We provide evidence that Terrestrial Gamma‐Ray Flashes (TGFs), in well isolated thunderstorms, tend to occur during periods of low and declining flash rates, and when the flash amplitudes are larger than average. This conclusion comes from examining the results of 371 manually tracked TGF‐producing thunderstorms. Fermi‐GBM identified TGFs are used for this analysis and lightning data come from both World Wide Lightning Location Network and Earth Networks Total Lightning Network. The data from these storms suggest that TGFs are likely to occur in almost every phase of storms that last longer than an hour, but tend to occur later on in shorter storms. We also note that, in short storms, TGFs are more likely to accompany a flash when the flash rates of the storm are lower than average, and they are less likely per flash during the peak flash rate periods of the storms. We find that the tendency for TGFs to occur while the flash rate is falling and when the amplitudes of flashes (the sum of the absolute values of peak currents of all constituent sferics in the flash) are larger than average, does not depend strongly on the duration of the storms. This implies that not just any lightning flash can or even will produce a TGF, but that the electrical conditions of the storm play a crucial role in TGF production.
The Amazon Basin, which plays a critical role in the carbon and water cycle, is under stress due to changes in climate, agricultural practices, and deforestation. The effects of thermodynamic and microphysical forcing on the strength of thunderstorms in the Basin (75–45°W, 0–15°S) were examined during the pre‐monsoon season (mid‐August through mid‐December), a period with large variations in aerosols, intense convective storms, and plentiful flashes. The analysis used measurements of radar reflectivity, ice water content (IWC), and aerosol type from instruments aboard the CloudSat and CALIPSO satellites, flash rates from the ground‐based Sferics Timing and Ranging Network, and total aerosol optical depth (AOD) from a surface network and a meteorological re‐analysis. After controlling for convective available potential energy (CAPE), it was found that thunderstorms that developed under dirty (high‐AOD) conditions were 1.5 km deeper, had 50% more IWC, and more than two times as many flashes as storms that developed under clean conditions. The sensitivity of flashes to AOD was largest for low values of CAPE where increases of more than a factor of three were observed. The additional ice water indicated that these deeper systems had higher vertical velocities and more condensation nuclei capable of sustaining higher concentrations of water and large hydrometeors in the upper troposphere. Flash rates were also found to be larger during periods when smoke rather than dust was common in the lower troposphere, likely because smoky periods were less stable due to higher values of CAPE and AOD and lower values of mid‐tropospheric relative humidity.
more » « less- NSF-PAR ID:
- 10489873
- Publisher / Repository:
- DOI PREFIX: 10.1029
- Date Published:
- Journal Name:
- Journal of Geophysical Research: Atmospheres
- Volume:
- 129
- Issue:
- 3
- ISSN:
- 2169-897X
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
Abstract -
A multi-variable investigation of thunderstorm environments in two distinct geographic regions is conducted to assess the aerosol and thermodynamic environments surrounding thunderstorm initiation. 12-years of cloud-to-ground (CG) lightning flash data are used to reconstruct thunderstorms occurring in a 225 km radius centered on the Washington, DC. and Kansas City Metropolitan Regions. A total of 196,836 and 310,209 thunderstorms were identified for Washington, D.C. and Kansas City, MO, respectively. Hourly meteorological and aerosol data were then merged with the thunderstorm event database. Evidence suggests, warm season thunderstorm environments in benign synoptic conditions are considerably different in thermodynamics, aerosol properties, and aerosol concentrations within the Washington, D.C. and Kansas City regions. However, thunderstorm intensity, as measured by flash counts, appears regulated by similar thermodynamic-aerosol relationships despite the differences in their ambient environments. When examining thunderstorm initiation environments, there exists statistically significant, positive relationships between convective available potential energy (CAPE) and flash counts. Aerosol concentration also appears to be a more important quantity than particle size for lightning augmentation.more » « less
-
Abstract We gridded 11 years of cloud‐to‐ground (CG) flashes detected by the U.S. National Lightning Detection Network during the warm season in 15 km × 15 km × 15 min grid cells to identify storms with substantial CG flash rates clearly dominated by flashes lowering one polarity of charge to the ground or the other (+CG flashes vs. −CG flashes). Previous studies in the central United States had found that the gross charge distribution of storms dominated by +CG flashes included a large upper negative charge over a large middle level positive charge, a reversal of the usual polarities. In each of seven regions spanning the contiguous United States (CONUS), we compared 17 environmental parameters of storms dominated by +CG flashes with those of storms dominated by –CG flashes. These parameters were chosen based on their expected roles in modulating supercooled liquid water content (SLWC) in the updraft because laboratory experiments have shown that SLWC affects the polarity of charge exchanged during rebounding collisions between riming graupel and small ice particles in the mixed phase region. This, in turn, would affect the vertical polarity of a storm's charge distribution and the dominant polarity of CG flashes. Our results suggest that the combination of parameters conducive to dominant +CG flash activity and, by inference, to anomalous storm charge structure varies widely from region to region, the lack of a favorable value of any particular parameter in a given region being offset by favorable values of one or more other parameters.
-
Abstract In Part I, an electrification scheme was described and a simulation of an observed cold-based storm from the U.S. Great Plains was validated with electrical observations. Most charge in the storm was separated by rebounding collisions of secondary ice originating from prior graupel–snow collisions. In this Part II, sensitivity tests are performed with the control simulation (Part I) and influences from environmental factors (aerosols, temperature, moisture, and shear) on lightning are elucidated. Environmental factors [e.g., convective available potential energy (CAPE)] controlling updraft speed are salient. When ascent is reduced by 30% and 70%, flashes become 70% fewer and disappear, respectively; faster ascent promotes positive cloud-to-ground (+CGs) flashes. Since cloud base is too cold (1°C) for coalescence, cloud condensation nucleus aerosol concentrations do not influence the lightning appreciably. The electrical response to varying concentrations of active ice nuclei is limited by most ice particles being secondary and less sensitive—a natural “buffer.” Imposing a maritime sounding suggests that the land–sea contrast in lightning for such storms is due to the vertical structure of environmental temperature and humidity. Weak CAPE, and both entrainment and condensate weight from a low cloud base, suppress ascent and charging. Maritime thermodynamic conditions reduce simulated flash rates by two orders of magnitude. Reducing aerosol loadings from continental to maritime only slightly reinforces this suppression. Last, a conceptual model is provided for how any simulated storm is either normal because graupel/hail is mostly positively charged or else is inverted/anomalous because graupel/hail is mostly negatively charged, with environmental factors controlling the charging. Impacts from microphysical processes, including three processes of secondary ice production, on lightning are analyzed.
-
Abstract We relate the spatial and temporal distribution of lightning flash rates and cloud top brightness temperature (CTBT) to concentric atmospheric gravity wave (CGW) events observed at the Southern Space Observatory (SSO) in São Martinho da Serra (29.44°S, 53.82°W, 488.7 m) in southern Brazil. The selected identified cases from 2017 to 2018 were observed by a hydroxyl (OH) all‐sky imager. Backward ray tracing shows that the time of gravity wave excitation agrees with the highest values of lightning flash rates (indicating lightning jump) as well as the coldest brightness temperatures that indicate the time of convective overshoot. Radiosonde measurements show high convective available potential energy (CAPE), associated with a maximum updraft velocity just prior to the wave events. We find that these possible source locations correspond to the positions and times that convective plumes overshot the tropopause (seen in GOES‐16 CTBT images). We also show that higher spatial lightning density (i.e., number of lightning flashes at a given longitude and latitude) agree with the overshoot locations from the GOES satellite. We also find that the overshoot times from the GOES‐16 satellite agree with the times lightning jumps were observed in the lightning flash rate. Finally, we find that the periodicities in the lightning flash rate agree with the periods of the observed CGWs, which further strengthens the result that the CGWs were excited by the deep convective systems determined from backward ray tracing.