Title: The motor and the brake of the trailing leg in human walking: transtibial amputation limits ankle–knee torque covariation
Lower-limb amputation limits inherent motor abundance in the locomotor system and impairs walking mechanics. Able- bodied walkers vary ankle torque to adjust step-to-step leg force production as measured by resultant ground reaction forces. Simultaneously, knee torque covaries with ankle torque to act as a brake, resulting in consistent peak leg power output meas- ured by external mechanical power generated on the center of mass. Our objective was to test how leg force control during gait is affected by joint torque variance structure in the amputated limb. Within the framework of the uncontrolled manifold analysis, we measured the Index of Motor Abundance (IMA) to quantify joint torque variance structure of amputated legs and its effect on leg force, where IMA>0 indicates a stabilizing structure. We further evaluated the extent to which IMA in amputated legs used individual (INV) and coordinated (COV) joint control strategies. Amputated legs produced IMA and INV values similar to intact legs, indicating that torque deviations of the prosthetic ankle can modulate leg force at the end of stance phase. However, we observed much lower COV values in the amputated leg relative to intact legs indicating that biological knee joint torque of the amputated leg does not covary with prosthetic ankle torque. This observation sug- gests inter-joint coordination during gait is significantly limited as a result of transtibial amputation and may help explain the higher rate of falls and impaired balance recovery in this population, pointing to a greater need to focus on inter-joint coordination within the amputated limb.  more » « less
Award ID(s):
1734416
PAR ID:
10481851
Author(s) / Creator(s):
;
Publisher / Repository:
Springer
Date Published:
Journal Name:
Experimental Brain Research
Volume:
241
Issue:
1
ISSN:
0014-4819
Page Range / eLocation ID:
161 to 174
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract Background After above-knee amputation, the missing biological knee and ankle are replaced with passive prosthetic devices. Passive prostheses are able to dissipate limited amounts of energy using resistive damper systems during “negative energy” tasks like sit-down. However, passive prosthetic knees are not able to provide high levels of resistance at the end of the sit-down movement when the knee is flexed, and users need the most support. Consequently, users are forced to over-compensate with their upper body, residual hip, and intact leg, and/or sit down with a ballistic and uncontrolled movement. Powered prostheses have the potential to solve this problem. Powered prosthetic joints are controlled by motors, which can produce higher levels of resistance at a larger range of joint positions than passive damper systems. Therefore, powered prostheses have the potential to make sitting down more controlled and less difficult for above-knee amputees, improving their functional mobility. Methods Ten individuals with above-knee amputations sat down using their prescribed passive prosthesis and a research powered knee-ankle prosthesis. Subjects performed three sit-downs with each prosthesis while we recorded joint angles, forces, and muscle activity from the intact quadricep muscle. Our main outcome measures were weight-bearing symmetry and muscle effort of the intact quadricep muscle. We performed paired t-tests on these outcome measures to test for significant differences between passive and powered prostheses. Results We found that the average weight-bearing symmetry improved by 42.1% when subjects sat down with the powered prosthesis compared to their passive prostheses. This difference was significant (p = 0.0012), and every subject’s weight-bearing symmetry improved when using the powered prosthesis. Although the intact quadricep muscle contraction differed in shape, neither the integral nor the peak of the signal was significantly different between conditions (integral p > 0.01, peak p > 0.01). Conclusions In this study, we found that a powered knee-ankle prosthesis significantly improved weight-bearing symmetry during sit-down compared to passive prostheses. However, we did not observe a corresponding decrease in intact-limb muscle effort. These results indicate that powered prosthetic devices have the potential to improve balance during sit-down for individuals with above-knee amputation and provide insight for future development of powered prosthetics. 
    more » « less
  2. In this article, we present the design of a powered knee–ankle prosthetic leg, which implements high-torque actuators with low-reduction transmissions. The transmission coupled with a high-torque and low-speed motor creates an actuator with low mechanical impedance and high backdrivability. This style of actuation presents several possible benefits over modern actuation styles in emerging robotic prosthetic legs, which include free-swinging knee motion, compliance with the ground, negligible unmodeled actuator dynamics, less acoustic noise, and power regeneration. Benchtop tests establish that both joints can be backdriven by small torques ( ∼ 1–3 N ⋅ m) and confirm the small reflected inertia. Impedance control tests prove that the intrinsic impedance and unmodeled dynamics of the actuator are sufficiently small to control joint impedance without torque feedback or lengthy tuning trials. Walking experiments validate performance under the designed loading conditions with minimal tuning. Finally, the regenerative abilities, low friction, and small reflected inertia of the presented actuators reduced power consumption and acoustic noise compared to state-of-the-art powered legs. 
    more » « less
  3. Current lower-limb prostheses do not provide active assistance in postural control tasks to maintain the user’s balance, particularly in situations of perturbation. In this study, we aimed to address this missing function by enabling neural control of robotic lower-limb prostheses. Specifically, electromyographic (EMG) signals (amplified neural control signals) recorded from antagonistic residual ankle muscles were used to drive a robotic prosthetic ankle directly and continuously. Participants with transtibial amputation were recruited and trained in using the EMG-driven robotic ankle. We studied how using the EMG-controlled ankle affected the participants’ anticipatory and compensatory postural control strategies and stability under expected perturbations compared with using their daily passive devices. We investigated the similarity of neuromuscular coordination (by analyzing motor modules) of the participants, using either device in a postural sway task, to that of able-bodied controls. Results showed that, compared with their passive prosthesis, the EMG-controlled prosthesis enabled participants to use near-normative postural control strategies, as evidenced by improved between-limb symmetry in intact-prosthetic center-of-pressure and joint angle excursions. Participants substantially improved postural stability, as evidenced by a reduction in steps or falls using the EMG-controlled prosthetic ankle. Furthermore, after relearning to use residual ankle muscles to drive the robotic ankle in postural control, nearly all participants’ motor module structure shifted toward that observed in individuals without limb amputations. Here, we have demonstrated the potential benefit of direct EMG control of robotic lower limb prostheses to restore normative postural control strategies (both neural and biomechanical) toward enhancing standing postural stability in amputee users. 
    more » « less
  4. Powered exoskeletons for gait rehabilitation and mobility assistance are currently available for the adult population and hold great promise for children with mobility limiting conditions. Described here is the development and key features of a modular, lightweight and customizable powered exoskeleton for assist-as-needed overground walking and gait rehabilitation. The pediatric lower-extremity gait system (PLEGS) exoskeleton contains bilaterally active hip, knee and ankle joints and assist-as-needed shared control for young children with lower-limb disabilities such as those present in the Cerebral Palsy, Spina Bifida and Spinal Cord Injured populations. The system is comprised of six joint control modules, one at each hip, knee and ankle joint. The joint control module, features an actuator and motor driver, microcontroller, torque sensor to enable assist-as-needed control, inertial measurement unit and system monitoring sensors. Bench-testing results for the proposed joint control module are also presented and discussed. 
    more » « less
  5. Jiang, Jingang (Ed.)
    Most current powered transfemoral prostheses are designed based on replicating normal anatomy with the inclusion of a revolute knee joint. Prosthesis users often have issues achieving proper leg length to maintain balance and perform push-off during stance, and to ensure sufficient toe clearance during swing. There is a clinical opportunity to develop a powered prosthesis that linearly shortens and lengthens during ambulation with a prismatic joint for improved leg length properties. To build on previous work, the research in this manuscript focuses on designing the physical device, the leg length actuation profile, and the control scheme. Based on gait analyses of two prosthesis users, the device provides an appropriate leg length actuation profile with sufficient shortening for toe clearance (exhibited by the greater prosthetic vs. intact side toe clearance) and lengthening for forward propulsion (exhibited by the ground reaction force peak in late stance). The device also has a motor torque and velocity capable of supporting up to a 90 kg user during normal ambulation, a control scheme with an adjustable actuation cycle based on gait cadence (matching within 2 ms), and a more compact mechanical system design (4.5 kg) less than anatomical weight requirements (5.5 kg). Additionally, the prosthesis users tested were highly encouraging of their stability, mobility, and safety while ambulating with the device. 
    more » « less