Title: Programmable Electrochemical Stimulation on a Large-Scale CMOS Microelectrode Array
In this paper we present spatio-temporally controlled electrochemical stimulation of aqueous samples using an integrated CMOS microelectrode array with 131,072 pixels. We demonstrate programmable gold electrodeposition in arbitrary spatial patterns, controllable electrolysis to produce microscale hydrogen bubbles, and spatially targeted electrochemical pH modulation. Dense spatially-addressable electrochemical stimulation is important for a wide range of bioelectronics applications.  more » « less
Award ID(s):
2027108
PAR ID:
10469149
Author(s) / Creator(s):
; ; ;
Publisher / Repository:
IEEE
Date Published:
ISBN:
978-1-6654-6917-3
Page Range / eLocation ID:
439 to 443
Format(s):
Medium: X
Location:
Taipei, Taiwan
Sponsoring Org:
National Science Foundation
More Like this
  1. Electrophysiological stimulation has been widely adopted for clinical diagnostic and therapeutic treatments for modulation of neuronal activity. Safety is a primary concern in an interventional design leveraging the effects of electrical charge injection into tissue in the proximity of target neurons. While modalities of tissue damage during stimulation have been extensively investigated for specific electrode geometries and stimulation paradigms, a comprehensive model that can predict the electrochemical safety limits in vivo doesn’t yet exist. Here we develop a model that accounts for the electrode geometry, inter-electrode separation, material, and stimulation paradigm in predicting safe current injection limits. We performed a parametric investigation of the stimulation limits in both benchtop and in vivo setups for flexible microelectrode arrays with low impedance, high geometric surface area platinum nanorods and PEDOT:PSS, and higher impedance, planar platinum contacts. We benchmark our findings against standard clinical electrocorticography and depth electrodes. Using four, three and two contact electrochemical impedance measurements and comprehensive circuit models derived from these measurements, we developed a more accurate, clinically relevant and predictive model for the electrochemical interface potential. For each electrode configuration, we experimentally determined the geometric correction factors that dictate geometry-enforced current spreading effects. We also determined the electrolysis window from cyclic-voltammetry measurements which allowed us to calculate stimulation current safety limits from voltage transient measurements. From parametric benchtop electrochemical measurements and analyses for different electrode types, we created a predictive equation for the cathodal excitation measured at the electrode interface as a function of the electrode dimensions, geometric factor, material and stimulation paradigm. We validated the accuracy of our equation in vivo and compared the experimentally determined safety limits to clinically used stimulation protocols. Our new model overcomes the design limitations of Shannon’s equation and applies to macro- and micro-electrodes at different density or separation of contacts, captures the breakdown of charge-density based approaches at long stimulation pulse widths, and invokes appropriate power exponents to current, pulse width, and material/electrode-dependent impedance. 
    more » « less
  2. Abstract Electrical stimulation has been critical in the development of an understanding of brain function and disease. Despite its widespread use and obvious clinical potential, the mechanisms governing stimulation in the cortex remain largely unexplored in the context of pulse parameters. Modeling studies have suggested that modulation of stimulation pulse waveform may be able to control the probability of neuronal activation to selectively stimulate either cell bodies or passing fibers depending on the leading polarity. Thus, asymmetric waveforms with equal charge per phase (i.e., increasing the leading phase duration and proportionately decreasing the amplitude) may be able to activate a more spatially localized or distributed population of neurons if the leading phase is cathodic or anodic, respectively. Here, we use two‐photon and mesoscale calcium imaging of GCaMP6s expressed in excitatory pyramidal neurons of male mice to investigate the role of pulse polarity and waveform asymmetry on the spatiotemporal properties of direct neuronal activation with 10‐Hz electrical stimulation. We demonstrate that increasing cathodic asymmetry effectively reduces neuronal activation and results in a more spatially localized subpopulation of activated neurons without sacrificing the density of activated neurons around the electrode. Conversely, increasing anodic asymmetry increases the spatial spread of activation and highly resembles spatiotemporal calcium activity induced by conventional symmetric cathodic stimulation. These results suggest that stimulation polarity and asymmetry can be used to modulate the spatiotemporal dynamics of neuronal activity thus increasing the effective parameter space of electrical stimulation to restore sensation and study circuit dynamics. 
    more » « less
  3. This paper presents a technique for achieving spatially targeted neural stimulation with suppression of driver nonideality-induced common-mode (CM) artifact in low-latency closed-loop neuromodulation applications. The proposed approach utilizes computationally guided concurrent stimulation across multiple electrodes to achieve spatial selectivity in stimulation. The proposed architecture supports flexible storage of multiple, precomputed vector stimulation patterns in integrated memory. A selected stimulation pattern can be quickly accessed and administered in response to decoded neural activity. Additionally, a combination of the stimulator circuit architecture and mixed-signal current imbalance compensation techniques effectively suppress CM artifacts to below 50 mV. These techniques are demonstrated in a 180 nm HV CMOS test-chip containing 46 stimulation drivers of 26 V compliance and validated through a combination of bench, saline, and in vivo tests. 
    more » « less
  4. Abstract Electroresponsive hydrogels possess a conducting material component and respond to electric stimulation through reversible absorption and expulsion of water. The high level of hydration, soft elastomeric compliance, biocompatibility, and enhanced electrochemical properties render these hydrogels suitable for implantation in the brain to enhance the transmission of neural electric signals and ion transport. This review provides an overview of critical electroresponsive hydrogel properties for augmenting electric stimulation in the brain. A background on electric stimulation in the brain through electroresponsive hydrogels is provided. Common conducting materials and general techniques to integrate them into hydrogels are briefly discussed. This review focuses on and summarizes advances in electric stimulation of electroconductive hydrogels for therapeutic applications in the brain, such as for controlling delivery of drugs, directing neural stem cell differentiation and neurogenesis, improving neural biosensor capabilities, and enhancing neural electrode‐tissue interfaces. The key challenges in each of these applications are discussed and recommendations for future research are also provided. 
    more » « less
  5. The diffusion layer created by transition metal (TM) dissolution is ubiquitous at the electrochemical solid-liquid interface and plays a key role in determining electrochemical performance. Tracking the spatiotemporal dynamics of the diffusion layer has remained an unresolved challenge. With spatially resolved synchrotron X-ray fluorescence microscopy and micro-X-ray absorption spectroscopy, we demonstrate the in situ visualization and chemical identification of the dynamic diffusion layer near the electrode surface under electrochemical operating conditions. Our method allows for direct mapping of the reactive electrochemical interface and provides insights into engineering the diffusion layer for improving electrochemical performance. 
    more » « less