skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Title: LEAP-UCD-2017 Experiments (Liquefaction Experiments and Analysis Projects)
Twenty-four centrifuge model tests of liquefaction and lateral spreading, performed as part of a round robin test program, are shared and compared in this archive. Please see the general report section of the published project for an overview comparison and background of all of the experiments. One document in the report (with “ReadMe” in the file name) describes the organization of the data archive. The comparisons presented in the general report section will serve as an index to help the users find individual experiments of interest. This data from 24 model tests is published as nine separate experiments in this archive (one experiment per centrifuge facility). Each experiment includes two or three model tests and each model test includes between one and three destructive shaking events. All of the tests modeled a 4 m thick deposit of Ottawa F-65 sand with a 5-degree surface slope in a rigid box. The tests covered a range of ground motion intensities and a range of relative densities to define the median response and the sensitivity of the response to relative density and shaking intensity. The nine centrifuge facilities involved in this test program included Cambridge University (UK), Ehime University (Japan), IFSTTAR (France), NCU (Taiwan), KAIST (Korea), Kyoto University (Japan), RPI (USA), UC Davis (USA), and Zhejiang University (China).  more » « less
Award ID(s):
1635524
PAR ID:
10474521
Author(s) / Creator(s):
; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; more » ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; « less
Publisher / Repository:
Designsafe-CI
Date Published:
Subject(s) / Keyword(s):
Liquefaction Model Tests Round Robin Tests Centrifuge Experiments Simulations Validation
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Twenty-four centrifuge model tests have been conducted at nine different geotechnical centrifuge facilities around the world as part of the international LEAP effort (liquefaction experiments and analysis projects). All of the centrifuge models represent a 4 m deep 5 degree sloping submerged sand deposit. The mean effective PGA of the input motion for all of the experiments was approximately 0.15 g and the mean relative density was approximately 65%, but the effective PGA’s varied between about 0.07 g and 0.3 g, and the relative densities varied between about 40% and 75%. The test matrix was designed to enable experimental quantification of not only the median response but also the trend and sensitivity of the model response to density and shaking intensity. Quantification of the sensitivity of the response to initial conditions is a prerequisite for objective evaluation of the quality of the model test data. In other words, a discrepancy between two experiments should be evaluated after accounting for the uncertainty in the initial conditions and the sensitivity of the response to initial conditions. For the first time, a sufficient number of experiments has been performed on a similar problem to provide meaningful quantitative evaluation of the trend between PGA, density, and displacement. The sensitivity is quantified by the gradient of the trend and the uncertainty of the trend is quantified from the residuals between the fitting data and the trend. 
    more » « less
  2. Inverse analyses were used to evaluate the degree of partial drainage occurring during dynamic shaking of liquefying soil profiles in a set of centrifuge model tests. Three tests were performed using the 9-m radius centrifuge at the UC Davis Center for Geotechnical Modeling on saturated Ottawa sand models with initial relative densities of 25, 43, and 80%. Models were subjected to multiple sinusoidal shaking events with acceleration amplitudes ranging from 0.03 to 0.55g. Densely spaced pore pressure transducer arrays provided profiles of pore pressure generation and dissipation; inverse analyses of the pore pressure data were used to obtain volumetric strain profiles during shaking and dissipation. Surface settlements computed by integrating the volumetric strain profiles are compared to surface settlements measured from linear potentiometers. The magnitude of the volumetric strains due to partial drainage and their potential effects on liquefaction responses are discussed. 
    more » « less
  3. We present data and metadata from a centrifuge testing program that was designed to investigate the seismic responses of buried circular and rectangular culverts. The specimen configurations were based on Caltrans Standard Plans, and the scope of research was to compare the experimental findings with the design method described in the NCHRP Report 611 as well as to formulate preliminary recommendations for Caltrans practice. A relatively flexible pipe and a stiff box-shaped specimen embedded in dense sand were tested in the centrifuge at the Center for Geotechnical Modeling at University of California, Davis and were subjected to a set of broadband and harmonic input motions. Responses were recorded in the soil and in the embedded structures using a dense array of instruments. Measured quantities included specimen accelerations, bending strains, and hoop strains; soil accelerations, shear-wave velocities, settlements, and lateral displacements; and accelerations of the centrifuge's shaking table. This data paper describes the tests and summarizes the generated data, which are archived at DesignSafe.ci.org (DOI: 10.17603/DS2XW9R) and are accessible through an interactive Jupyter notebook. 
    more » « less
  4. This paper presents the development, implementation and experimental evaluation of a new crack detection mechanism for centrifuge modelling. The proposed mechanism is a brittle conductor bonded to cement providing a binary indication of if, and when, a sensor is cracked. The results of a pair of large centrifuge tests were used to evaluate the effectiveness of the proposed crack detection mechanism. Each test model included a soil profile consisting of a 23 m thick layer of lightly over-consolidated clay, underlain and overlain by thin layers of dense sand. The centrifuge models had two separate zones, a zone without reinforcement and a zone with an ‘embedded’ soil–cement grid, which had a unit cell area replacement ratio A r  = 24%. Models were subjected to 13 different shaking events with peak base accelerations ranging from 0·01 to 0·55g. The performance of the proposed crack detection mechanism was examined using (i) post-test crack mapping in the soil–cement grids, (ii) results of the crack detection system and (iii) time series of accelerations, displacements and footing rotation. The results from the centrifuge test showed that the proposed crack detection method accurately captured if, and when, cracking occurred in the soil–cement grid at the locations of the sensors. 
    more » « less
  5. This paper investigates and presents the numerical modeling and validation of the response of a uniform clean sand using monotonic and cyclic laboratory tests as well as a centrifuge model test comprised of a submerged slope. The dynamic response of the sand is modeled using a critical state compatible, stress ratio-based, bounding surface plasticity constitutive model (PM4Sand), implemented in the commercial finite-difference platform FLAC, and PM4Sand’s performance is evaluated against a comprehensive testing program comprised of laboratory data and a well-instrumented centrifuge model test. Three different calibrations informed by the lab and centrifuge data are performed and the goodness of the predictions is discussed. Conclusions are drawn with regards to the performance of the simulations against the laboratory and centrifuge data, and recommendations about the calibration of the model are provided. 
    more » « less