Title: Validation of an enzyme‐linked immunoassay assay for osteocalcin, a marker of bone formation, in dried blood spots
Abstract ObjectivesInvestigating factors that contribute to bone loss and accretion across populations in remote settings is challenging, particularly where diagnostic tools are scarce. To mitigate this challenge, we describe validation of a commercial ELISA assay to measure osteocalcin, a biomarker of bone formation, from dried blood spots (DBS). MethodsWe validated the Osteocalcin Human SimpleStep ELISA kit from Abcam (ab1951214) using 158 matched plasma and DBS samples. Passing‐Bablok regression analysis assessed the relationships between plasma and DBS osteocalcin concentrations. Dilutional linearity and spike and recovery experiments determined if the DBS matrix interfered with osteocalcin measurement, and intra‐ and inter‐assay coefficients of variation (CVs) were calculated. Limit of detection, analyte stability, and specific forms of osteocalcin measured by the kit were also investigated. ResultsMean plasma osteocalcin value was 218.2 ng/mL (range 64.6‐618.1 ng/mL). Linear relationships existed between plasma and DBS concentrations of osteocalcin, with no apparent bias in plasma vs DBS concentrations. There was no apparent interference of the DBS matrix with measurement of osteocalcin in DBS. Intra‐assay CV for DBS was ~8%, while average inter‐assay CV was 14.8%. Limit of detection was 0.34 ng/mL. Osteocalcin concentrations were stable in DBS stored at −28°C and room temperature, but not those stored at 37°C. This ELISA kit detects total osteocalcin. ConclusionsOsteocalcin, a bone formation biomarker, can be measured from DBS. Combined with a previously validated DBS assay for TRACP‐5b, a bone resorption biomarker, these assays have the potential to help researchers disentangle the many factors contributing to bone strength.  more » « less
Award ID(s):
1638786
PAR ID:
10456840
Author(s) / Creator(s):
 ;  ;  ;  ;  ;  ;  
Publisher / Repository:
Wiley Blackwell (John Wiley & Sons)
Date Published:
Journal Name:
American Journal of Human Biology
Volume:
32
Issue:
5
ISSN:
1042-0533
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract ObjectivesA number of basic questions about bone biology have not been answered, including population differences in bone turnover. In part, this stems from the lack of validated minimally invasive biomarker techniques to measure bone formation and resorption in field‐based population‐level research. The present study addresses this gap by validating a fingerprick dried blood spot (fDBS) assay for tartrate‐resistant acid phosphatase 5b (TRACP‐5b), a well‐defined biomarker of bone resorption and osteoclast number. MethodsWe adapted a commercially available enzyme‐linked immunosorbent assay (ELISA) kit from MyBiosource for the quantitative determination of TRACP‐5b levels in serum and plasma for use with DBS. We used a rigorous process of assay modification and validation, including the use of a matched set of 189 adult plasma, fDBS, and venous DBS (vDBS) samples; parameters evaluated included precision, reliability, and analyte stability. ResultsPlasma and DBS TRACP‐5b concentrations showed a linear relationship. There were no systematic differences in TRACP‐5b levels in fDBS and vDBS, indicating no significant differences in TRACP‐5b distribution between capillary and venous blood. Parallelism and spike‐and‐recovery results indicated that matrix factors in DBS do not interfere with measurement of TRACP‐5b levels from DBS using the validated kit. Intra‐ and interassay CVs were 5.0% and 12.1%, respectively. DBS samples should preferably be stored frozen but controlled room temperature storage for up to a month may be acceptable. ConclusionsThis DBS‐based ELISA assay adds to the methodological toolkit available to human biologists and will facilitate research on bone turnover in population studies. 
    more » « less
  2. Abstract The spike protein of SARS-CoV-2 engages the human angiotensin-converting enzyme 2 (ACE2) receptor to enter host cells, and neutralizing antibodies are effective at blocking this interaction to prevent infection. Widespread application of this important marker of protective immunity is limited by logistical and technical challenges associated with live virus methods and venous blood collection. To address this gap, we validated an immunoassay-based method for quantifying neutralization of the spike-ACE2 interaction in a single drop of capillary whole blood, collected on filter paper as a dried blood spot (DBS) sample. Samples are eluted overnight and incubated in the presence of spike antigen and ACE2 in a 96-well solid phase plate. Competitive immunoassay with electrochemiluminescent label is used to quantify neutralizing activity. The following measures of assay performance were evaluated: dilution series of confirmed positive and negative samples, agreement with results from matched DBS-serum samples, analysis of results from DBS samples with known COVID-19 status, and precision (intra-assay percent coefficient of variation; %CV) and reliability (inter-assay; %CV). Dilution series produced the expected pattern of dose–response. Agreement between results from serum and DBS samples was high, with concordance correlation = 0.991. Analysis of three control samples across the measurement range indicated acceptable levels of precision and reliability. Median % surrogate neutralization was 46.9 for PCR confirmed convalescent COVID-19 samples and 0.1 for negative samples. Large-scale testing is important for quantifying neutralizing antibodies that can provide protection against COVID-19 in order to estimate the level of immunity in the general population. DBS provides a minimally-invasive, low cost alternative to venous blood collection, and this scalable immunoassay-based method for quantifying inhibition of the spike-ACE2 interaction can be used as a surrogate for virus-based assays to expand testing across a wide range of settings and populations. 
    more » « less
  3. Enzyme linked immunosorbent assay (ELISA) is one of the most utilized serological methods to diagnose and identify etiologic agents of many infectious diseases and other physiologically important analytes. ELISA can be used either alone or adjunct to other diagnostic methods such as molecular arrays, and other serological techniques. Most ELISA assays utilize reagents that are proteinaceous in nature, which are not very stable and require cold-chain transport systems. Development of a desirable immunoassay requires stability of reagents used and its ability to be stored at room temperature without sacrificing the activity of the reagents or the protein of interest. Metal organic frameworks (MOFs) are a rapidly emerging and evolving class of porous polymeric materials used in a variety of biosensor applications. In this study, we introduce the use of MOFs to stabilize a universal reporter fusion protein, specifically, avidin-like protein (Tam-avidin2) and the small bioluminescent protein Gaussia luciferase (Gluc) forming the fusion reporter, tamavidin2-Gluc (TA2-Gluc). This fusion protein serves as a universal reporter for any assays that utilize biotin–avidin binding strategy. Using SARS-CoV2 S1 spike antigen as the model target antigen, we demonstrated that encapsulation of TA2-Gluc fusion protein using a nano-porous material, zeolitic imidazolate framework-8 (ZIF-8), allows us to store and preserve this reporter protein at room temperature for over 6 months and use it as a reporter for an ELISA assay. Our optimized assay was validated demonstrating a 0.26 μg mL −1 limit of detection, high reproducibility of assay over days, detection of spiked non-virulent SARS-COV2 pseudovirus in real sample matrix, and detection in real COVID-19 infected individuals. This result can lead to the utilization of our TA2-Gluc fusion protein reporter with other assays and potentially in diagnostic technologies in a point-of-care setting. 
    more » « less
  4. Colorimetric enzyme-linked immunosorbent assay (ELISA) has been widely applied as the gold-standard method for cytokine detection for decades. However, it has become a critical challenge to further improve the detection sensitivity of ELISA, as it is limited by the catalytic activity of enzymes. Herein, we report an enhanced colorimetric ELISA for ultrasensitive detection of interleukin-6 (IL-6, as a model cytokine for demonstration) using Pd@Pt core@shell nanodendrites (Pd@Pt NDs) as peroxidase nanomimics (named “Pd@Pt ND ELISA”), pushing the sensitivity up to femtomolar level. Specifically, the Pd@Pt NDs are rationally engineered by depositing Pt atoms on Pd nanocubes (NCs) to generate rough dendrite-like Pt skins on the Pd surfaces via Volmer–Weber growth mode. They can be produced on a large scale with highly uniform size, shape, composition, and structure. They exhibit significantly enhanced peroxidase-like catalytic activity with catalytic constants (Kcat) more than 2000-fold higher than those of horseradish peroxidase (HRP, an enzyme commonly used in ELISA). Using Pd@Pt NDs as the signal labels, the Pd@Pt ND ELISA presents strong colorimetric signals for the quantitative determination of IL-6 with a wide dynamic range of 0.05–100 pg mL−1 and an ultralow detection limit of 0.044 pg mL−1 (1.7 fM). This detection limit is 21-fold lower than that of conventional HRP-based ELISA. The reproducibility and specificity of the Pd@Pt ND ELISA are excellent. More significantly, the Pd@Pt ND ELISA was validated for analyzing IL-6 in human serum samples with high accuracy and reliability through recovery tests. Our results demonstrate that the colorimetric Pd@Pt ND ELISA is a promising biosensing tool for ultrasensitive determination of cytokines and thus is expected to be applied in a variety of clinical diagnoses and fundamental biomedical studies. 
    more » « less
  5. Both long- and short-term glycemic variability have been associated with incident diabetes complications. We evaluated their relative and potential additive effects on incident renal complications in the Action to Control Cardiovascular Risk in Diabetes trial. A marker of short-term glycemic variability, 1,5-anhydroglucitol (1,5-AG), was measured in 4,000 random 12-month postrandomization plasma samples (when hemoglobin A1c [HbA1c] was stable). Visit-to-visit fasting plasma glucose coefficient of variation (CV-FPG) was determined from 4 months postrandomization until the end point of microalbuminuria or macroalbuminuria. Using Cox proportional hazards models, high CV-FPG and low 1,5-AG were independently associated with microalbuminuria after adjusting for clinical risk factors. However, only the CV-FPG association remained after additional adjustment for average HbA1c. Only CV-FPG was a significant risk factor for macroalbuminuria. This post hoc analysis indicates that long-term rather than short-term glycemic variability better predicts the risk of renal disease in type 2 diabetes. Article HighlightsThe relative and potential additive effects of long- and short-term glycemic variability on the development of diabetic complications are unknown. We aimed to assess the individual and combined relationships of long-term visit-to-visit glycemic variability, measured as the coefficient of variation of fasting plasma glucose, and short-term glucose fluctuation, estimated by the biomarker 1,5-anhydroglucitol, with the development of proteinuria. Both estimates of glycemic variability were independently associated with microalbuminuria, but only long-term glycemic variability remained significant after adjusting for average hemoglobin A1c. Our findings suggest that longer-term visit-to-visit glucose variability improves renal disease prediction in type 2 diabetes. 