by ToF-SIMS, including thin films and coatings, polymer blends, composites, and electronic materials. The examples selected for discussion showcase the three standard modes of operation (spectral analysis, imaging, and depth profiling) and highlight practical considerations that relate to experimental design and data processing. We conclude with brief comments about broader opportunities for ToF-SIMS in polymer science.more » « less
-
Abstract Time-of-flight secondary ion mass spectrometry (ToF-SIMS) is a versatile surface-sensitive technique for characterizing both hard and soft matter. Its chemical and molecular specificity, high spatial resolution, and superior sensitivity make it an ideal method for depth profiling polymeric systems, including those comprised of both inorganic and organic constituents (i.e., polymer nanocomposites, PNCs). To best utilize ToF-SIMS for characterizing PNCs, experimental conditions must be optimized to minimize challenges such as the matrix effect and charge accumulation. Toward that end, we have successfully used ToF-SIMS with a Xe+ focused ion beam to depth profile silica nanoparticles grafted with poly(methyl methacrylate) (PMMA-NP) in a poly(styrene-ran-acrylonitrile) matrix film by selecting conditions that address charge compensation and the primary incident beam angles. By tracking the sputtered Si+ species and fitting the resultant concentration profile, the diffusion coefficient of PMMA-NP was determined to be D = 2.4 × 10−14 cm2/s. This value of D lies between that measured using Rutherford backscattering spectrometry (6.4 × 10−14 cm2/s) and the value predicted by the Stokes–Einstein model (2.5 × 10−15 cm2/s). With carefully tuned experimental parameters, ToF-SIMS holds great potential for quantitatively characterizing the nanoparticles at the surfaces and interfaces within PNC materials as well as soft matter in general.more » « less
-
null (Ed.)We study how several published baryonic Tully-Fisher relations (BTFRs) fit a large sample of galaxies from the Arecibo legacy fast ALFA (ALFALFA) 21cm survey to determine which BTFR is a better template for calculating the distances and peculiar velocities of the ALFALFA galaxies. In particular, the BTFRs studied were those published by Papastergis et al. (2016) and Lelli et al. (2019). To do so, we first derived the rotational velocities and baryonic masses of a sub sample of galaxies with ”good” data, which make up 68% of the ALFALFA galaxies. We then calculated the best-fit line of the sample using fivedifferent fitting methods: (1) the ordinary least squares (OLS), (2) the maximum likelihood method assuming no intrinsic scatter as defined by Papastergis et al. (2016), (3) the maximum likelihood method with intrinsic scatter along the perpendicular direction (σ⊥,intr) also defined by Papastergis et al. (2016), (4) the maximum likelihood method assuming intrinsic scatter along the vertical direction (σy) as defined by Lelli et al. (2019)., and (5) the maximum likelihood method with intrinsic scatter along the perpendicular direction (σ⊥) also defined by Lelli et al. (2019). We find that fitting method (2) yields the steepest slope, 3.42, which agrees well with the values obtained in previous studies. We use this fit-line to compare with the two published BTFRs and determine that the BTFR derived by Papastergis et al.(2016) is the better template for calculating the distances and pecu-liar velocities of the ALFALFA catalog. This work was supported by NSF/AST-1714828 and by grants from the Brinson Foundation.more » « less
-
Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) is a powerful technique for elemental compositional analysis and depth profiling of materials. However, it encounters the problem of matrix effects that hinder its application. In this work, we introduce a pioneering ToF-SIMS calibration method tailored for SixGeySnz ternary alloys. SixGe1-x and Ge1-zSnz binary alloys with known compositions are used as calibration reference samples. Through a systematic SIMS quantification study of SiGe and GeSn binary alloys, we unveil a linear correlation between secondary ion intensity ratio and composition ratio for both SiGe and GeSn binary alloys, effectively mitigating the matrix effects. Extracted relative sensitivity factor (RSF) value from SixGe1-x (0.07<0.83) and Ge1-zSnz (0.066<0.183) binary alloys are subsequently applied to those of SixGeySnz (0.011<0.113, 0.863<0.935 and 0.023<0.103) ternary alloys for elemental compositions quantification. These values are cross-checked by Atom Probe Tomography (APT) analysis, an indication of the great accuracy and reliability of as-developed ToF-SIMS calibration process. The proposed method and its reference sample selection strategy in this work provide a low-cost as well as simple-to-follow calibration route for SiGeSn composition analysis, thus driving the development of next-generation multifunctional SiGeSn-related semiconductor devices.more » « less
An official website of the United States government