Title: Multi-frequency MEMS acoustic emission sensor
In this paper, a multi-frequency MEMS acoustic emission (AE) sensor is designed, characterized, and tested. The sensor includes sixteen individual resonators tuned in the range of 100 kHz to 700 kHz. The resonator frequencies are selected to form constructive interference when they are connected in parallel to increase the signal-to-noise ratio. Each resonator is comprised of a membrane that forms the mass and four beams that provide stiffness. The membrane size is kept the same for each resonator to have approximately the same sensitivity per frequency. The influence of spring elements on the resonant frequency and the sensitivity is numerically demonstrated. The sensor is manufactured using MEMSCAP PiezoMUMPs. The characterization experiments show a slight shift in the resonant frequency of individual resonators compared to the design values. The MEMS sensor is packaged using a custom-designed printed circuit board to improve the signal-to-noise ratio. The sensor performance is compared with a conventional AE sensor. The sensitivity and frequency bandwidth of the MEMS AE device is brought to a comparable level to bulky AE sensors.  more » « less
Award ID(s):
2016444
PAR ID:
10469290
Author(s) / Creator(s):
; ; ;
Publisher / Repository:
Sensors and Actuators A: Physical
Date Published:
Journal Name:
Sensors and Actuators A: Physical
Volume:
362
Issue:
C
ISSN:
0924-4247
Page Range / eLocation ID:
114648
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. null (Ed.)
    This paper presents a review of state-of-the-art micro-electro-mechanical-systems (MEMS) acoustic emission (AE) sensors. MEMS AE sensors are designed to detect active defects in materials with the transduction mechanisms of piezoresistivity, capacitance or piezoelectricity. The majority of MEMS AE sensors are designed as resonators to improve the signal-to-noise ratio. The fundamental design variables of MEMS AE sensors include resonant frequency, bandwidth/quality factor and sensitivity. Micromachining methods have the flexibility to tune the sensor frequency to a particular range, which is important, as the frequency of AE signal depends on defect modes, constitutive properties and structural composition. This paper summarizes the properties of MEMS AE sensors, their design specifications and applications for detecting the simulated and real AE sources and discusses the future outlook. 
    more » « less
  2. MEMS resonators integrated with CMOS feedback networks have a potentially wide field of applications as oscillator circuits in communications and sensor systems. However, considerable advancements to this nascent technology are required to realize such a vision. We present a configurable CMOS chip which facilitates the development of MEMS-referenced oscillators, especially for timing and sensing applications in harsh environments. The chip has been designed in the OnSemi 3M2P 0.5 um process. It supports MEMS resonators with various frequencies (10–120 kHz), resonant modes, and impedance levels, thus allowing interfacing to a wide range of devices. This paper describes analysis, design, and simulation results. 
    more » « less
  3. Abstract Implementing microelectromechanical system (MEMS) resonators calls for detailed microscopic understanding of the devices, such as energy dissipation channels, spurious modes, and imperfections from microfabrication. Here, we report the nanoscale imaging of a freestanding super-high-frequency (3 – 30 GHz) lateral overtone bulk acoustic resonator with unprecedented spatial resolution and displacement sensitivity. Using transmission-mode microwave impedance microscopy, we have visualized mode profiles of individual overtones and analyzed higher-order transverse spurious modes and anchor loss. The integrated TMIM signals are in good agreement with the stored mechanical energy in the resonator. Quantitative analysis with finite-element modeling shows that the noise floor is equivalent to an in-plane displacement of 10 fm/√Hz at room temperatures, which can be further improved under cryogenic environments. Our work contributes to the design and characterization of MEMS resonators with better performance for telecommunication, sensing, and quantum information science applications. 
    more » « less
  4. In this work, we present a battery-less wireless Micro-Electro-Mechanical (MEMS)-based respiration sensor capable of measuring the respiration profile of a human subject from up to 2 m distance from the transceiver unit for a mean excitation power of 80 µW and a measured SNR of 124.8 dB at 0.5 m measurement distance. The sensor with a footprint of ~10 cm2 is designed to be inexpensive, maximize user mobility, and cater to applications where disposability is desirable to minimize the sanitation burden. The sensing system is composed of a custom UHF RFID antenna, a low-loss piezoelectric MEMS resonator with two modes within the frequency range of interest, and a base transceiver unit. The difference in temperature and moisture content of inhaled and exhaled air modulates the resonance frequency of the MEMS resonator which in turn is used to monitor respiration. To detect changes in the resonance frequency of the MEMS devices, the sensor is excited by a pulsed sinusoidal signal received through an external antenna directly coupled to the device. The signal reflected from the device through the antenna is then analyzed via Fast Fourier Transform (FFT) to extract and monitor the resonance frequency of the resonator. By tracking the resonance frequency over time, the respiration profile of a patient is tracked. A compensation method for the removal of motion-induced artifacts and drift is proposed and implemented using the difference in the resonance frequency of two resonance modes of the same resonator. 
    more » « less
  5. In this paper the performances of two spectrophones for quartz-enhanced photoacoustic spectroscopy (QEPAS)-based ethane gas sensing were tested and compared. Each spectrophone contains a quartz tuning fork (QTF) acoustically coupled with a pair of micro-resonator tubes and having a fundamental mode resonance frequency of 32.7 kHz (standard QTF) and 12.4 kHz (custom QTF), respectively. The spectrophones were implemented into a QEPAS acoustic detection module (ADM) together with a preamplifier having a gain bandwidth optimized for the respective QTF resonance frequency. Each ADM was tested for ethane QEPAS sensing, employing a custom pigtailed laser diode emitting at ~1684 nm as the exciting light source. By flowing 1% ethane at atmospheric pressure, a signal-to-noise ratio of 453.2 was measured by implementing the 12.4 kHz QTF-based ADM, ~3.3 times greater than the value obtained using a standard QTF. The minimum ethane concentration detectable using a 100 ms lock-in integration time achieving the 12.4 kHz custom QTF was 22 ppm. 
    more » « less