skip to main content


Title: Supramolecular Recognition‐Mediated Layer‐by‐Layer Self‐Assembled Gold Nanoparticles for Customized Sensitivity in Paper‐Based Strip Nanobiosensors
Abstract

Herein, a smart supramolecular self‐assembly‐mediated signal amplification strategy is developed on a paper‐based nanobiosensor to achieve the sensitive and customized detection of biomarkers. The host–guest recognition between β‐cyclodextrin‐coated gold nanoparticles (AuNPs) and 1‐adamantane acetic acid or tetrakis(4‐carboxyphenyl)porphyrin is designed and applied to the layer‐by‐layer self‐assembly of AuNPs at the test area of the strip. Thus, the amplified platform exhibits a high sensitivity with a detection limit at subattogram levels (approximately dozens of molecules per strip) and a wide dynamic range of concentration over seven orders of magnitude. The applicability and universality of this sensitive platform are demonstrated in clinically significant ranges to measure carcinoembryonic antigen and HIV‐1 capsid p24 antigen in spiked serum and clinical samples. The customized biomarker detection ability for the on‐demand needs of clinicians is further verified through cycle incubation‐mediated controllable self‐assembly. Collectively, the supramolecular self‐assembly amplification method is suitable as a universal point‐of‐care diagnostic tool and can be readily adapted as a platform technology for the sensitive assay of many different target analytes.

 
more » « less
NSF-PAR ID:
10456123
Author(s) / Creator(s):
 ;  ;  ;  ;  ;  ;  ;  
Publisher / Repository:
Wiley Blackwell (John Wiley & Sons)
Date Published:
Journal Name:
Small
Volume:
15
Issue:
51
ISSN:
1613-6810
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract

    The SARS‐CoV‐2 pandemic caused a public health crisis throughout the world and highlighted the need for rapid and sensitive testing as a countermeasure. A sensitive and specific biosensor platform is developed for the detection of antigen and RNA of SARS‐CoV‐2, and its variant (B1.1.529). The demonstrated biosensor platform combines unique protein catalyzed capture bioreceptors (PCCs) for antigen capture and a chimeric (RNA‐DNA) probe for RNA detection using LwaCas13a collateral cleavage activity atop graphene field effect transistors (gFETs). The reported biosensor is able to differentiate unprocessed 104pfu m−1samples of SARS‐CoV‐2 from Influenza and Rhinovirus. The limit of detection (LOD) calculated for SARS‐CoV‐2 antigen is 103in buffer and 104PFU mL−1in 10% saliva, while LOD of ≈65 amcalculated for viral RNA isolate without amplification. To provide a high reliability of detection, the role of internal and external factors with respect to gate voltage is further analyzed by Principal Component Analysis (PCA). Based on PCA analysis, the authors are able to classify the samples as pathogen positive or negative (Y> 0: Positive for pathogen,Y< 0: Negative for pathogen). The reported platform can be quickly adapted for multi‐omics and multiplexed diagnosis of continuously evolving biothreats and global pandemics.

     
    more » « less
  2. Abstract

    Enzymatic DNA amplification‐based approaches involving intercalating DNA‐binding fluorescent dyes and expensive optical detectors are the gold standard for nucleic acid detection. As components of a simplified and miniaturized system, conventional silicon‐based ion sensitive field effect transistors (ISFETs) that measure a decrease in pH due to the generation of pyrophosphates during DNA amplification have been previously reported. In this article, Bst polymerase in a loop‐mediated isothermal amplification (LAMP) reaction combined with target‐specific primers and crumpled graphene field effect transistors (gFETs) to electrically detect amplification by sensing the reduction in primers is used. Graphene is known to adsorb single‐stranded DNA due to noncovalent π–π bonds, but not double‐stranded DNA. This approach does not require any surface functionalization and allows the detection of primer concentrations at the endpoint of reactions. As recently demonstrated, the crumpled gFET over the conventional flat gFET sensors due to their superior sensitivity is chosen. The endpoint of amplification reaction with starting concentrations down to 8 × 10−21min 90 min including the time of amplification and detection is detected. With its high sensitivity and small footprint, this platform will help bring complex lab‐based diagnostic and genotyping amplification assays to the point‐of‐care.

     
    more » « less
  3. Abstract

    Chemiluminescence immunoassay exhibits high sensitivity and signal‐to‐noise ratio, thus attracting great attention in the early diagnosis and dynamic monitoring of diseases. However, the collection of conventional flash‐type chemiluminescence signal (<5 s) relies heavily on automatic sampling and reading instrument. Herein, a novel core‐satellite multifunctional chemiluminescence immunosensor is designed for the efficient enrichment and highly sensitive determination of cancer biomarker carcinoembryonic antigen (CEA) with enhanced and long‐lasting output signal that can be conveniently recorded by a simple microplate plate reading instrument. Anti‐CEA monoclonal antibody 2 (Ab2) modified Fe3O4@SiO2microspheres (Fe3O4@SiO2‐Ab2, 370 nm in diameter) are synthesized as the core for selectively capturing and enriching target CEA in solution, and anti‐human CEA monoclonal antibody 1 (Ab1) and horseradish peroxidase (HRP) co‐immobilized dendritic large‐mesoporous silica nanospheres (MSNs‐HRP/Ab1, 80 nm in diameter, pore size: 17 nm) are synthesized as the satellite for efficient immunological recognition and signal amplification. The as‐designed core‐satellite magnetic chemiluminescence immunosensors exhibit a broad linear range of 0.01−20 ng mL−1and a low detection limit of 3.0 pg mL−1for the convenient, highly specific, and sensitive determination of CEA in human serum. Such core‐satellite chemiluminescence immunosensors are expected to act as a powerful tool for in vitro detection of various biomarkers, overcome the defect of conventional chemiluminescence relying heavily on expensive and bulky automatic instruments and popularize chemiluminescence analysis to primary medical institutions and remote areas.

     
    more » « less
  4. Abstract

    Sensitive detection of pathogens is crucial for early disease diagnosis and quarantine, which is of tremendous need in controlling severe and fatal illness epidemics such as of Ebola virus (EBOV) disease. Serology assays can detect EBOV‐specific antigens and antibodies cost‐effectively without sophisticated equipment; however, they are less sensitive than reverse transcriptase polymerase chain reaction (RT‐PCR) tests. Herein, a 3D plasmonic nanoantenna assay sensor is developed as an on‐chip immunoassay platform for ultrasensitive detection of Ebola virus (EBOV) antigens. The EBOV sensor exhibits substantial fluorescence intensity enhancement in immunoassays compared to flat gold substrate. The nanoantenna‐based biosensor successfully detects EBOV soluble glycoprotein (sGP) in human plasma down to 220 fg mL−1, a significant 240 000‐fold sensitivity improvement compared to the 53 ng mL−1EBOV antigen detection limit of the existing rapid EBOV immunoassay. In a mock clinical trial, the sensor detects sGP‐spiked human plasma samples at two times the limit of detection with 95.8% sensitivity. The results combined highlight the nanosensor's extraordinary capability of detecting EBOV antigen at ultralow concentration compared to existing immunoassay methods. It is a promising next‐generation bioassay platform for early‐stage disease diagnosis and pathogen detection for both public health and national security applications.

     
    more » « less
  5. In this work, based on Fe3O4@AuNPs and double amplified signal Off-On strategy, a simple and sensitive SERS microfluidic chip was constructed to detect microRNA associated with non-small cell lung cancer (NSCLC). Fe3O4@AuNPs have two advantages of SERS enhanced and magnetic adsorption, the introduction of microfluidic chip can realize double amplification of SERS signal. First, the binding of complementary ssDNA and hpDNA moved the Raman signaling molecule away from Fe3O4@AuNPs, at which point the signal was turned off. Second, in the presence of the target microRNA, they were captured by complementary ssDNA and bound to them. HpDNA restored the hairpin conformation, the Raman signaling molecule moved closer to Fe3O4@AuNPs. At this time, the signal was turned on and strong Raman signal was generated. And last, through the magnetic component of SERS microfluidic chip, Fe3O4@AuNPs could be enriched to realize the secondary enhancement of SERS signal. In this way, the proposed SERS microfluidic chip can detect microRNA with high sensitivity and specificity. The corresponding detection of limit (LOD) for miR-21 versus miR-125b was 6.38 aM and 7.94 aM, respectively. This SERS microfluidic chip was promising in the field of early detection of NSCLC.

     
    more » « less