skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Title: Harnessing Machine Learning and Physiological Knowledge for a Novel EMG-Based Neural-Machine Interface
Objective: In this study, we aimed to develop a novel electromyography (EMG)-based neural machine interface (NMI), called the Neural Network-Musculoskeletal hybrid Model (N2M2), to decode continuous joint angles. Our approach combines the concepts of machine learning and musculoskeletal modeling. Methods: We compared our novel design with a musculoskeletal model (MM) and 2 continuous EMG decoders based on artificial neural networks (ANNs): multilayer perceptrons (MLPs) and nonlinear autoregressive neural networks with exogenous inputs (NARX networks). EMG and joint kinematics data were collected from 10 non-disabled and 1 transradial amputee subject. The offline performance tested across 3 different conditions (i.e., varied arm postures, shifted electrode locations, and noise-contaminated EMG signals) and online performance for a virtual postural matching task was quantified. Finally, we implemented the N2M2 to operate a prosthetic hand and tested functional task performance. Results: The N2M2 made more accurate predictions than the MLP in all postures and electrode locations (p < 0.003). For estimated MCP joint angles, the N2M2 was less sensitive to noisy EMG signals than the MM or NARX network with respect to error (p < 0.032) as well as the NARX network with respect to correlation (p = 0.007). Additionally, the N2M2 had better online task performance than the NARX network (p ≤ 0.030). Conclusion: Overall, we have found that combining the concepts of machine learning and musculoskeletal modeling has resulted in a more robust joint kinematics decoder than either concept individually. Significance: The outcome of this study may result in a novel, highly reliable controller for powered prosthetic hands.  more » « less
Award ID(s):
1856441
PAR ID:
10482735
Author(s) / Creator(s):
; ; ;
Publisher / Repository:
IEEE
Date Published:
Journal Name:
IEEE Transactions on Biomedical Engineering
Volume:
70
Issue:
4
ISSN:
0018-9294
Page Range / eLocation ID:
1125 to 1136
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. null (Ed.)
    A loss of individuated finger movement affects critical aspects of daily activities. There is a need to develop neural-machine interface techniques that can continuously decode single finger movements. In this preliminary study, we evaluated a novel decoding method that used finger-specific motoneuron firing frequency to estimate joint kinematics and fingertip forces. High-density electromyogram (EMG) signals were obtained during which index or middle fingers produced either dynamic flexion movements or isometric flexion forces. A source separation method was used to extract motor unit (MU) firing activities from a single trial. A separate validation trial was used to only retain the MUs associated with a particular finger. The finger-specific MU firing activities were then used to estimate individual finger joint angles and isometric forces in a third trial using a regression method. Our results showed that the MU firing based approach led to smaller prediction errors for both joint angles and forces compared with the conventional EMG amplitude based method. The outcomes can help develop intuitive neural-machine interface techniques that allow continuous single-finger level control of robotic hands. In addition, the previously obtained MU separation information was applied directly to new data, and it is therefore possible to enable online extraction of MU firing activities for real-time neural-machine interactions. 
    more » « less
  2. Current lower-limb prostheses do not provide active assistance in postural control tasks to maintain the user’s balance, particularly in situations of perturbation. In this study, we aimed to address this missing function by enabling neural control of robotic lower-limb prostheses. Specifically, electromyographic (EMG) signals (amplified neural control signals) recorded from antagonistic residual ankle muscles were used to drive a robotic prosthetic ankle directly and continuously. Participants with transtibial amputation were recruited and trained in using the EMG-driven robotic ankle. We studied how using the EMG-controlled ankle affected the participants’ anticipatory and compensatory postural control strategies and stability under expected perturbations compared with using their daily passive devices. We investigated the similarity of neuromuscular coordination (by analyzing motor modules) of the participants, using either device in a postural sway task, to that of able-bodied controls. Results showed that, compared with their passive prosthesis, the EMG-controlled prosthesis enabled participants to use near-normative postural control strategies, as evidenced by improved between-limb symmetry in intact-prosthetic center-of-pressure and joint angle excursions. Participants substantially improved postural stability, as evidenced by a reduction in steps or falls using the EMG-controlled prosthetic ankle. Furthermore, after relearning to use residual ankle muscles to drive the robotic ankle in postural control, nearly all participants’ motor module structure shifted toward that observed in individuals without limb amputations. Here, we have demonstrated the potential benefit of direct EMG control of robotic lower limb prostheses to restore normative postural control strategies (both neural and biomechanical) toward enhancing standing postural stability in amputee users. 
    more » « less
  3. Objective: Robust neural decoding of intended motor output is crucial to enable intuitive control of assistive devices, such as robotic hands, to perform daily tasks. Few existing neural decoders can predict kinetic and kinematic variables simultaneously. The current study developed a continuous neural decoding approach that can concurrently predict fingertip forces and joint angles of multiple fingers. Methods: We obtained motoneuron firing activities by decomposing high-density electromyogram (HD EMG) signals of the extrinsic finger muscles. The identified motoneurons were first grouped and then refined specific to each finger (index or middle) and task (finger force and dynamic movement) combination. The refined motoneuron groups (separate matrix) were then applied directly to new EMG data in real-time involving both finger force and dynamic movement tasks produced by both fingers. EMG-amplitude-based prediction was also performed as a comparison. Results: We found that the newly developed decoding approach outperformed the EMG-amplitude method for both finger force and joint angle estimations with a lower prediction error (Force: 3.47±0.43 vs 6.64±0.69% MVC, Joint Angle: 5.40±0.50° vs 12.8±0.65°) and a higher correlation (Force: 0.75±0.02 vs 0.66±0.05, Joint Angle: 0.94±0.01 vs 0.5±0.05) between the estimated and recorded motor output. The performance was also consistent for both fingers. Conclusion: The developed neural decoding algorithm allowed us to accurately and concurrently predict finger forces and joint angles of multiple fingers in real-time. Significance: Our approach can enable intuitive interactions with assistive robotic hands, and allow the performance of dexterous hand skills involving both force control tasks and dynamic movement control tasks. 
    more » « less
  4. A reliable and functional neural interface is necessary to control individual finger movements of assistive robotic hands. Non-invasive surface electromyogram (sEMG) can be used to predict fingertip forces and joint kinematics continuously. However, concurrent prediction of kinematic and dynamic variables in a continuous manner remains a challenge. The purpose of this study was to develop a neural decoding algorithm capable of concurrent prediction of fingertip forces and finger dynamic movements. High-density electromyogram (HD-EMG) signal was collected during finger flexion tasks using either the index or middle finger: isometric, dynamic, and combined tasks. Based on the data obtained from the two first tasks, motor unit (MU) firing activities associated with individual fingers and tasks were derived using a blind source separation method. MUs assigned to the same tasks and fingers were pooled together to form MU pools. Twenty MUs were then refined using EMG data of a combined trial. The refined MUs were applied to a testing dataset of the combined task, and were divided into five groups based on the similarity of firing patterns, and the populational discharge frequency was determined for each group. Using the summated firing frequencies obtained from five groups of MUs in a multivariate linear regression model, fingertip forces and joint angles were derived concurrently. The decoding performance was compared to the conventional EMG amplitude-based approach. In both joint angles and fingertip forces, MU-based approach outperformed the EMG amplitude approach with a smaller prediction error (Force: 5.36±0.47 vs 6.89±0.39 %MVC, Joint Angle: 5.0±0.27° vs 12.76±0.40°) and a higher correlation (Force: 0.87±0.05 vs 0.73±0.1, Joint Angle: 0.92±0.05 vs 0.45±0.05) between the predicted and recorded motor output. The outcomes provide a functional and accurate neural interface for continuous control of assistive robotic hands. 
    more » « less
  5. Robotic exoskeletons have the capability to improve community ambulation in aging individuals. These exoskeleton controllers utilize different environmental information such as walking speeds and slope inclines to provide corresponding assistance. Several numerical approaches for estimating this environmental information have been implemented; however, they tend to be limited during dynamic changes. A possible solution is a machine learning model utilizing the user's electromyography (EMG) signals along with mechanical sensor data. We developed a neural network-based walking speed and slope estimator for a powered hip exoskeleton and explored the EMG signal contributions in both static and dynamic settings while wearing the device. We also analyzed the performance of different EMG electrode placements. The resulting machine learning model achieved error rates below 0.08 m/s RMSE and 1.3 RMSE. Our study findings from four able-bodied and two elderly subjects indicate that EMG can improve the performance by reducing the error rate by 14.8% compared to the model using only mechanical sensors. Additionally, results show that using EMG electrode configuration within the exoskeleton interface region is sufficient for the EMG model performance. 
    more » « less